Plan Review Stops For Permit 99121237 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2001-03-14 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2001-03-13 |
Time |
11:44 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
2001-03-13 |
Time |
13:33 |
Sent To |
|
|
Notes |
2001-03-14 00:00:00 | OK PERMIT 01021101 ISSUED FOR AWNINGS. | 2001-03-13 00:00:00 | IFORMATION ON FIRE PROTECTION OF | | AWNINGS REQUIRED. FIRE DEPARTMENT | | REVIEW REQUIRED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2000-07-13 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-07-13 |
Time |
09:07 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2000-04-28 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-04-28 |
Time |
08:30 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1. PLANS SUBMITTED 4/28/00 FIRST ROUTING | | 2. NEED TO PAY IMPACT FEES. | | 3. FLORIDA ENERGY SHEETS REC 6/30/00 | | A. COMMERICAL TO BE SIGNED BY OWNE | | AGENT WITH TENNANT BUILD OUT OK | | B. RESIDENTAL TO BE SUBMITTED. | | REC 6/30/00 | | PLANS PICKED UP FOR IMPACT FEE PAYMENT | | 6/30/00.WRS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2001-03-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-03-11 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-03-11 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2001-03-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-03-11 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-03-11 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2000-09-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-09-19 |
Time |
18:12 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-09-19 |
Time |
18:12 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REV FOR STAIRWELL LIGHTING AND FIRE | | ALARM LOCATIONS ONLY. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-06-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2000-06-29 |
Time |
13:00 |
Rev Time |
1.30 |
Received By |
jleahy |
Date |
2000-06-29 |
Time |
13:00 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PAGES E6.01,E7.01 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2000-05-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-05-08 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-05-08 |
Time |
14:02 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | 1)NOTE: ON E-E6.01 YOU SHOW 'HP1' WITH | | A MAIN #3,#4?? YET ON SHEET E-E6.03 | | YOU SHOW MAIN LUG ONLY FOR PANELS., | | PLEASE CORRECT AND SUBMIT MORE DETAILS | | ON ELECTRICAL RISER AND PANEL SCHEDULES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS CALL | | 659-8096 EXT 8372 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2000-09-28 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2000-09-27 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2000-09-27 |
Time |
16:19 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1) BUILDING ADDRESS NOT SHOWN ON | | ELEVATION DRAWINGS. BUILDING ADDRESS TO | | COMPLY WITH CITY CODE REQUIREMENTS. | | 2) EXIT DOOR 101 AND 117 ARE NOT TO | | INTERFERE WITH ONE ANOTHER WHEN BOTH | | ARE OPENED. | | 3) HANDRAILS AND GUARDS TO COMPLY WITH | | NFPA 101, THE LIFE SAFETY CODE, 1985 | | EDTION. | | 4) PROVIDE COMPLETE FIRE ALARM SYSTEM | | SHOP DRAWINGS AND CUT SHEETS FOR FIRE | | ALARM EQUIPMENT SHOWN ON DRAWINGS. | | 5) ELEVATOR TO COMPLY WITH ANSI A17.1 | | 6) STAIRS TO COMPLY WITH NEW STAIR | | REQUIREMENTS IN NFPA 101, THE LIFE | | SAFETY CODE, 1985 EDITION. | | APPROVED PROVISO: |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2000-07-18 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-07-18 |
Time |
10:05 |
Rev Time |
0.10 |
Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PROVISO PER MC PHONE 7/18/00LS |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2000-05-15 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-05-15 |
Time |
15:36 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | DENIED 5/1/00 M. CARSILLO SEE NOTES | | ATTACHED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2000-09-09 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-09-09 |
Time |
08:14 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2000-09-09 |
Time |
08:05 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISIONS DATED 9/9/00 D-M3.01, M3.02, | | M3.03, M3.04, M3.05, AND M3.06 ACTUAL | | REVISION DRAWING DATE 8/31/00 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2000-07-18 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
2000-07-18 |
Time |
09:00 |
Rev Time |
1.00 |
Received By |
drunnels |
Date |
2000-07-18 |
Time |
08:59 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PER CLYDE 7/18/00 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2000-05-22 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-05-22 |
Time |
06:59 |
Rev Time |
1.00 |
Received By |
ndenmark |
Date |
2000-05-22 |
Time |
06:59 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **********PROVISO*********************** | | 1) 1997 SMC 505 AND NFPA 96 TO BE REFERE | | FOR COMPLIANCE WITH THE TENANT KITCHEN | | EXHAUST | | 2) EXHAUST SHAFT TO BE FOR EXHAUST DUCT | | ONLY AND NOT USED FOR ANY OTHER PURPOSE | | 3) EXHAUST DUCT TO HAVE CLEANOUT PROVIS- | | IONS AT EACH FLOOR AS WELL AS CHANGE OF | | DIRECTION |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2000-09-13 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-09-03 |
Time |
17:55 |
Rev Time |
1.50 |
Received By |
tlarge |
Date |
2000-09-13 |
Time |
17:54 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISE SANITARY AND WATER LINES. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2000-09-09 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-09-09 |
Time |
10:00 |
Rev Time |
1.00 |
Received By |
tlarge |
Date |
2000-09-09 |
Time |
09:00 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISE SANITARY,STORM AND WATER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2000-07-18 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2000-07-18 |
Time |
08:42 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2000-07-12 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-07-12 |
Time |
15:35 |
Rev Time |
1.25 |
Received By |
pschmitz |
Date |
2000-07-12 |
Time |
13:50 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | COMPLY W/ALL PREVIOUS COMMENTS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2000-04-29 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-04-29 |
Time |
12:00 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
2000-04-29 |
Time |
11:58 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SUBMIT DETAIL OF SCUPPERS.COMPLY W/ | | APPENDIX "A",TABLE A101.2. | | | | SUBMIT COMPLETE STORM RISER DIAGRAM FOR | | REVIEW.SHOW SQ.FT.AREA DRAINED BY EACH | | DRAIN.COMPLY W/SPC SEC.1108.1,1108.2. | | SIZING SHALL INCUDE 1/2 TOTAL AREA OF | | PARAPET WALLS PER SPC SEC.1108.3. | | | | SIZING OF SECONDARY DRAINAGE SYSTEM | | SHALL COMPLY W/SPC SEC.1109.3.SUBMIT | | CALCULATIONS FOR REVIEW. | | | | INDICATE SLOPE OF STORM DRAINAGE PIPING | | ON PLANS.COMPLY W/TABLES 1108.1,1108.2. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-06-29 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
2000-06-29 |
Time |
10:43 |
Rev Time |
0.25 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|