Plan Review Notes For Permit 00040982 |
Permit Number |
00040982 |
|
Review Stop |
R |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2001-01-08 00:00:00 | | | **************UNSAT********************* | | | | SBC 104.2.2 | | | | 1)PROVIDE SOIL REPORT | | | | 2)PROVIDE MANUEL J FORM | | | | 3)PROVIDE DESIGN PRESSURES ON ALL | | EXTERIOR OPENINGS | | | | 4)PROVIDE DESIGN CERTIFICATION FOR | | BUILDING CODE COMPLIANCE | | | | 5)PROVIDE 2 CURRENT COMPLETE COPIES OF | | SBCCI OR METRO DADE PRODUCT APPROVALS | | FOR: | | EXTERIOR LVR DOOR UNIT | | BATHROOM WINDOWS | | .50 ALUMINUM STORM PANELS | | | | 6)PROVIDE INSTALLATION SCHEDULE AND KEY | | PLAN WITH SPECIFIC ANCHORS TO BE USED | | FOR ALL STORM PANELS | | | | 7)PROVIDE LENGHT OF J BOLTS FOR LEDGER | | ON 2ND FLOOR FRAMING | | | | 8)PROVIDE DETAILS FOR PORCH RAILINGS | | | | 9)PROVIDE STAIR SECTION DETAILS WITH | | TREAD,RISER,HANDRAIL,GUARDRAIL | | DIMENSIONS SBC 1006,1007,1015 | | | | 10)PROVIDE ATTIC ACCESS AND VENTILATION | | SBC 2309.6, 2309.7 | | | | 11)TYPE OF CONSTRUCTION DOES NOT COMPLY | | WITH SBC TBL 500,BUILDING EXCEEDS | | 2 STORIES, REVISE TO COMPLY | | | | 12)BEFORE A PERMIT TO CONSTRUCT CAN BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH CO., THE PERMIT PLANS STAMPED BY | | THEM AND THE RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. |
|