Plan Review Details - Permit 99121237
Plan Review Stops For Permit 99121237
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-03-14 Cont ID  
Sent By bstaples Date 2001-03-13 Time 11:44 Rev Time 1.00
Received By bstaples Date 2001-03-13 Time 13:33 Sent To  
Notes
2001-03-14 00:00:00OK PERMIT 01021101 ISSUED FOR AWNINGS.
2001-03-13 00:00:00IFORMATION ON FIRE PROTECTION OF
 AWNINGS REQUIRED. FIRE DEPARTMENT
 REVIEW REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-07-13 Cont ID  
Sent By bstaples Date 2000-07-13 Time 09:07 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-04-28 Cont ID  
Sent By bstaples Date 2000-04-28 Time 08:30 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:001. PLANS SUBMITTED 4/28/00 FIRST ROUTING
 2. NEED TO PAY IMPACT FEES.
 3. FLORIDA ENERGY SHEETS REC 6/30/00
 A. COMMERICAL TO BE SIGNED BY OWNE
 AGENT WITH TENNANT BUILD OUT OK
 B. RESIDENTAL TO BE SUBMITTED.
 REC 6/30/00
 PLANS PICKED UP FOR IMPACT FEE PAYMENT
 6/30/00.WRS

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2001-03-11 Cont ID  
Sent By dpalmer Date 2001-03-11 Time 14:01 Rev Time 0.00
Received By dpalmer Date 2001-03-11 Time 14:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-03-11 Cont ID  
Sent By dpalmer Date 2001-03-11 Time 14:01 Rev Time 0.00
Received By dpalmer Date 2001-03-11 Time 14:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-09-19 Cont ID  
Sent By dpalmer Date 2000-09-19 Time 18:12 Rev Time 0.00
Received By dpalmer Date 2000-09-19 Time 18:12 Sent To  
Notes
2001-01-08 00:00:00REV FOR STAIRWELL LIGHTING AND FIRE
 ALARM LOCATIONS ONLY.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-06-29 Cont ID  
Sent By jleahy Date 2000-06-29 Time 13:00 Rev Time 1.30
Received By jleahy Date 2000-06-29 Time 13:00 Sent To  
Notes
2001-01-08 00:00:00PAGES E6.01,E7.01

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-05-08 Cont ID  
Sent By dpalmer Date 2000-05-08 Time 14:02 Rev Time 0.00
Received By dpalmer Date 2000-05-08 Time 14:02 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT *****************
  
 1)NOTE: ON E-E6.01 YOU SHOW 'HP1' WITH
 A MAIN #3,#4?? YET ON SHEET E-E6.03
 YOU SHOW MAIN LUG ONLY FOR PANELS.,
 PLEASE CORRECT AND SUBMIT MORE DETAILS
 ON ELECTRICAL RISER AND PANEL SCHEDULES.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS CALL
 659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2000-09-28 Cont ID  
Sent By mcarsill Date 2000-09-27 Time 16:19 Rev Time 0.00
Received By mcarsill Date 2000-09-27 Time 16:19 Sent To  
Notes
2001-01-08 00:00:001) BUILDING ADDRESS NOT SHOWN ON
 ELEVATION DRAWINGS. BUILDING ADDRESS TO
 COMPLY WITH CITY CODE REQUIREMENTS.
 2) EXIT DOOR 101 AND 117 ARE NOT TO
 INTERFERE WITH ONE ANOTHER WHEN BOTH
 ARE OPENED.
 3) HANDRAILS AND GUARDS TO COMPLY WITH
 NFPA 101, THE LIFE SAFETY CODE, 1985
 EDTION.
 4) PROVIDE COMPLETE FIRE ALARM SYSTEM
 SHOP DRAWINGS AND CUT SHEETS FOR FIRE
 ALARM EQUIPMENT SHOWN ON DRAWINGS.
 5) ELEVATOR TO COMPLY WITH ANSI A17.1
 6) STAIRS TO COMPLY WITH NEW STAIR
 REQUIREMENTS IN NFPA 101, THE LIFE
 SAFETY CODE, 1985 EDITION.
 APPROVED PROVISO:

