Plan Review Details - Permit 99121816
Plan Review Stops For Permit 99121816 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2000-08-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-08-02 |
Time |
18:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-08-02 |
Time |
18:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2000-08-08 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
2000-08-08 |
Time |
14:14 |
Rev Time |
1.00 |
Received By |
cthirben |
Date |
2000-08-08 |
Time |
14:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2000-08-04 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-08-04 |
Time |
07:10 |
Rev Time |
0.33 |
Received By |
tlarge |
Date |
2000-08-04 |
Time |
06:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
F |
Date |
2001-01-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-01-12 |
Time |
09:11 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2001-01-12 |
Time |
09:11 |
Sent To |
|
|
Notes |
2001-01-12 00:00:00 | TRUSSES CHECKLIST: | | 1-WHERE IS THE ENGINEERING FOR THE | | PARALAM BEAM? | | 2-TRUSS DRAWINGS GENERAL DETAILS AND | | SPECIFICATIONS PACKAGE NEED TO BE | | COORDINATED AND UPDATED. THERE ARE | | DETAILS AND SPECS THAT ARE TOO OLD AND | | REFERENCING OLD CODES. | | -WHY IS ENGINEER SIGNING AND SEALING | | DOCUMENTS WITH THE NAME OF ANOTHER | | ENGINEER? | | -ENGINEER TO COMPLY WITH CHAPTER 471 | | FL. STATUTES WHEN SUBMITTING ANY | | INFORMATION FOR PUBLIC RECORDS. | | 3-SUPPORT REPORT INDICATES THAT TRUSSES | | WERE DESIGNED USING SBC 1991. | | | | | | | | | | JULIO GOMEZ, BUILDING PLAN EXAMINER, | | EXT. 8232. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2000-08-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2000-08-30 |
Time |
07:53 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PROVISO | | | | PROVIDE FLOOD ELEVATION CERTIFICATE |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2000-08-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2000-08-02 |
Time |
14:43 |
Rev Time |
3.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | DENIED | | | | 1)ADDITIONAL IMPACT FEES ARE OWED TO THE | | COUNTY FOR THE ADDITIONAL 268 SQFT UNDER | | A/C WHEN LOFT OPTION IS USED AS | | INDICATED ON PLANS. PLANS MUST BE RE- | | STAMPED BY COUNTY. | | | | 2)PROVIDE FOR REQUIRED FIRE CUT PER 1997 | | SBC SEC.2305.4 FOR FLOOR TRUSSES ENTER- | | ING AND TERMINATING IN MASONRY WALLS.SEE | | SHEET A-5. | | | | 3)SUBMIT 2 COPIES OF REVISED STORM PANEL | | KEY PLAN AND SCHEDULE THAT CORRESPONDS | | TO THE OPTIONS THAT ARE TO BE USED. | | | | 4)SPECIFICATIONS FOR GARAGE DOOR | | SUBMITTED WITH PRODUCT APPROVAL INDICATE | | A NEGATIVE DESIGN PRESSURE OF -33PSF FOR | | 16'X 7' DOOR, WIND LOADS ON SHEET A-4A | | LISTS NEG. PRESSURE OF -34PSF. | | PLEASE CORRECT. | | | | 5)PROVIDE 2 CURRENT COPIES OF METRO-DADE | | OR SBCCI PRODUCT APPROVALS FOR EXTERIOR | | OUTSWING STEEL DOOR WITH SIDELITES AS | | SHOWN ON PLANS. PRODUCT APPROVALS ARE | | REQUIRED FOR SPECIFIC COMPONENT THAT | | WILL BE INSTALLED. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2000-06-20 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2000-06-20 |
Time |
15:11 |
Rev Time |
0.50 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PER TM 6/19/00 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-02-10 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
2000-02-10 |
Time |
15:53 |
Rev Time |
0.25 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|