Plan Review Details - Permit 99100381
Plan Review Stops For Permit 99100381 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-02-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-02-29 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-02-29 |
Time |
07:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
1999-10-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-10-19 |
Time |
19:28 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
1999-10-19 |
Time |
19:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
1999-10-19 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
1999-10-19 |
Time |
14:46 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
1999-10-19 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
1999-10-16 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
1999-10-16 |
Time |
13:53 |
Rev Time |
0.50 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2000-03-02 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2000-03-02 |
Time |
19:21 |
Rev Time |
1.50 |
Received By |
jgomez |
Date |
2000-03-02 |
Time |
19:21 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | CHECKLIST: | | 1-REVISE CALCULATIONS FOR TABLE 600 AT | | REAR ELEVATION. | | 2-PROVIDE PRODUCT APPROVAL FOR ENTRY | | DOOR WITH SIDELITE ASSEMBLY. | | 3-PROVIDE A COMPLETE INSTALLATION | | SCHEDULE, AS PER CITY SAMPLE SCHEDULE | | ATTACHED, AND A KEY PLAN THAT MATCHES | | ARCHITECTURAL PLANS. | | FILL IN ALL THE INFORMATION REQUIRED | | IN THE INSTALLATION SCHEDULE. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
1999-11-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
1999-11-06 |
Time |
15:34 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
1999-11-06 |
Time |
15:34 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE "A0". PROVIDE ELEVATION | | CERTIFICATE. | | 2-BEDROOM #2 WINDOWS DON'T MEET THE MIN. | | SIZE REQUIREMENTS OF SEC 1005.4.4 OF | | SBC 1997. REVISE ORIGINAL DWG AS REQ'D | | 3-SLIDING GLASS DOORS SPECIFIED ARE | | BIGGER THAN THE ONES IN PRODUCT | | APPROVAL. NEED ANOTHER PRODUCT | | APPROVAL OR SITE SPECIFIC ENGINEERING. | | -STORM PANELS: UPDATE INSTALLATION | | SCHEDULE (AS PER CITY SAMPLE) AND KEY | | PLAN. HIGHLIGHT SPECIFIC MOUNTING | | CONDITIONS AND ANCHORS TO BE USED. | | -PROVIDE PRODUCT APPROVAL FOR ENTRY | | DOOR WITH SIDELITE ASSEMBLY. | | 4-SOIL TEST REPORT TO BE SIGNED AND | | SEALED AND PROVIDE COPIES OF THE | | BORING TESTS. | | 5-REVISE SIZE OF WINDOWS IN MASTER SUITE | | TO MEET TABLE 600 SBC 1997. | | 6-SEE COMMENTS ON PLANS AND REVISE ALL | | ORIGINAL DRAWINGS AS REQUIRED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
1999-10-14 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
1999-10-14 |
Time |
12:41 |
Rev Time |
0.50 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy