Plan Review Notes
Plan Review Notes For Permit 00031715
Permit Number 00031715
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". WILL NEED ELEVATION
 CERTIFICATE.
 -LOWEST FLOOR ELEVATION TO BE NO LESS
 THAN 18" ABOVE THE CROWN OF THE ROAD.
 SEC. 3107.1.1 CITY AMENDMENTS.
 2-CLEARLY INDICATE AREAS TO HAVE SAFETY
 GLASS. SEE PLANS FOR COMMENTS.
 SECTION 2405.2 SBC 1997.
 3-CLARIFY WINDOW SIZE FOR BEDROOMS #2
 AND #3. WHAT IS A SH 34+4?. WINDOW TO
 HAVE MINIMUM 24" CLEAR HEIGHT OPENING.
 SECTION 1005.4 SBC 1997.
 4-DESIGN CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM:
 -ENGINEER WHO SEALED THIS FORM TO SEAL
 THE STRUCTURAL DRAWINGS TOO.
 -REVISE MEAN ROOF HEIGHT. 16'-0" PLUS
 OR MINUS. MEAN ROOF HEIGHT IS TAKEN
 FROM GRADE, NOT FROM FINISH FLOOR, TO
 THE AVERAGE POINT OF THE HIGHEST ROOF.
 5-REVISE/UPDATE DRAWINGS. SEE COMMENTS
 ON PLANS.
 6-SOIL TEST REPORT TO HAVE ORIGINAL
 SIGNATURE AND DATE WHEN THE DOCUMENT
 WAS SEALED BY THE ENGINEER.
 7-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITHOUT SIDELITES AND WITH
 LEGIBLE DRAWINGS.
 8-PROVIDE COPIES OF TEST REPORTS FOR
 SLIDING GLASS DOORS AS PER ASTM E-330.
 SECTION 1706 SBC 1997.
 -PROFESSIONAL OF RECORD TO WRITE JOB
 LOCATION FOR SITE SPECIFIC PRODUCT
 APPROVAL FOR DOORS AND WINDOWS BY
 NORANDEX. ASLO, CLEARLY INDICATE WHICH
 WINDOW TYPE AND SIZE ARE GOING TO BE
 USED ON THIS PROJECT.
 -PROFESSIONAL OF RECORD TO CLEARLY
 PROVIDE NAME, ADDRESS, LICENSE NUMBER
 AND TELEPHONE NUMBER ON THIS PRODUCT
 APPROVAL.
 9-STORM PANELS:
 -CLEARLY INDICATE FASTENING METHOD AND
 ANCHOR TYPE AND SPACING TO BE USED ON
 THIS PROJECT ACCORDING TO THE DESIGN
 PRESSURES, STORM PANEL SPAN, EDGE
 DISTANCE AND BUILDING CONSTRUCTION
 (MASONRY CONSTRUCTION).


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved