Plan Review Details - Permit 99101261
Plan Review Stops For Permit 99101261
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-07-20 Cont ID  
Sent By dpalmer Date 2000-07-20 Time 14:52 Rev Time 0.00
Received By dpalmer Date 2000-07-20 Time 14:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-05-30 Cont ID  
Sent By dpalmer Date 2000-05-30 Time 15:27 Rev Time 0.00
Received By dpalmer Date 2000-05-30 Time 15:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-11-02 Cont ID  
Sent By dpalmer Date 1999-11-02 Time 06:05 Rev Time 0.00
Received By dpalmer Date 1999-11-02 Time 15:21 Sent To  
Notes
2001-01-08 00:00:00**************PROVISO*******************
  
 1)NOTE:NEED TO SUBMIT AIC RATING OF
 EQUIPMENT AND MAINS ASD PER 110-9/215-5
 AIC RATING IS FIGURED FROM FAULT CURRENT
 CALCULATIONS.
 2)NOTE:PANEL SCHEDULE NEEDS TO SHOW
 CIRCUT(S) FOR BATH AS PER 210-52D.
 3)NOTE:NEED TO SHOW GROUNDING ELECTRODE
 CONDUCTOR GOING TO GROUND ROD AND BLDG.
 STEEL AS PER 250-81
 4)NOTE:ALL OUTLETS SERVING KITCHEN
 COUNTERSPACE ARE TO BE GFI/GFI PROTECTED
 AS PER 210-8-A-6.
 5)NOTE:SMOKE DETECTOR ARE REQ`D INSIDE
 AND OUTSIDE ALL SLEEPING ROOMS AS PER
 1996 NFPA -72 2-2.1.1.1
  
 NEED TO SUBMIT THE ABOVE INFORMATION
 FOR REVIEW AND APPROVAL BEFORE FIRST
 ROUGH ELECTRICAL INSPECTION IS CALLED IN

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-12-20 Cont ID  
Sent By jleech Date 1999-12-20 Time 07:53 Rev Time 0.35
Received By jleech Date 1999-12-20 Time 07:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-10-29 Cont ID  
Sent By jleech Date 1999-10-29 Time 15:25 Rev Time 0.50
Received By jleech Date 1999-10-29 Time 15:25 Sent To  
Notes
2001-01-08 00:00:00PROVISO;
 A/C PLAN TO MATCH FLOOR PLAN BEFORE
 ROUGH A/C INSPECTION.

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-10-28 Cont ID  
Sent By tlarge Date 1999-10-28 Time 07:32 Rev Time 0.33
Received By tlarge Date 1999-10-28 Time 07:31 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-12-20 Cont ID  
Sent By jcaloger Date 1999-12-20 Time 15:33 Rev Time 0.00
Received By jcaloger Date 1999-12-20 Time 15:32 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-10-27 Cont ID  
Sent By gjoyce Date 1999-10-27 Time 08:30 Rev Time 0.50
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***