Plan Review Stops For Permit 99121248 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2000-09-14 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2000-09-14 |
Time |
08:38 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REV#3 5/1/00 S-3 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2000-03-13 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-02-08 |
Time |
09:08 |
Rev Time |
5.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SEE CHECK LIST ATTACHED TO PLANS | | REVISIONS REVIEWED 3/13/00 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-03-31 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2000-03-31 |
Time |
15:32 |
Rev Time |
2.00 |
Received By |
jleahy |
Date |
2000-03-31 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2000-01-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2000-01-07 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2000-02-10 |
Time |
13:56 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | E-1 SERVICE FOR "HE" IS MOUNTED ONUNIT | | TOWN HOUSE,MAINS TO BE GROUPED | | | | E-1 MORE THAN ONE SERVICE ON A BUILDING | | | | E-1 OUTLET OUTSIDE ON CABANA NOT SHOWN | | WITH GFCI PROTECTION | | | | E-1 PARKING GARAGE IS SHOWN WITH 2 ADD- | | TIONAL SERVICES.MAINS NOT GROUPED! | | | | E-1 110-16 FOR SERVICE EQUIPMENT | | WORKING SPACE IN FRONT OF ALL SERVIC | | EQUIPMENT!!!!!!!!!! |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2000-05-01 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-02-04 |
Time |
16:15 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SEE NOTES ON PLANS M. CARSILLO |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2000-12-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2000-12-28 |
Time |
16:21 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | A/C REVISION |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2000-03-09 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-03-09 |
Time |
06:52 |
Rev Time |
1.00 |
Received By |
ndenmark |
Date |
2000-03-09 |
Time |
06:52 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PRIOR ISSUES CORRECTED BY REVISIONS SEE | | REVISIONS AND COMMENT SHEETS |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2000-03-09 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
1999-12-28 |
Time |
08:40 |
Rev Time |
1.00 |
Received By |
ndenmark |
Date |
1999-12-28 |
Time |
08:40 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | CORRECTED BY REVISIONS3/9/00***** | | | | 1) SHT A-31 DETAIL 3 DRYER VENT AND BATH | | EXHAUST DUCT TO BE ENCLOSED IN SHAFT TO | | BOTTOM OF ROOF STRUCTURE | | 2) SHT A-31 DETAIL 2 DRYER VENT TO BE | | MIN. 4" NOT 3", DRYER VENT TO RUN FULL | | LENGTH OUT OF BUILDING | | 3) SHT A-31 DETAIL 4 INDICATE WHICH SIZE | | CAP TO BE USED- 4" OR 2 1/2" NOTE: FLEX | | METAL DUCT NOT ALLOWED BY CODE | | 4) SHT AC-1 AREAS WITH 300CFM OR GREATER | | REQUIRES RETURN AIR FROM AREA | | 5) SHT AC-1 PROVIDE MANUFACTURES SPEC'S | | ON CAPACITY TO PUSH LENGTH OF DUCT USED | | 6) ANY DUCT PENETRATING RATED CEILING | | TO HAVE FIRE DAMPERS PER 1997 SMC 610.2 | | 7) CONDENSING UNIT SERVICE TO BE PER NEC | | AND 1997 SMC 304.7.2 WHICHEVER IS GREAT- | | ER. DISCONNECT TO BE WITHIN 6' OF THE | | SERVICE SIDE OF THE EQUIPMENT AND A 115V | | GFIC OUTLET REQUIRED. | | 8) SHT AC 5 OVERFLOW PROTECTION REQUIRED | | FOR AHU'S PER 1997 SMC 304.8.6 | | 9) BATHROOM EXHAUST DUCT SHOWN PENETRAT- | | ING 2ND FL CONC. FLOOR SLAB ABOVE GARAGE | | PROVIDE DETAIL TO SHOW COMPLIANCE W/ SMC | | 610.2 AND 610.4. SHAFT ENCLOSUREREQ'D | | FOR FIRE PROTECTION OF ASSEMBLY. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2000-03-12 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-03-12 |
Time |
12:30 |
Rev Time |
1.25 |
Received By |
tlarge |
Date |
2000-03-12 |
Time |
12:15 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************PROVISO******************* | | PLUMBING-BUILDING 5D | | | | HORIZONTAL DRY VENTS NOT PERMITTED PER | | SPC SEC.906.2.1. | | | | ENERGY CALCS.NOTE EWH AS 65 GALS.AND | | WATER HEATER SCHEDULE ON SHT.P-7 NOTES | | 30 GAL.CLARIFY.FLA.ENERGY CODE SEC.103.2 | | | | SUBMIT COPIES OF PERMITS FROM DEPT. OF | | ENVIRONMENTAL PROTECTION (DEP) AND P.B. | | COUNTY HEALTH DEPT.FOR WATER AND SEWER | | MAINS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2000-01-11 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-01-11 |
Time |
11:22 |
Rev Time |
7.75 |
Received By |
tlarge |
Date |
2000-01-10 |
Time |
16:39 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SHT.P-1-THE WATER SERVICE TO THE CABANA | | DOESN'T APPEAR TO BE PROTECTED AGAINST | | BACKFLOW.COMPLY W/SPC SEC.606.1. | | | | DRINKING FOUNTAIN AT CABANA SHALL | | COMPLY W/FACBC SEC.4.1.3(10)(A). | | | | SHT.P-1.-SHOW DIMENSIONS OF TOILET ROOMS | | COMPLY W/FACBC SEC.4.16.2.AND FIG.28. | | | | SUBMIT NUMBER OF PERSONS THAT WILL BE | | UTILIZING THE CABANA AT ANY ONE TIME. | | COMPLY W/TABLE 407 OF SPC. | | | | SHT.P-2-CONDENSATE LINES ARE SHOWN AS | | 2" AND 1 1/4" CLARIFY. | | | | SHT.P-2-SUBMIT A SANITARY ISOMETRIC THAT | | IS LEGIBLE AND CLEARLY REFLECTS THE | | SCOPE OF THE INSTALLATION PER COUNTYWIDE | | AMENDMENTS TO SPC SEC.104.2.1. | | | | ENERGY CALCS.NOTE EWH AS 60 GALS.AND SHT | | P-1 NOTES 30 GAL.CLARIFY.FEC SEC.103.2. | | (SEE SHT.P-7) | | | | CONDENSATE DRAINS ON MULTIPLE STORY | | BUILDINGS SHALL BE VENTED WHERE 2 OR | | MORE UNITS ARE CONNECTED TO COMMON RISER | | PER COUNTYWIDE AMENDMENTS SEC.5. | | | | SUBMIT CONDENSATE RISER FOR REVIEW PER | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 | | | | SUBMIT IRRIGATION PLANS IF APPLICABLE & | | INDICATE WATER SUPPLY SOURCE FOR SYSTEM. | | A WATER USE PERMIT FROM SFWMD MAY BE | | REQD.PER F.S.373.219,373.62. | | | | CIVIL DRAWINGS SHALL BE SIGNED AND | | SEALED PER COUNTYWIDE AMENDMENTS TO SPC | | SEC.104.2.3.,F.S.471.025. | | | | NOTE:A SEPARATE PERMIT SHALL BE REQD.FOR | | THE POOL,FOUNTAIN,CABANA . |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-03-13 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-02-04 |
Time |
16:14 |
Rev Time |
0.10 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | DENIED DENNIS CAMPBELL RE-PLAT REQUIRED | | APPROVED 3/13/00 DENNIS CAMPBELL |
|
|