Plan Review Details - Permit 99121523
Plan Review Stops For Permit 99121523
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2000-11-02 Cont ID  
Sent By drunnels Date 2000-11-02 Time 14:45 Rev Time 1.00
Received By drunnels Date 2000-11-02 Time 14:45 Sent To  
Notes
2001-01-08 00:00:00PROVISO
 1. POOL EQUIPMENT BUILDING SHALL BE
 SIZED TO MEET ALL CLEARANCE REQUIREMENTS
 FOR EQUIPMENT INSTALLED.
 2.POOL, FOUNTIAN,WALLS AND FENCES
 REQUIRE SEPERATE PERMITS
 3. POOL GATE LATCH SHALL COMPLY WITH THE
 CITY OF WEST PALM BEACH POOL CODE
 SECTION 42

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2000-10-20 Cont ID  
Sent By drunnels Date 2000-10-20 Time 10:17 Rev Time 1.00
Received By drunnels Date 2000-10-20 Time 10:17 Sent To  
Notes
2001-01-08 00:00:001. SHEET A-38 POOL EQUIPMENT BUILDING
 SHALL BE SIZED TO MEET ALL CLEARANCE
 REQUIREMENTS FOR EQUIPMENT INSTALLED.
 2. SHEET A-38 ENTRANCE FROM SERVICE
 ALLEY NOT HANDICAP ACCESSABLE.
 REQUIRED AS THIS IS THE ONLY OFF SITE
 ACCESS POINT TO POOL CABANA AREA.
 3.PRODUCT APPROVAL ON DOOR EXPIRED
 10/13/98 SUBMIT CURRENT APPROVALS
 NOTE
 SHEET A-38 POOL, FOUNTIAN, WALLS AND
 FENCES REQUIRE SEPERATE PERMITS.
 SHEET A-38 POOL GATE LATCH SHALL COMPLY
 WITH THE CITY OF WEST PALM BEACH POOL
 CODE SECTION 42.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-07-01 Cont ID  
Sent By bstaples Date 2000-07-01 Time 10:27 Rev Time 0.00
Received By bstaples Date 2000-07-12 Time 14:25 Sent To  
Notes
2001-01-08 00:00:00REVISION 7/1/00
 ITEMS 1, 5, AND 9 FROM PRIOR REVIEW NOT
 ADDRESSED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-02-14 Cont ID  
Sent By bstaples Date 2000-02-14 Time 10:05 Rev Time 3.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:001. PRODUCT APPROVALS FOR ROOFING AND
 DOORS NOT SUBMITTED.
 2. TRUSS DRAWINGS NOT SUBMITTED.
 3. SHEET A-1 INDICATES BUILDING TYPE VI
 CONSTRUCTION SEE 1997 SBC APPENDIX F FOR
 BUILDINGS LOCATED IN FIRST FIRE DISTRICT
 BUILDING MUST BE TYPE V ONE HOUR CONST.
 4. SHEET A-38 ENTRANCE FROM SERVICE
 ALLEY NOT HANDICAPPED ACCESSABLE.
 REQUIRED AS THIOS IS THE ONLY OFF SITE
 ACCESS POINT TO POOL CABANA AREA.
 5. SHEET A-38 HEALTH DEPARTMENT TO
 REVIEW AND APPROVE PLANS.
 6. SHEET A-38 POOL EQUIPMENT BUILDING
 SHALL BE SIZED TO MEET ALL CLEARANCE
 REQUIREMENTS FOR EQUIPMENT INSTALLED.
 7. SHEET A-38 POOL, FOUNTIAN, WALLS AND
 FENCES REQUIRE SEPERATE PERMITS.
 8. SHEET A-38 POOL GATE LATCH SHALL
 COMPLY WITH CITY OF WEST PALM BEACH
 POOL CODE SECTION 42.
 9. SHEET A-39 PROVIDE SPECIAL INSPECTOR
 AS PER PLAN NOTES.
 10. ROOF NOTES, DESIGN IS TO ASCE 7-93,
 1997 SBC REQUIRES DESIGN TO COMPLY WITH
 ASCE 7-95.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-02-28 Cont ID  
Sent By jleahy Date 2000-02-28 Time 08:26 Rev Time 1.30
Received By jleahy Date 2000-02-28 Time 08:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-02-11 Cont ID  
Sent By bstaples Date 2000-02-11 Time 08:05 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED BY MIKE CARSILLO SEE NOTES ON
 PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-07-12 Cont ID  
Sent By cthirben Date 2000-07-12 Time 14:26 Rev Time 1.00
Received By cthirben Date 2000-07-12 Time 14:26 Sent To  
Notes
2001-01-08 00:00:00NOTES:**********************************
 PERMIT FOR CABANA/POOL ONLY, NO A/C IN
 REVIEWED AREA.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2000-07-01 Cont ID  
Sent By cthirben Date 2000-07-01 Time 12:11 Rev Time 0.00
Received By cthirben Date 2000-07-01 Time 12:11 Sent To  
Notes
2001-01-08 00:00:00UNSATISFACTORY:*************************
 NO MECHANICAL COMMENTS ADDRESSED AS
 REVIEWED ON 02.14.00 BY NCD.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-02-14 Cont ID  
Sent By ndenmark Date 2000-02-14 Time 15:53 Rev Time 0.33
Received By ndenmark Date 2000-02-14 Time 15:53 Sent To  
Notes
2001-01-08 00:00:00***************DENIED*******************
 INSUFFICIENT INFORMATION INCLUDED FOR
 REVIEW. PROVIDE INFORMATION ON ANY MECH
 SYSTEM FOR THIS PROJECT INCLUDING BATH-
 ROOM VENTILATION PER ASHRAE 62-89 AND
 1997 SMC

