Plan Review Details - Permit 99110632
Plan Review Stops For Permit 99110632 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2000-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2000-02-10 |
Time |
11:56 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2000-02-10 |
Time |
11:56 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NOTES: | | 1-VALUATION OF BUILDINGS WILL BE UPDATED | | FOR APPLICATIONS SUBMITTED AS OF FEB. | | 01 OF YEAR 2000. | | 2-PRODUCT APPROVAL FOR EXTERIOR DOORS | | AND WINDOWS TO BE SUBMITTED SITE | | SPECIFIC AND WITH THE PRODUCT APPROVAL | | FORM SIGNED AND SEALED BY MANUFACTURER | | ENGINEER AND DESIGNER OF RECORD FOR | | THE PLANS. | | OR, PROVIDE STANDARD PRODUCT APPROVAL | | BY SBCCI OR DADE COUNTY. | | 3-PROVIDE SOIL TEST REPORT AS PER CITY | | AMENDMENTS SECTION 1804.2.7. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
1999-12-17 |
|
|
Cont ID |
|
Sent By |
jcaloger |
Date |
1999-12-17 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PLAN A2 WALL SECTION, SPECIFY THE BELOW | | GRADE AND ABOVE GRADE DIMENSION FOR THE | | FOOTER. | | | | PLAN A2, CLARIFY THE METHOD AND TYPE OF | | ROOF TILE TO BE USED. NOTE THE PRODUCT | | APPROVAL SUBMITTED IS FOR THE HIGH | | PROFILE SPANISH S. | | | | DELETE THE EXPIRED MASTER PERMIT NUMBER | | NOTED ON PLANS A2. | | | | PLAN SD2, THE DOOR/WINDOW FASTENING | | SCHEDULE SHOULD BE DELETED AND THESE | | COMPONETS WILL BE REQUIRED TO BE | | INSTALLED AS PER THE SITE SPECIFIC | | ENGINEERING WHICH IS SUBMITTED WITH THE | | PERMIT APPLICATION. | | | | | | THE SIDE ELEVATION WITH A TYPICAL 7'6" | | SIDE SETBACK DOES NOT COMPLY WITH TABLE | | 600. WALL AREA = 388SF X 20%= 77'6". | | WALL OPENINGS= 98'6" | | OPENINGS EXCEED ALLOWED AMT BY 21SF. | | ELEVATION WITH ENCLOSED LANI: | | 476SF X 20%= 95SF | | WALL OPENINGS= 98'6" | | OPENINGS EXCEED ALLOWED AMT BY 3'6". | | | | SEE PLAN REVIEW COMMENTS FROM ELECTRIC | | AND PLUMBING | | | | DELETE LIVINGSTON LANE FROM THE COVER | | PLAN. | | | | PROVIDE TRUSS ENGINEERING FOR REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-02-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-02-05 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-02-05 |
Time |
09:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2000-02-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-12-08 |
Time |
06:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
1999-12-08 |
Time |
06:26 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************UNSAT******************** | | | | 1)NOTE:AS REQ`D BY 1993/1996 NFPA-72 | | 2-2.1.1.1 SMOKE DETECTORS ARE REQ`D | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS | | IN NEW DWELLINGS. | | | | 2)NOTE:AS REQ`D PER 210-52D/215-5 PLEASE | | INCLUDE BATH(S) DEDICATED GFI CIRCUT(S). | | LIST ON PANEL SCHEDULE. | | | | 3)NOTE:PLEASE SHOW AND INCVLUDE AS PART | | OF THE GROUNDING ELECTRODE SYSTEM THE | | GROUND ROD , COLD WATER PIPE AS PER | | 250-81/215-5. | | | | 4)NOTE: NEED TO SUBMIT AIC RATING OF | | EQUIPMENT MAINS TO INCLUDE BRKRS. AS PER | | 110-9/215-5 | | | | 5)NOTE:AS REQ`D BY 210-52E NEED TO HAVE | | RECEPT. ON THE FRONT OF DWELLING. | | | | 6)NOTE: NEED TO SHOW SEPARATE LOAD CAL- | | CULATION FOR EACH UNIT. | | | | NEED TO SUBMIT THE ABOVE INFORMATION | | FOR REVIEW AND APPROVAL.IF THERE ARE ANY | | QUESTIONS PLEASE CALL 659-8096 EXT8372. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
1999-12-08 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
1999-12-08 |
Time |
08:38 |
Rev Time |
1.00 |
Received By |
cthirben |
Date |
1999-11-30 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2000-01-24 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-01-24 |
Time |
11:18 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
2000-01-24 |
Time |
11:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2000-01-24 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-11-18 |
Time |
19:54 |
Rev Time |
0.33 |
Received By |
tlarge |
Date |
1999-11-18 |
Time |
19:54 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | WASHING MACHINE FIXTURE DRAIN SHALL | | CONNECT TO THE STACK.SPC SEC.409.12.2. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2000-02-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2000-02-10 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2000-02-10 |
Time |
11:55 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |