2001-01-08 00:00:00 | PASSED WITH THE FOLLOWING PROVISOS: |
| 1.PARKING LOT CAN NOT BE BUILT UNTIL |
| THE UNDERGROUND UTILITY PLAN IS APPROVED |
| FOR WATER, SANITARY AND STORM WATER. |
| |
| 2.NO STORMWATER PLAN HAS BEEN APPROVED |
| AND ALL OF THE FOLLOWING ITEMS NEED TO |
| BE ADDRESSED; |
| |
| A. CONSTRUCTION PLANS |
| |
| B. DETAILS AND SPECIFICATIONS |
| |
| C. HYDRAULIC COMPUTATIONS AND SUPPORTING |
| DOCUMENTATION |
| |
| D. IMPERVIOUS AREA COMPUTATIONS |
| |
| E. POLLUTION PREVENTION PLAN.THE |
| POLLUTION PREVENTION PLAN SHALL BE KEPT |
| ON SITE AT ALL TIMES DURING |
| CONSTRUCTION. THE PLAN SHALL BE |
| INSTALLED IN THE FIELD PRIOR TO ANY |
| EARTHWORK. THE ENGINEER OF RECORD SHALL |
| CERTIFY TO THE CITY, ON A MONTHLY BASIS, |
| THAT THE PLAN IS WORKING PROPERLY AND AS |
| DESIGNED. THE ENGINEER OF RECORD IS |
| RESPONSIBLE TO CERTIFY IMPLEMENTATION OF |
| THE PROVISIONS OF CITY ORDINANCE NO. |
| 3132-98 OF THE CITY CODE AT SUCH TIME |
| THE PERMITTEE APPLIES FOR A CERTIFICATE |
| OF OCCUPANCY FROM THE CITY BUILDING |
| OFFICIAL |
| |
| F. EVERY SIX MONTHS AFTER CONSTRUCTION A |
| PE SHALL CERTIFY THAT THE PERMANENT |
| POLLUTION PREVENTION STRUCTURES, DRY-WET |
| WATER DETENTION FACILITIES, AND |
| EXFILTRATION SYSTEMS ARE WORKING AS |
| DESIGNED AND ARE IN GOOD OPERATING |
| CONDITION. ALL CERTIFICATIONS MUST BE |
| SUBMITTED TO: |
| STORM WATER UTILITY ENGINEER |
| CITY OF WEST PALM BEACH PUBLIC UTILITIES |
| DEPARTMENT |
| P.O. BOX 3366, WEST PALM BEACH, FL |
| 33402. |
| |
| THE CERTIFICATION MUST INCLUDE THE |
| BUILDING PERMIT NUMBER, THE ADDRESS OF |
| THE PROPERTY AND THE NAME OF THE |
| ESTABLISHMENT/PROJECT CONSTRUCTED. |
| |
| 3. SHEETS A-1, A-1.1, P2.1 AND SHEET 1 |
| OF 2 OF THE FIRE SPRINKLER PLAN SHOW THE |
| BACKFLOW LOCATION FOR THE FIRE SPRINKLER |
| SYSTEM AT THE BUILDING (SOUTHWEST |
| CORNER).THIS IS INCORRECT, IT WILL BE |
| PLACED AT THE WEST PROPERTY LINE AS |
| SHOWN ON THE UNDERGROUND UTILITY PLAN |
| SUPPLIED BY SIMMONS AND WHITE (SEE |
| ATTACHED). |
| |
| 4.DETAIL FOR THE DCDA ON THE FIRE |
| SPRINKLER DRAWING (1 OF 2) DOES NOT SHOW |
| AN ELEVATION ABOVE THE FLOOD PLAIN OR |
| GROUND ELEVATION.IT MUST BE PER THE |
| CITY DETAIL SHOWN ON THE UNDERGROUND |
| PLAN BY SIMMONS AND WHITE. |
| |
| 5.ON SHEET P2.2 THE SANITARY SEWER |
| PIPING EXITS THE NORTH SIDE OF THE |
| BUILDING NEAR "K4".WHILE THE |
| UNDERGROUND PLAN BY SIMMONS AND WHITE |
| SHOWS THE LATERAL ENTERING THE BUILDING |
| ON THE EAST SIDE NEAR "H5".YOU NEED TO |
| COORDINATE THIS DESIGN AND WORK SINCE IT |
| WILL BE INSTALLED PER THE SIMMONS AND |
| WHITE PLAN. |
| |
| 6.ON SHEET P2.2 AN 1-1/2" METER IS |
| SHOWN TO BE PLACED AT THE NORTHEAST |
| CORNER OF THE BUILDING WITH THE 2" PIPE |
| ENTERING THE BUILDING AT "K5".ON THE |
| UNDERGROUND PLAN BY SIMMONS AND WHITE |
| (SEE ATTACHED) SHOW THE WATER METER AT |
| THE SOUTHWEST CORNER OF THE PROPERTY |
| WITH THE WATER LINE ENTERING THE |
| BUILDING AT "A3.1" ON SHEET P2.1.YOU |
| NEED TO COORDINATE THIS DESIGN AND WORK |
| SINCE IT WILL BE INSTALLED PER THE |
| SIMMONS AND WHITE PLAN. |