Plan Review Details - Permit 99100480
Plan Review Stops For Permit 99100480 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2000-03-30 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-03-30 |
Time |
08:51 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISIONS FOR A DECK BRIDGE TO PARKING | | DECK 3/30/00 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
1999-12-08 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
1999-11-02 |
Time |
11:42 |
Rev Time |
6.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1. IMPACT FEES MUST BE PAID | | 2. STAIR ON SOUTH EAST CORNER OF GARAGE | | MUST CONTINUE TO THE ROOF DECK | | PARKING LEVEL. | | 3. EXTERIOR WALL ON NORTH, SOUTH AND | | WEST ELEVATION TO BE 2HR RATED WITH | | 1&1/2HR OPREANING PROTECTIVE DEVICES. | | ON NORTH AND SOUTH ELEVATION 2 HR | | PROTECTION REQUIRED WHERE BUILDING JOIN | | AND MUST EXTEND A MINUMIN OF TEN FEET | | PAST THE POINT OF ATTACHMENT. | | 4. CODE COMPLIANCE CERTIFICATION AS PER | | FLORIDA STATUTE 553.79. | | 5. SOIL REPORTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
1999-10-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
1999-10-18 |
Time |
08:35 |
Rev Time |
1.30 |
Received By |
jleahy |
Date |
1999-10-18 |
Time |
08:35 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ***********PROVISO********************* | | E-5 | | 1)NOTE:NEED TO SUBMIT AIC RATING OF | | MAINS,PANELS ETC.FIGURED FROM FAULT | | CURRENT CALCULATIONS.REQ`D AS PER | | 110-9/10 | | 2)NOTE:NEED TO HAVE PLAGUES FOR SERVICE. | | REQ`D AS PER 230-2B. | | | | E-1 | | | | NOTE:ACCESS TO WIREAND SUPPORT OF | | FIXTURE AS PER 410-16 A/B |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
1999-12-08 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
1999-11-01 |
Time |
12:27 |
Rev Time |
3.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SEE NOTES DATED 10-19-99 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
1999-10-18 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
1999-10-18 |
Time |
08:32 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
1999-10-18 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
1999-12-03 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-12-03 |
Time |
10:54 |
Rev Time |
1.50 |
Received By |
tlarge |
Date |
1999-12-03 |
Time |
10:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
1999-10-20 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-10-20 |
Time |
07:35 |
Rev Time |
4.00 |
Received By |
tlarge |
Date |
1999-10-20 |
Time |
06:39 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | | | PIPING PENETRATIONS THROUGH WALLS/FLOORS | | SHALL COMPLY W/STD.BLDG.CODE SEC.705.4.1 | | 705.5, 705.6.(SEE NOTE # 20 ON SHT.P-1.) | | | | WORK SHALL COMPLY W/1994 EDITION OF THE | | STANDARD PLBG.CODE.(SEE NOTE # 1 ON SHT. | | -1.) | | | | SHT.P-1-BRANCH LINES FOR HOSE BIBBS | | SHALL BE VALVED PER SPC SEC.610.4.1, | | 610.4.2. | | | | SHT.P-3-8" STORM DRAIN SHALL BE SLOPED | | PER TABLE 1108.2.(EXCEEDS LIMITS) | | | | WATER PIPING SHALL BE PROTECTED AGAINST | | HAZARD AND NOISE PER SPC SEC.607.8. | | | | SECONDARY DRAINAGE SHALL BE PROVIDED | | FOR ROOF AREA PER SPC SEC.1109.1 AND | | APPENDIX "A". |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
1999-11-03 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
1999-11-01 |
Time |
12:29 |
Rev Time |
0.30 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | DENNIS CAMPBEL 11/3/99 |
|
|
|