Plan Review Stops For Permit 99090252 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2000-09-22 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-09-22 |
Time |
07:27 |
Rev Time |
1.00 |
Received By |
drunnels |
Date |
2000-09-22 |
Time |
07:26 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SHOP DRAWINGS FOR DOME AT MACY'S | | 1. SUBMIT CODE USED FOR DESIGN ON SIGNED | | AND SEALED DRAWINGS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2000-09-21 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-09-21 |
Time |
08:51 |
Rev Time |
2.00 |
Received By |
drunnels |
Date |
2000-09-21 |
Time |
08:51 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVIEW OF A REVISION |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
1999-10-06 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
1999-10-06 |
Time |
11:19 |
Rev Time |
5.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1 REVIEW SEE NOTES ATTACHED TO PLANS | | 1/11/2000 | | 2. SHEET A.1.2 FIRE WALL TO D-BLOCK IF | | WALL IS TO BE USED BY BOTH BUILDINGS | | SUPPLY ENGINEERING MEETING REQUIREMENTS | | OF 1997 STANDARD BUILDING CODE (SBC) | | PAGE 16 DEINITIONS. | | 3. ROOF SYSTEM SEE 1997 SBC SECTIONS | | 1503.1.2.3, SLOPE 1/4" PER FT. | | T-600 1 HOUR FIRE RATING | | 1503.3 PRODUCT APPROVAL FOR 110 MPH | | SYSTEM, COSTAL EXPOSURE. | | 4. PRODUCT APPROVAL ON: | | WINDOWS, DOORS AND SKYLIGHTS FOR 110 MPH | | 5. SHEET A.3.0 AND SITE PLAN VIOLATION | | CHAPTER 32, 1997 SBC SECTION 3204. | | PROVIDE PRODUCT INFORMATION INDICATING | | COMPLIANCE WITH CHAPTER 24, 1997 SBC. | | 6. SOIL TEST REPORT. | | 7. GLAZING PROVIDE PRODUCT APPROVAL | | INFORMATION FOR IMPACT PROTECTION OF ALL | | GLAZED OPEANINGS.DOORS,WINDOWS,SKYLIGHTS | | 8. EXTERIOR TRIM, PROVIDE CODE | | COMPLIANCE INFORMATION FOR TRIM MEETING | | THE REQUIREMENTS OF CHAPTER 26, 1997 SBC | | PROVIDE PRODUCT APPROVAL FOR EFIS SYSTEM | | MEET CHAPTER 26 AND TABLE 600, 1997 SBC |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2000-09-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-09-19 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-09-19 |
Time |
17:26 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | 1)NOTE: PLEASE SHOW ALL AIC RATINGS FOR | | ALL EQUIPMENT BEING SHOWN. ALL MAINS/ | | PANELS/BREAKERS MUST BE RATED FOR | | AVAILABLE FAULT CURRENT. PER 110-9 | | PLEASE SUBMIT ALL THE ABOVE PER 215-5 | | | | 2)NOTE: PLEASE NOTE THAT NOT ALL PANEL | | SCHEDULES WERE SHOWN?? PLEASE DO SO. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-09-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2000-09-13 |
Time |
15:13 |
Rev Time |
1.00 |
Received By |
jleahy |
Date |
2000-09-13 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
1999-09-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
1999-09-30 |
Time |
09:58 |
Rev Time |
2.00 |
Received By |
jleahy |
Date |
1999-09-30 |
Time |
09:40 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | THIS PERMIT IS FOR THE SHELL ONLY NO | | INTERIOR WORK UNTIL A COMPLETE SET OF | | DRAWINGS IS SUBMITTED AND REVIEWED!!! | | | | THIS PLAN IS FOR THE SLAB WORK ONLY NO | | WORK ABOVE THE SLAB WILL NOT BE ALLOWED | | UNTIL PLANS FOR THE INTERIOR WORK ARE | | SUBMITTED!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
1999-10-01 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
1999-10-01 |
Time |
09:35 |
Rev Time |
