Plan Review Details - Permit 99121731
Plan Review Stops For Permit 99121731
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-02-12 Cont ID  
Sent By dpalmer Date 2000-02-12 Time 09:04 Rev Time 0.00
Received By dpalmer Date 2000-02-12 Time 09:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-02-01 Cont ID  
Sent By dpalmer Date 2000-02-01 Time 13:24 Rev Time 0.00
Received By dpalmer Date 2000-02-01 Time 13:24 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: NEED TO SUBMIT AIC RATING OF
 EQUIPMENT MAINS. NEEDS TO BE ABLE TO
 HANDLE AVAILABLE FAULT CURRENT. 110-9/
 230-65
  
 2)NOTE: NEED TO HAVE SMOKE DETECTORS
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 AS REQ`D BY NFPA-72 2-2.1.1.1
  
 3)NOTE: NEED TO SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECTE
 -D. AS REQ`D BY 210-8-A-6
  
 4)NOTE:PLEASE INCLUDE BLDG.STEEL AS PART
 OF THE GROUNDING ELECTRODE SYSTEM.
 AS PER 250-81
  
 NEED TO SUBMIT ALL THE ABOVE INFORMATION
 FOR REIVEW AND APPROVAL.IF THERE ARE ANY
 QUESTIONS PLEASE CALL 659-8096 X 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-01-22 Cont ID  
Sent By jleech Date 2000-01-22 Time 09:36 Rev Time 0.50
Received By jleech Date 2000-01-22 Time 09:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-01-13 Cont ID  
Sent By tlarge Date 2000-01-13 Time 07:05 Rev Time 0.50
Received By tlarge Date 2000-01-13 Time 07:05 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
 SANITARY RISER DOESN'T MATCH FLOOR PLAN.
 SUBMIT NEW RISER DIAGRAM PRIOR TO RGH.
 PLBG.INSP.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-02-25 Cont ID  
Sent By fknapp Date 2000-02-25 Time 11:33 Rev Time 1.00
Received By fknapp Date 2000-02-25 Time 11:32 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-02-15 Cont ID  
Sent By fknapp Date 2000-02-15 Time 08:11 Rev Time 4.00
Received By fknapp Date 2000-02-14 Time 15:27 Sent To  
Notes
2001-01-08 00:00:00 
 ****************DENIED******************
  
 SBC 104.2.2
  
 1)PROVIDE SOIL TEST REPORT
  
 2)PROVIDE RAISE SEAL OF DESIGN
 PROFESSIONAL ON PRODUCT APPROVAL
 SUBMITTAL FORMS
  
 3)PROVIDE 32" CLEAR OPENING AT FRONT
 ENTRY DOOR 1997 SBC 1012.1.1
  
 4)PROVIDE PRODUCT APPROVAL FOR FRONT
 DOOR ASSEMBLY BEING USED
  
 5)BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO., THE PERMIT PLANS STAMPED BY
 THEM AND THE RECIEPT ATTACHED TO THE
 PERMIT APPLICATION

Review Stop Z ZONING
Rev No 1 Status P Date 2000-01-11 Cont ID  
Sent By gjoyce Date 2000-01-11 Time 09:18 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***