Plan Review Details - Permit 99121678
Plan Review Stops For Permit 99121678 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-02-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-02-12 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-02-12 |
Time |
09:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2000-02-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-02-01 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-02-01 |
Time |
11:53 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ************** UNSAT ******************* | | | | 1)NOTE: NEED TO SUBMIT AIC RATING OF | | EQUIPMENT AND NEEDS TO BE ABLE TO HANDLE | | THE AVAILABLE FAULT CURRENT. | | | | 2)NOTE: SMOKE DETECTORS INSIDE AND OUT- | | -SIDE ALL SLEEPING ROOMS. | | | | 3)NOTE: NEED TO HAVE CIRCUT FOR BATH(S) | | LISTED ON PANEL SCHEDULE AS PER 210-52D | | 20 AMP AND #12 AWG. | | | | NEED TO SUBMIT ALL THE ABOVE INFORMATION | | FOR REVIEW AND APPROVAL. IF THERE ARE | | ANY QUESTIONS PLEAS CALL 659-8096 EXT- | | 8372 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2000-01-22 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2000-01-22 |
Time |
10:08 |
Rev Time |
0.35 |
Received By |
jleech |
Date |
2000-01-22 |
Time |
10:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2000-01-13 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-01-13 |
Time |
09:45 |
Rev Time |
0.33 |
Received By |
tlarge |
Date |
2000-01-13 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2000-02-25 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-02-25 |
Time |
11:00 |
Rev Time |
1.00 |
Received By |
fknapp |
Date |
2000-02-25 |
Time |
11:00 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED WITH PROVISO |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2000-02-15 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-02-15 |
Time |
12:44 |
Rev Time |
4.00 |
Received By |
fknapp |
Date |
2000-02-15 |
Time |
08:37 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | | | ****************DENIED****************** | | | | SBC 104.2.2 | | | | 1)PROVIDE SOIL TEST REPORT | | | | 2)PROVIDE RAISE SEAL OF DESIGN | | PROFESSIONAL ON PRODUCT APPROVAL | | SUBMITTAL FORMS | | | | 3)PROVIDE 32" CLEAR OPENING AT FRONT | | DOOR 1997 SBC 1012.1.1 | | | | 4)PROVIDE PRODUCT APPROVAL FOR FRONT | | DOOR ASSEMBLY BEING USED | | | | 5)PROVIDE PICKETS IN GUARDRAILS THAT A | | 4" SPHERE CANNOT PASS THRU 97 SBC 1015.3 | | | | 6)PROVIDE 1 HR FIRE RATING AT GLASS | | BLOCK OPENING ON 2ND FLOOR | | | | 7)BEFORE A PERMIT TO CONSTRUCT CAN BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH CO., THE PERMIT PLANS STAMPED BY | | THEM AND THE RECIEPT ATTACHED TO THE | | PERMIT APPLICATION |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-01-11 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
2000-01-11 |
Time |
09:22 |
Rev Time |
0.25 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|