8.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SEE CHECK LIST ATTACHED TO PLANS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2000-09-09 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-09-09 |
Time |
08:03 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2000-09-09 |
Time |
08:03 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | AS BUILTS DRAWINGS AC1 AND AC2 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2000-01-27 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-01-27 |
Time |
15:36 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2000-01-27 |
Time |
15:36 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SEE ATTACHED LETTER OF EXPLANATION FROM | | THERMALTECH ENGINERING |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2000-01-27 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-01-27 |
Time |
15:34 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2000-01-27 |
Time |
15:34 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ADDENDUM NO. 8 REVISIONS OKAY |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2000-01-27 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-01-27 |
Time |
15:31 |
Rev Time |
1.00 |
Received By |
ndenmark |
Date |
2000-01-27 |
Time |
15:30 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ********CORRECTED BY LETTER ATTACHED**** | | EXHAUST FANS ARE NOT ALL INDICATED ON | | ROOF PROVIDE LOCATION FOR EACH FAN. | | PROVIDE AIR BALANCE SCHEDULE PER 1997 | | SMC 501.2 | | PROVIDE OUTSIDE AIT CALCULATIONS PER | | ASHRAE 62-89 | | EXHAUST AIR TOTALS IN BUILDING DOES NOT | | MATCH FAN CAPACITY ON SCHEDULE |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
1999-10-05 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
1999-10-05 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
ndenmark |
Date |
2000-01-11 |
Time |
17:13 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PROVISO: | | 1) PROTECT OPEN ENDS OF DUCTS THAT ARE | | INSTALLED AT THIS PHASE | | 2)OUTSIDE AIR OPENINGS ARE NOT TO BE | | LOCATED WITHIN 10 FT OF EXHAUST AIR OUT- | | LETS OR PLUMBING VENT STACKS | | 3) APPLIANCES ON ROOF SHALL BE MIN 18" | | ABOVE ROOF SURFACE. THIS DISTANCE IS | | MEASURED TO THE BOTTOM OF THE SUPPORT | | STRUCTURE OF THE STAND, NOT TO THE TOP | | 4) NO OUTSIDE AIR INFORMATION IS PROVIDE | | WITH THIS PLAN. PROVIDE OUTSIDE AIR | | CALCULATIONS PER ASHRAE 62-89 AND AIR | | BALANCE SCHEDULE WITH PLANS FOR INTERIOR | | BUILD-OUT | | THIS INFORMATION BELONGS TO PERMIT | | 99100790 SHELL PERMIT |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
10 |
Status |
P |
Date |
2000-10-03 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-10-03 |
Time |
12:32 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
2000-10-03 |
Time |
12:32 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | AS-BUILTS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
9 |
Status |
F |
Date |
2000-09-26 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-09-26 |
Time |
06:50 |
Rev Time |
2.75 |
Received By |
tlarge |
Date |
2000-09-23 |
Time |
05:38 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1)SUBMIT DETAILED FLOOR PLAN OF TOILET | | ROOM ON FIRST FLOOR.TOILET ROOM SHALL | | COMPLY W/FACBC FOR ALL HANDICAP REQS. | | SHOW LOCATION OF REQD.DRINKING FOUNTAIN. | | FOUNTAIN SHALL COMPLY W/FACBC SEC. | | 4.1.3(10)(A).PROVISIONS SHALL BE MADE | | FOR PEOPLE WHO HAVE TROUBLE BENDING AND | | STOOPING. | | | | 2)SHT.P202-CLARIFY "HWC"IN TOILET ROOM. | | | | 3)SHT.P206-A DRAIN IS REQD.ON THE WATER | | HEATER PAN.TERMINATION OF DRAIN SHALL | | COMPLY W/SPC SEC.507.8.3.DRAIN SHALL BE | | A MIN.OF 1". | | | | 4)SHT.P207-RISER #3-SHOW SQ.FT.AREA | | DRAINED BY EACH CANOPY DRAIN.COMPLY W/ | | SPC SEC.1108.1 AND TABLE 1108.1. | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | QUESTIONS. | | | | TIMOTHY LARGE | | PLUMBING PLANS EXAMINER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