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-07-18 Cont ID  
Sent By drunnels Date 2000-07-18 Time 10:05 Rev Time 0.10
Received By drunnels Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO PER MC PHONE 7/18/00LS

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-05-15 Cont ID  
Sent By bstaples Date 2000-05-15 Time 15:36 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED 5/1/00 M. CARSILLO SEE NOTES
 ATTACHED.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-09-09 Cont ID  
Sent By ndenmark Date 2000-09-09 Time 08:14 Rev Time 0.33
Received By ndenmark Date 2000-09-09 Time 08:05 Sent To  
Notes
2001-01-08 00:00:00REVISIONS DATED 9/9/00 D-M3.01, M3.02,
 M3.03, M3.04, M3.05, AND M3.06 ACTUAL
 REVISION DRAWING DATE 8/31/00

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-07-18 Cont ID  
Sent By cthirben Date 2000-07-18 Time 09:00 Rev Time 1.00
Received By drunnels Date 2000-07-18 Time 08:59 Sent To  
Notes
2001-01-08 00:00:00PER CLYDE 7/18/00

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-05-22 Cont ID  
Sent By ndenmark Date 2000-05-22 Time 06:59 Rev Time 1.00
Received By ndenmark Date 2000-05-22 Time 06:59 Sent To  
Notes
2001-01-08 00:00:00**********PROVISO***********************
 1) 1997 SMC 505 AND NFPA 96 TO BE REFERE
 FOR COMPLIANCE WITH THE TENANT KITCHEN
 EXHAUST
 2) EXHAUST SHAFT TO BE FOR EXHAUST DUCT
 ONLY AND NOT USED FOR ANY OTHER PURPOSE
 3) EXHAUST DUCT TO HAVE CLEANOUT PROVIS-
 IONS AT EACH FLOOR AS WELL AS CHANGE OF
 DIRECTION

Review Stop P PLUMBING
Rev No 5 Status P Date 2000-09-13 Cont ID  
Sent By tlarge Date 2000-09-03 Time 17:55 Rev Time 1.50
Received By tlarge Date 2000-09-13 Time 17:54 Sent To  
Notes
2001-01-08 00:00:00REVISE SANITARY AND WATER LINES.

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-09-09 Cont ID  
Sent By tlarge Date 2000-09-09 Time 10:00 Rev Time 1.00
Received By tlarge Date 2000-09-09 Time 09:00 Sent To  
Notes
2001-01-08 00:00:00REVISE SANITARY,STORM AND WATER.

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-07-18 Cont ID  
Sent By pschmitz Date 2000-07-18 Time 08:42 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-07-12 Cont ID  
Sent By tlarge Date 2000-07-12 Time 15:35 Rev Time 1.25
Received By pschmitz Date 2000-07-12 Time 13:50 Sent To  
Notes
2001-01-08 00:00:00COMPLY W/ALL PREVIOUS COMMENTS

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-04-29 Cont ID  
Sent By tlarge Date 2000-04-29 Time 12:00 Rev Time 1.00
Received By pschmitz Date 2000-04-29 Time 11:58 Sent To  
Notes
2001-01-08 00:00:00SUBMIT DETAIL OF SCUPPERS.COMPLY W/
 APPENDIX "A",TABLE A101.2.
  
 SUBMIT COMPLETE STORM RISER DIAGRAM FOR
 REVIEW.SHOW SQ.FT.AREA DRAINED BY EACH
 DRAIN.COMPLY W/SPC SEC.1108.1,1108.2.
 SIZING SHALL INCUDE 1/2 TOTAL AREA OF
 PARAPET WALLS PER SPC SEC.1108.3.
  
 SIZING OF SECONDARY DRAINAGE SYSTEM
 SHALL COMPLY W/SPC SEC.1109.3.SUBMIT
 CALCULATIONS FOR REVIEW.
  
 INDICATE SLOPE OF STORM DRAINAGE PIPING
 ON PLANS.COMPLY W/TABLES 1108.1,1108.2.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-06-29 Cont ID  
Sent By gjoyce Date 2000-06-29 Time 10:43 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***