Plan Review Stops For Permit 99121523 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2000-11-02 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-11-02 |
Time |
14:45 |
Rev Time |
1.00 |
Received By |
drunnels |
Date |
2000-11-02 |
Time |
14:45 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PROVISO | | 1. POOL EQUIPMENT BUILDING SHALL BE | | SIZED TO MEET ALL CLEARANCE REQUIREMENTS | | FOR EQUIPMENT INSTALLED. | | 2.POOL, FOUNTIAN,WALLS AND FENCES | | REQUIRE SEPERATE PERMITS | | 3. POOL GATE LATCH SHALL COMPLY WITH THE | | CITY OF WEST PALM BEACH POOL CODE | | SECTION 42 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2000-10-20 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-10-20 |
Time |
10:17 |
Rev Time |
1.00 |
Received By |
drunnels |
Date |
2000-10-20 |
Time |
10:17 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1. SHEET A-38 POOL EQUIPMENT BUILDING | | SHALL BE SIZED TO MEET ALL CLEARANCE | | REQUIREMENTS FOR EQUIPMENT INSTALLED. | | 2. SHEET A-38 ENTRANCE FROM SERVICE | | ALLEY NOT HANDICAP ACCESSABLE. | | REQUIRED AS THIS IS THE ONLY OFF SITE | | ACCESS POINT TO POOL CABANA AREA. | | 3.PRODUCT APPROVAL ON DOOR EXPIRED | | 10/13/98 SUBMIT CURRENT APPROVALS | | NOTE | | SHEET A-38 POOL, FOUNTIAN, WALLS AND | | FENCES REQUIRE SEPERATE PERMITS. | | SHEET A-38 POOL GATE LATCH SHALL COMPLY | | WITH THE CITY OF WEST PALM BEACH POOL | | CODE SECTION 42. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2000-07-01 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-07-01 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
bstaples |
Date |
2000-07-12 |
Time |
14:25 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISION 7/1/00 | | ITEMS 1, 5, AND 9 FROM PRIOR REVIEW NOT | | ADDRESSED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2000-02-14 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-02-14 |
Time |
10:05 |
Rev Time |
3.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1. PRODUCT APPROVALS FOR ROOFING AND | | DOORS NOT SUBMITTED. | | 2. TRUSS DRAWINGS NOT SUBMITTED. | | 3. SHEET A-1 INDICATES BUILDING TYPE VI | | CONSTRUCTION SEE 1997 SBC APPENDIX F FOR | | BUILDINGS LOCATED IN FIRST FIRE DISTRICT | | BUILDING MUST BE TYPE V ONE HOUR CONST. | | 4. SHEET A-38 ENTRANCE FROM SERVICE | | ALLEY NOT HANDICAPPED ACCESSABLE. | | REQUIRED AS THIOS IS THE ONLY OFF SITE | | ACCESS POINT TO POOL CABANA AREA. | | 5. SHEET A-38 HEALTH DEPARTMENT TO | | REVIEW AND APPROVE PLANS. | | 6. SHEET A-38 POOL EQUIPMENT BUILDING | | SHALL BE SIZED TO MEET ALL CLEARANCE | | REQUIREMENTS FOR EQUIPMENT INSTALLED. | | 7. SHEET A-38 POOL, FOUNTIAN, WALLS AND | | FENCES REQUIRE SEPERATE PERMITS. | | 8. SHEET A-38 POOL GATE LATCH SHALL | | COMPLY WITH CITY OF WEST PALM BEACH | | POOL CODE SECTION 42. | | 9. SHEET A-39 PROVIDE SPECIAL INSPECTOR | | AS PER PLAN NOTES. | | 10. ROOF NOTES, DESIGN IS TO ASCE 7-93, | | 1997 SBC REQUIRES DESIGN TO COMPLY WITH | | ASCE 7-95. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2000-02-28 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2000-02-28 |
Time |
08:26 |
Rev Time |
1.30 |
Received By |
jleahy |
Date |
2000-02-28 |
Time |
08:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2000-02-11 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-02-11 |
Time |