8 |
Status |
F |
Date |
2000-09-15 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-09-15 |
Time |
17:21 |
Rev Time |
2.65 |
Received By |
tlarge |
Date |
2000-09-15 |
Time |
16:55 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1)SUBMIT DETAILED FLOOR PLAN OF TOILET | | ROOM ON 1ST.LEVEL AND LOCATION OF DRINK- | | ING FOUNTAIN.TOILET ROOM SHALL COMPLY W/ | | FACBC FOR ALL HANDICAP REQS.DRINKING | | FOUNTAIN SHALL COMPLY W/FACBC SEC. | | 4.1.3.(10) (A).(PROVISIONS SHALL BE MADE | | FOR PEOPLE WHO HAVE TROUBLE BENDING OR | | STOOPING.) | | | | 2)SHT.P206-HEATER PAN DRAIN CANNOT BE | | INSTALLED AS DRAWN.COMPLY W/COUNTYWIDE | | AMENDMENTS TO SPC SEC.507.8.4.ALSO,SEE | | NOTE ON SHT.P201. | | | | 3)SHT.P208-IF CONDENSATE MATERIAL ON | | ROOF IS PVC IT SHALL BE PAINTED W/A | | WATER BASED PAINT PER MANUF.RECOMMEND- | | ATIONS AND SUPPORTED AT MAX.4' INTERVALS | | NOT 6' AS NOTED.SPC SEC.310.3.6. | | | | CALL IF YOU HAVE ANY QUESTIONS | | TIMOTHY LARGE | | PLUMBING PLANS EXAMINER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
F |
Date |
2000-09-10 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-09-10 |
Time |
07:57 |
Rev Time |
1.00 |
Received By |
tlarge |
Date |
2000-09-10 |
Time |
07:19 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1)SUBMIT PLANS THAT CLEARLY SHOW ALL THE | | REVISIONS.CROSSED OUT AND SCRATCHED OUT | | LINES DO NOT REFLECT THE CHANGES.CLOUD | | ALL AREAS AFFECTED.COUNTYWIDE AMENDMENTS | | TO SPC SEC.104.2.1. | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | ANY QUESTIONS. | | TIMOTHY LARGE | | PLUMBING PLANS EXAMINER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2000-03-14 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-03-14 |
Time |
17:57 |
Rev Time |
0.75 |
Received By |
tlarge |
Date |
2000-03-14 |
Time |
17:57 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ***************PROVISO****************** | | SUBMIT REVISED STORM DRAINAGE RISER FOR | | ADDED ROOF DRAINS.(SEE SHT.A1.3.)SHOW | | SQ.FOOTAGE DRAINED BY EACH DRAIN AND | | CONNECTION TO EXISTING SYSTEM.SIZING | | SHALL COMPLY W/SPC SEC.1108.1,1108.2. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2000-02-24 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-02-24 |
Time |
08:59 |
Rev Time |
1.25 |
Received By |
tlarge |
Date |
2000-02-24 |
Time |
08:59 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | STORM AND PLBG.FIXTURE REQS.REVISIONS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2000-02-04 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-02-04 |
Time |
11:43 |
Rev Time |
2.00 |
Received By |
tlarge |
Date |
2000-02-04 |
Time |
11:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2000-02-09 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-01-25 |
Time |
09:21 |
Rev Time |
4.50 |
Received By |
tlarge |
Date |
2000-01-25 |
Time |
