Plan Review Details - Permit 99121816
Plan Review Stops For Permit 99121816
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-08-02 Cont ID  
Sent By dpalmer Date 2000-08-02 Time 18:38 Rev Time 0.00
Received By dpalmer Date 2000-08-02 Time 18:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-08-08 Cont ID  
Sent By cthirben Date 2000-08-08 Time 14:14 Rev Time 1.00
Received By cthirben Date 2000-08-08 Time 14:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-08-04 Cont ID  
Sent By tlarge Date 2000-08-04 Time 07:10 Rev Time 0.33
Received By tlarge Date 2000-08-04 Time 06:51 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2001-01-12 Cont ID  
Sent By jgomez Date 2001-01-12 Time 09:11 Rev Time 0.50
Received By jgomez Date 2001-01-12 Time 09:11 Sent To  
Notes
2001-01-12 00:00:00TRUSSES CHECKLIST:
 1-WHERE IS THE ENGINEERING FOR THE
 PARALAM BEAM?
 2-TRUSS DRAWINGS GENERAL DETAILS AND
 SPECIFICATIONS PACKAGE NEED TO BE
 COORDINATED AND UPDATED. THERE ARE
 DETAILS AND SPECS THAT ARE TOO OLD AND
 REFERENCING OLD CODES.
 -WHY IS ENGINEER SIGNING AND SEALING
 DOCUMENTS WITH THE NAME OF ANOTHER
 ENGINEER?
 -ENGINEER TO COMPLY WITH CHAPTER 471
 FL. STATUTES WHEN SUBMITTING ANY
 INFORMATION FOR PUBLIC RECORDS.
 3-SUPPORT REPORT INDICATES THAT TRUSSES
 WERE DESIGNED USING SBC 1991.
  
  
  
  
 JULIO GOMEZ, BUILDING PLAN EXAMINER,
 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-08-30 Cont ID  
Sent By rmcdouga Date 2000-08-30 Time 07:53 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO
  
 PROVIDE FLOOD ELEVATION CERTIFICATE

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-08-02 Cont ID  
Sent By rmcdouga Date 2000-08-02 Time 14:43 Rev Time 3.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)ADDITIONAL IMPACT FEES ARE OWED TO THE
 COUNTY FOR THE ADDITIONAL 268 SQFT UNDER
 A/C WHEN LOFT OPTION IS USED AS
 INDICATED ON PLANS. PLANS MUST BE RE-
 STAMPED BY COUNTY.
  
 2)PROVIDE FOR REQUIRED FIRE CUT PER 1997
 SBC SEC.2305.4 FOR FLOOR TRUSSES ENTER-
 ING AND TERMINATING IN MASONRY WALLS.SEE
 SHEET A-5.
  
 3)SUBMIT 2 COPIES OF REVISED STORM PANEL
 KEY PLAN AND SCHEDULE THAT CORRESPONDS
 TO THE OPTIONS THAT ARE TO BE USED.
  
 4)SPECIFICATIONS FOR GARAGE DOOR
 SUBMITTED WITH PRODUCT APPROVAL INDICATE
 A NEGATIVE DESIGN PRESSURE OF -33PSF FOR
 16'X 7' DOOR, WIND LOADS ON SHEET A-4A
 LISTS NEG. PRESSURE OF -34PSF.
 PLEASE CORRECT.
  
 5)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 OUTSWING STEEL DOOR WITH SIDELITES AS
 SHOWN ON PLANS. PRODUCT APPROVALS ARE
 REQUIRED FOR SPECIFIC COMPONENT THAT
 WILL BE INSTALLED.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-06-20 Cont ID  
Sent By lsmith Date 2000-06-20 Time 15:11 Rev Time 0.50
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00PER TM 6/19/00

Review Stop Z ZONING
Rev No 1 Status P Date 2000-02-10 Cont ID  
Sent By gjoyce Date 2000-02-10 Time 15:53 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***