Plan Review Notes
Plan Review Notes For Permit 00020363
Permit Number 00020363
Review Stop R
Sequence Number 1
Notes
Date Text
2001-01-08 00:00:00DENIED
  
 1)DESIGN COMPLIANCE FORM SPECIFIES A
 MEAN ROOF HEIGHT TO BE 15',I CALCULATE
 IT TO BE 24'10" CLARIFY & RECALCULATE
 ALL UPLIFTS,PROVIDE CORRECTED FORM.
 2)EXTERIOR DOOR AT GUEST SUITE DOES NOT
 COMPLY WITH EGRESS REQUIREMENTS.EGRESS
 DOORS SHALL BE OF THE SIDE SWINGING
 TYPE AND SHALL PROVIDE A CLEAR OPENING
 OF NOT LESS THAN 32". 97SBC-1012.1
 3)PROVIDE ENERGY CALCS.AND MANUAL J FOR
 MAIN HOUSE
 4)PLANS INDICATE 50GAL WATER HEATER FORM
 600A-97 & EPL DISPLAY CARD INDICATE
 30 GAL. WATER HEATER,CLARIFY
 5)PROVIDE PRODUCT APPROVALS FOR INSWING
 EXTERIOR DOOR AT GUEST SUITE
 6)PROVIDE PRODUCT APPROVALS FOR STORM
 PANELS
 7)PROVIDE SOIL BEARING TEST REPORT PRIOR
 TO FIRST INSPECTION