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-07-02 Cont ID  
Sent By tlarge Date 2000-07-02 Time 09:01 Rev Time 0.50
Received By tlarge Date 2000-07-02 Time 08:37 Sent To  
Notes
2001-01-08 00:00:00PROVISO: WATER SUPPLY CONTROL SHALL
 COMPLY W/SPC610.4.1,610.4.2.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-02-26 Cont ID  
Sent By tlarge Date 2000-02-26 Time 05:42 Rev Time 1.50
Received By tlarge Date 2000-02-26 Time 05:42 Sent To  
Notes
2001-01-08 00:00:00SHT.P-1-THE WATER SERVICE TO THE CABANA
 REQUIRES A BACKFLOW PREVENTION DEVICE.
 SPC SEC.606.1.
  
 THE DRINKING FOUNTAIN AT THE CABANA
 SHALL COMPLY W/FACBC SEC.4.1.3(10)(A)
 AND BE ON AN ACCESSIBLE ROUTE PER FACBC
 SEC.4.3.1.
  
 CLEARLY SHOW DIMENSIONS OF TOILET ROOMS.
 COMPLY W/FACBC SEC.4.16.2 AND FIG.28.
  
 SUBMIT COMPLETE POOL PLANS TO ENSURE
 COMPLIANCE W/DEPT.OF HEALTH CHAPT.64E-9.
 POOL PLANS SHALL BE REVIEWED AND
 APPROVED BY HEALTH DEPT.PRIOR TO REVIEW
 BY THIS DEPT.COUNTYWIDE AMENDMENTS TO
 SPC SEC.101.4.7.
  
 SUBMIT DETAILS FOR HANDICAP FIXTURES.
 (MOUNTING HEIGHTS,CLEAR FLOOR SPACE AT
 FIXTURES,ETC.).
  
 FLOOR AND WALLS IN CABANA SHALL BE
 NONABSORBENT TO A HEIGHT OF 4'PER SBC
 SEC.1204.2.
  
 POOL SHOWER SHALL COMPLY W/FACBC 4.21.6
 (EXCEPTION)AND BE ON AN ACCESSIBLE
 ROUTE PER FACBC SEC.4.3.1.
  
 SHUTOFF VALVE REQD.ON WATER SERVICE PER
 SPC 610.1.AND WATER SUPPLY CONTROL FOR
 CABANA SHALL COMPLY W/SPC SEC.610.4.1,
 610.4.2.
  
 DELETE OR VOID BLUEPRINTS NOT APPLICABLE
 TO THIS PERMIT.COUNTYWIDE AMENDMENTS TO
 SPC SEC.104.2.1.
  
 SEPARATE PERMIT REQD.FOR FOUNTAIN.COUNTY
 WIDE AMENDMENTS TO SPC SEC.104.1.1.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-11-06 Cont ID  
Sent By bstaples Date 2000-02-11 Time 08:06 Rev Time 1.00
Received By sgraham Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED DENNIS CAMPBELL PENDING REPLAT