2001-01-08 00:00:00*****************PROVISO****************
  
 SUBMIT SIGNED AND SEALED WATER AND
 SANITARY RISER DIAGRAMS FOR REVIEW.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 DRINKING FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3.(10)(A).PROVISIONS SHALL BE
 MADE FOR PEOPLE WHO HAVE TROUBLE BENDING
 OR STOOPING.
  
 BATHROOM ON 2ND.FLR SHALL BE ADAPTABLE.
 SHOW FIXTURE CLEARANCE OF WATER CLOSET
 (18"REQD.TO CENTER FROM WALL AND LAV.)
  
 SIZE OF SHOWER SHALL COMPLY W/FACBC
 SEC.4.21.2,AND HEIGHT OF CONTROLS SHALL
 COMPLY W/FACBC SEC.4.21.5
  
 SUBMIT DETAILS OFBLOCKING FOR FUTURE
 INSTALLATION OF GRAB BARS AND SEAT PER
 FACBC SEC.4.1.3(11).
  
 SUBMIT ALL OF THE INFORMATION PRIOR TO
 PLUMBING INSPECTION.IF YOU HAVE ANY
 QUESTIONS I CAN BE REACHED AT
 561-659-8096,EXT.8377.TIMOTHY LARGE,
 PLUMBING PLANS EXAMINER.