08:05 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED BY MIKE CARSILLO SEE NOTES ON | | PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2000-07-12 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
2000-07-12 |
Time |
14:26 |
Rev Time |
1.00 |
Received By |
cthirben |
Date |
2000-07-12 |
Time |
14:26 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NOTES:********************************** | | PERMIT FOR CABANA/POOL ONLY, NO A/C IN | | REVIEWED AREA. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2000-07-01 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
2000-07-01 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
cthirben |
Date |
2000-07-01 |
Time |
12:11 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | UNSATISFACTORY:************************* | | NO MECHANICAL COMMENTS ADDRESSED AS | | REVIEWED ON 02.14.00 BY NCD. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2000-02-14 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-02-14 |
Time |
15:53 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2000-02-14 |
Time |
15:53 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ***************DENIED******************* | | INSUFFICIENT INFORMATION INCLUDED FOR | | REVIEW. PROVIDE INFORMATION ON ANY MECH | | SYSTEM FOR THIS PROJECT INCLUDING BATH- | | ROOM VENTILATION PER ASHRAE 62-89 AND | | 1997 SMC |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2000-07-02 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-07-02 |
Time |
09:01 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
2000-07-02 |
Time |
08:37 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PROVISO: WATER SUPPLY CONTROL SHALL | | COMPLY W/SPC610.4.1,610.4.2. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2000-02-26 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-02-26 |
Time |
05:42 |
Rev Time |
1.50 |
Received By |
tlarge |
Date |
2000-02-26 |
Time |
05:42 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SHT.P-1-THE WATER SERVICE TO THE CABANA | | REQUIRES A BACKFLOW PREVENTION DEVICE. | | SPC SEC.606.1. | | | | THE DRINKING FOUNTAIN AT THE CABANA | | SHALL COMPLY W/FACBC SEC.4.1.3(10)(A) | | AND BE ON AN ACCESSIBLE ROUTE PER FACBC | | SEC.4.3.1. | | | | CLEARLY SHOW DIMENSIONS OF TOILET ROOMS. | | COMPLY W/FACBC SEC.4.16.2 AND FIG.28. | | | | SUBMIT COMPLETE POOL PLANS TO ENSURE | | COMPLIANCE W/DEPT.OF HEALTH CHAPT.64E-9. | | POOL PLANS SHALL BE REVIEWED AND | | APPROVED BY HEALTH DEPT.PRIOR TO REVIEW | | BY THIS DEPT.COUNTYWIDE AMENDMENTS TO | | SPC SEC.101.4.7. | | | | SUBMIT DETAILS FOR HANDICAP FIXTURES. | | (MOUNTING HEIGHTS,CLEAR FLOOR SPACE AT | | FIXTURES,ETC.). | | | | FLOOR AND WALLS IN CABANA SHALL BE | | NONABSORBENT TO A HEIGHT OF 4'PER SBC | | SEC.1204.2. | | | | POOL SHOWER SHALL COMPLY W/FACBC 4.21.6 | | (EXCEPTION)AND BE ON AN ACCESSIBLE | | ROUTE PER FACBC SEC.4.3.1. | | | | SHUTOFF VALVE REQD.ON WATER SERVICE PER | | SPC 610.1.AND WATER SUPPLY CONTROL FOR | | CABANA SHALL COMPLY W/SPC SEC.610.4.1, | | 610.4.2. | | | | DELETE OR VOID BLUEPRINTS NOT APPLICABLE | | TO THIS PERMIT.COUNTYWIDE AMENDMENTS TO | | SPC SEC.104.2.1. | | | | SEPARATE PERMIT REQD.FOR FOUNTAIN.COUNTY | | WIDE AMENDMENTS TO SPC SEC.104.1.1. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-11-06 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-02-11 |
Time |
08:06 |
Rev Time |
1.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | DENIED DENNIS CAMPBELL PENDING REPLAT |
|
|