09:21 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REFER TO ALL PREVIOUS PLUMBING COMMENTS. | | ALL CORRECTIONS SHALL BE MADE TO THE | | PLANS PRIOR TO RESUBMITTAL TO THIS DEPT. | | | | *****NOTE:THESE PLANS HAVE BEEN REVIEWED | | THREE TIMES TO DATE AND THERE ARE STILL | | NUMEROUS ITEMS WHICH HAVE NOT BEEN | | PROPERLY ADDRESSED, OR HAVE NOT BEEN | | ADDRESSED AT ALL.I'VE DISCUSSED THESE | | ISSUES W/THE DESIGN PROFESSIONALS FOR | | THIS PROJECT W/LIMITED OR NO SUCCESS AND | | CANNOT WASTE ANY MORE VALUABLE TIME ON | | THIS PROJECT UNTIL ALL ITEMS HAVE BEEN | | CORRECTED.I CAN BE REACHED AT: | | (561)659-8096,EXT.8377. | | | | TIMOTHY K. LARGE | | PLUMBING PLAN REVIEW. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2000-02-09 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-01-06 |
Time |
18:29 |
Rev Time |
5.75 |
Received By |
tlarge |
Date |
2000-01-06 |
Time |
18:29 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SUBMIT TOTAL OCCUPANT LOAD OF STRUCTURE | | PER SPC SEC.407.1.3. | | | | CONFIGURATION OF WOMEN'S RESTROOM ON SHT | | A1.5.DOESN'T CORRELATE W/SHTS.A1.2 OR | | A6.2.CLARIFY. | | | | CLEARLY SHOW LENGTH AND WIDTH DIMENSIONS | | OF HANDICAP STALLS AND TOILET ROOMS. | | COMPLY W/FACBC SEC.4.17.3 EXCEPTION:NEW | | CONSTRUCTION AND FIGURES 28 AND 30. | | | | GRAB BARS BEHIND WATER CLOSETS SHALL | | COMPLY W/FACBC SEC.4.16.4 & 4.17.6. | | | | CLEAR FLOOR SPACE UNDER HANDICAP LAVS. | | SHALL COMPLY W/FACBC SEC.4.19.2. | | | | SHOW MOUNTING HEIGHTS/DIMENSIONS OF ALL | | HANDICAP FIXTURES AND APPURTENANCES. | | COMPLY W/ALL APPLICABLE SECTIONS OF | | FACBC. | | | | DRINKING FOUNTAIN BY SECURITY OFFICE | | SHALL COMPLY W/FACBC SEC.4.1.3(10)(A) | | | | SUBMIT ISOMETRIC DRAWING FOR COMPLETE | | UNDERGROUND STORM DRAINAGE PIPING FOR | | THE BUILDING STORM DRAINAGE SYSTEM PER | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 | | SIZING OF SYSTEM SHALL COMPLY W/SPC SEC. | | 1108.2.1.SYSTEM DOESN'T COMPLY. | | | | SUBMIT CALCULATIONS/DETAILS FOR | | PROVISIONS FOR SECONDARY DRAINAGE FOR | | ROOF STRUCTURE PER SPC SEC.1109.SUBMIT | | DETAILS OF SCUPPERS W/ALL DIMENSIONS. | | | | CLEARLY SHOW TERMINATION POINT OF STORM | | DRAINAGE SYSTEM.(SEE 8"RISERS AND CANOPY | | AT ROTUNDA ON A200.) | | | | SHT.P200-RISER #4 -4"ROOF DRAIN NOT | | SHOWN ON SHT.P206. | | | | SHT.P201-RISER FOR MSB ON 2ND FLR.DOES | | NOT CORRELATE W/ISOMETRIC ON P206.(SEE | | AREA AT COLS.9-10 BETWEEN E-F.) | | | | FLOOR DRAINS IN RESTROOMS AND FAMILY | | TOILET ROOM ARE S-TRAPPED.COMPLY W/SPC | | SEC.901.2. | | | | SHOW SIZE OF CONDENSATE DRAINS ON PLANS. | | COMPLY W/SMC SEC.304.8.4. | | | | SHT.P206.-2ND.FLR.MEN'S AND WOMEN'S R.R. | | SIZING OF DRAINAGE SYSTEM SHALL COMPLY | | W/SPC TABLE 714.2.(REFER TO 1 1/2"& 2" | | DRAINS). | | | | BRANCH VENT SIZING FOR WATER CLOSETS | | SHALL COMPLY W/SPC TABLE 902.2. | | | | SHT.P206-JANITOR SINK NOT SHOWN ON WATER | | AND SANITARY RISERS. | | | | SHT.P201 REFERS TO SHT.P700 FOR CONTIN- | | UATION OF SANITARY.NO SUCH SHEET IS IN | | PLANS. | | | | A HEATER PAN AND PAN DRAIN ARE REQUIRED | | FOR THE EWH.COMPLY W/COUNTYWIDE AMEND- | | MENTS TO SPC SEC.507.8.1. | | | | MAX.TEMPERATURE OF WATER TO PUBLIC REST- | | ROOMS SHALL BE 110 DEGREES PER FEC SEC. | | 412.1.ABCD.2.3.2. | | | | HOSE BIBBS SHALL BE VALVED PER SPC SEC. | | 610.4.1. | | | | SHT.P206-WATER SUPPLY CONTROL SHALL | | COMPLY W/SPC SEC.610.4.1 & 610.4.2. | | | | VENTS THRU ROOF SHALL NOT BE INCREASED | | IN SIZE (ONLY WHERE FROST CLOSURE IS A | | PROBLEM.)SPC SEC.905.2,918,920.2.-SEE | | FUTURE RESTROOM AREA,& F.D.AT PUMP ROOM. | | | | THE FOLLOWING JOB SPECS.DO NOT COMPLY | | W/SPC.THEY SHALL BE CHANGED TO COMPLY | | W/THE FOLLOWING CODE SECS.: | | PAGE 15410-15-(H)(I)-VERT.AND HORIZONTAL | | SUPPORTS SHALL COMPLY W/SPC SEC.310.2- | | 310.3.6. | | PAGE 15430-6-(3.3)-CLEANOUTS SHALL | | COMPLY W/SPC 710.2.4. | | PAGE 15497(1-3)SECS.3.2-3.5-SYSTEM TESTS | | SHALL COMPLY W/SPC SECS.311.2-311.7.5. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2000-02-09 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-09-21 |
