Plan Review Details - Permit 99101147
Plan Review Stops For Permit 99101147 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2000-04-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-04-11 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-04-11 |
Time |
08:22 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | RISER ONLY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-02-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-02-10 |
Time |
07:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-02-10 |
Time |
07:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
1999-11-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-11-02 |
Time |
06:39 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
1999-11-02 |
Time |
06:39 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *************PROVISO******************* | | | | 1)NOTE:NEED TO SUBMIT AIC RATING OF | | EQUIPMENT AND MAINS.AS PER 110-9/215-5 | | AIC RATING IS FIGURED FROM FAULT CURRENT | | CALCULATIONS. | | 2)NOTE:PLEASE SHOW ON PANEL SCHEDULE | | CIRCUT REQ`D FOR BATHS REQ`D AS PER ART; | | 210-52D | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | FOR REVIEW AND APPROVAL BEFORE FIRST | | ROUGH ELECTRICAL INSPECTION IS CALLED IN |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
1999-11-13 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
1999-11-13 |
Time |
10:12 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
1999-11-13 |
Time |
10:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
1999-10-28 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-10-28 |
Time |
07:02 |
Rev Time |
0.33 |
Received By |
tlarge |
Date |
1999-10-28 |
Time |
07:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
1999-11-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
1999-11-15 |
Time |
16:09 |
Rev Time |
1.50 |
Received By |
jgomez |
Date |
1999-11-15 |
Time |
16:09 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE "A0". PROVIDE ELEVATION | | CERTIFICATE. | | 2-REVISE FOOTING F-6. 16" MINIMUM DEPTH | | SEC 1804.1.3 SBC 1997 AND SEC 1804.1.9 | | CITY AMENDMENTS TO SBC 1997. | | 3-REVISE SIZE OF CEILING FANS. TABLE 6-6 | | FLORIDA ENERGY CODE, 1997 EDITION. | | 4-PROVIDE PRODUCT APPROVAL FOR ENTRY | | DOOR WITH SIDELITE ASSEMBLY AND | | PRODUCT APPROVAL FOR FRENCH DOOR AT | | MASTER SUITE. | | 5-SEE COMMENTS ON PLANS AND REVISE ALL | | ORIGINAL DRAWINGS AS REQUIRED AND | | RESUBMIT TO THIS OFFICE. | | 6-PROVIDE SIGNED, SEALED AND DATED SOIL | | TEST REPORT (ORIGINAL) AND COPIES OF | | THE TESTS PERFORMED. | | 7-STORM PANELS: | | REVISE INSTALLATION SCHEDULE AND KEY | | PLAN TO MATCH ARCHITECT'S PLANS. | | HIGHLIGHT SPECIFIC MOUNTING CONDITIONS | | AND ANCHOR TO BE USED ON THIS PROJECT. | | USE CITY UPDATED INSTALLATION | | SCHEDULE SAMPLE. (ATTACHED). | | 8-REVISE SURVEY. ARCHITECT'S PLANS DON'T | | SHOW EXTENDED PATIO. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
1999-10-27 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
1999-10-27 |
Time |
08:21 |
Rev Time |
0.50 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|