Plan Review Notes
Plan Review Notes For Permit 00031561
Permit Number 00031561
Review Stop R
Sequence Number 3
Notes
Date Text
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "AO". WILL NEED TO PROVIDE
 AN ELEVATION CERTIFICATE.
 2-REVISE AGAIN THE ATTIC ACCESS PANEL
 SIZE. MINIMUM SIZE IS 22"X36" AS PER
 SECTION 2309.6 SBC 1997.
 3-UPDATE/REVISE DRAWINGS AS REQUIRED:
 -PROVIDE REAR ELEVATION AND FLOOR PLAN
 THAT MATCH TABLE 600 CALCULATIONS.
 REAR ELEVATION ON SHEET A-3 AND FLOOR
 PLAN ON SHEET A-8 DON'T MATCH. ALSO,
 REVISE SIZE OF SLIDING GLASS DOORS ON
 SHEET A-8 PARTIAL FLOOR PLAN.
 4-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE, BUT PLEASE MAKE
 SURE DRAWINGS ARE LEGIBLE TO AVOID
 UNNECESSARY RETURNS.
 5-SLIDING GLASS DOORS BY NORANDEX:
 PROVIDE COPIES OF TESTS RESULTS DONE
 AS PER ASTM E-330.
 SECTION 1706 SBC 1997.