Plan Review Details - Permit 99121043
Plan Review Stops For Permit 99121043
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-04-25 Cont ID  
Sent By dpalmer Date 2000-04-25 Time 07:15 Rev Time 0.00
Received By dpalmer Date 2000-04-25 Time 07:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-01-08 Cont ID  
Sent By dpalmer Date 2000-01-08 Time 11:05 Rev Time 0.00
Received By dpalmer Date 2000-01-08 Time 11:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-12-28 Cont ID  
Sent By jleech Date 1999-12-28 Time 08:00 Rev Time 0.50
Received By jleech Date 1999-12-28 Time 08:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-12-27 Cont ID  
Sent By tlarge Date 1999-12-27 Time 10:19 Rev Time 0.50
Received By tlarge Date 1999-12-27 Time 10:19 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2000-04-21 Cont ID  
Sent By jgomez Date 2000-04-21 Time 19:08 Rev Time 0.50
Received By jgomez Date 2000-04-21 Time 19:08 Sent To  
Notes
2001-01-08 00:00:00SUBMITTAL FOR ITEMS ON PREVIOUS PROVISO
 DATED 1-21-00

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-02-22 Cont ID  
Sent By jgomez Date 2000-02-22 Time 09:11 Rev Time 0.50
Received By jgomez Date 2000-02-22 Time 09:11 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-SPECIFY CONNECTORS CAPABLE OF
 RESISTING THE UPLIFT LOADS CALCULATED
 ON THE ENGINEERED ROOF TRUSSES FOR THE
 FOLLOWING TRUSSES: H6, H7, H8.
 2-REVISE ARCHITECT'S ROOF FRAMING PLAN
 TO MATCH ROOF FRAMING PLAN SHOWN BY
 THE TRUSS COMPANY. AND, SPECIFY THE
 REQUIRED CONNECTORS. SEE COMMENTS ON
 ROOF PLAN BY THE TRUSS COMPANY.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-01-28 Cont ID  
Sent By jgomez Date 2000-01-21 Time 16:17 Rev Time 2.00
Received By jgomez Date 2000-01-21 Time 16:17 Sent To  
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE "A0". PROVIDE ELEVATION
 CERTIFICATE.
 2-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE ASSEMBLY.
 3-STORM PANELS:
 -HIGHLIGHT SPECIFIC MOUNTING CONDITIONS
 AND ANCHOR SPACING TO BE USED
 ACCORDING TO THE EDGE DISTANCE, DESIGN
 PRESSURES, PANEL SPAN AND BUILDING
 CONSTRUCTION.
 NOTE: THIS HOUSE IS BUILT WITH MASONRY
 NOT CONCRETE. THEREFORE, USE ANCHOR
 SPACING AS REQUIRED.
 4-SEE COMMENTS ON PLANS AND UPDATE
 DRAWINGS AS REQUIRED.
 5-RE-SUBMIT PRODUCT APPROVALS FOR DOORS
 AND WINDOWS (AND MULLIONS).

Review Stop Z ZONING
Rev No 1 Status P Date 2000-01-28 Cont ID  
Sent By jgomez Date 2000-01-28 Time 12:33 Rev Time 0.15
Received By jgomez Date 2000-01-28 Time 12:32 Sent To  
Notes
2001-01-08 00:00:00APPROVED BY GRACE 12-23-99