Time |
16:56 |
Rev Time |
6.25 |
Received By |
tlarge |
Date |
1999-09-18 |
Time |
12:00 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SUBMIT OCCUPANT LOAD PER SPC SEC.407.1.3 | | | | NUMBER OF DRINKING FOUNTAINS FOR | | OCCUPANT LOAD SHALL COMPLY W/TABLE 407 | | OF SPC. | | | | SUBMIT STORM DRAINAGE ISOMETRIC FOR | | REVIEW.COMPLY W/SPC SECS.1108. | | | | SUBMIT CALCULATIONS/DETAILS FOR | | PROVISIONS FOR SECONDARY DRAINAGE FOR | | ROOF STRUCTURE PER SPC SEC.1109. | | | | CONFIGURATION OF WOMEN'S RESTROOM ON | | A1.2 DOESN'T CORRELATE W/SHT.A1.5 OR | | A6.2.(AMOUNT OF PLBG.FIXTURES DOESN'T | | MATCH.) | | | | CLEARLY SHOW LENGTH AND WIDTH DIMENSIONS | | OF HANDICAP STALLS AND TOILET ROOM. | | COMPLY W/FACBC SEC.4.17.3 EXCEPTION:NEW | | CONSTRUCTION AND FIGURES 28 & 30. | | | | SHT.A6.2-GRAB BARS BEHIND WATER CLOSETS | | SHALL COMPLY W/FACBC SEC.4.16.4 & 4.17.6 | | | | CLEAR FLOOR SPACE UNDER HANDICAP LAV. | | SHALL COMPLY W/FACBC SEC.4.19.2. | | | | SHOW MOUNTING HEIGHTS/DIMENSIONS OF ALL | | HANDICAP FIXTURES AND APPURTENANCES. | | COMPLY W/FACBC. | | | | DISTANCE OF FLOOR DRAINS FROM VENT SHALL | | COMPLY W/TABLE 908.1 OF COUNTYWIDE | | AMENDMENTS TO STD.PLBG.CODE. | | | | SHT.P200-CLEARLY SHOW CONTINUATION POINT | | OF 8" STORM DRAIN AND SANITARY LINE.SEE | | COLS.#B-D & "10". | | | | SUBMIT A STORM DRAINAGE ISOMETRIC FOR | | REVIEW.NOTE SQUARE FOOTAGE DRAINED BY | | EACH ROOF DRAIN.COMPLY W/SPC SEC.1108.1, | | 1108.2. | | | | SHT.P201-RISER FOR MSB ON 2ND FLR. | | DOESN'T CORRELATE W/ISOMETRIC ON P206. | | SPC 104.2.1. | | | | FLOOR DRAINS ARE NOT PROPERLY VENTED PER | | SPC SEC.901.2 | | | | FLOOR DRAIN IS REQD.IN THE FAMILY TOILET | | ROOM PER SPC SEC.409.4.1.1. | | | | SHT.P206-CLEARLY SHOW ORIGINATION POINT | | OF DOMESTIC WATER LINE.SPC 104.2.1. | | A BACKFLOW DEVICE IS REQD.ON THE WATER | | SERVICE TO THE BLDG.PER SPC SEC.606. | | | | JOB SPECS.-PG.15410-15.-(H)(I)-VERTICAL | | AND HORIZ.SUPPORTS SHALL COMPLY W/SPC | | SEC.310.2-310.3.6. | | | | JOB SPECS.-PG.15430-6.-(3.3)-CLEANOUTS | | SHALL COMPLY W/SPC 710.2.4. | | | | JOB SPECS.-PG.15497-SECS.3.2-3.5.SYSTEM | | TESTS SHALL COMPLY W/SPC SECS.311.2 - | | 311.7.5. | | | | *************SHELL ONLY***************** | | | | SUBMIT ISOMETRIC DRAWINGS FOR ALL WATER, | | SANITARY,STORM AND CONDENSATE SYSTEMS TO | | BE INSTALLED IN THE SHELL STRUCTURE. . | | SPC 104.2.1. | | | | ROOF SYSTEM SHALL BE SUPPLIED W/ | | PROVISIONS FOR SECONDARY DRAINAGE PER | | SPC SEC.1109. | | | | CLEARLY SHOW ORIGINATION /TERMINATION | | POINTS OF THE SANITARY,STORM,CONDENSATE, | | AND WATER SYSTEMS ON THE PLANS.SPC 104.2 | | | | A BACKFLOW PREVENTION DEVICE IS REQD.ON | | THE DOMESTIC WATER SYSTEM PER SPC SEC. | | 606. | | | | NOTE:PLUMBING PROVISO: | | THE ABOVE INFORMATION FOR THE SHELL BLDG | | SHALL BE SUBMITTED FOR REVIEW WITHIN | | 30 DAYS OF ISSUANCE OF SHELL PERMIT. | | 10/4/99.T.LARGE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
1999-09-10 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
1999-09-09 |
Time |
14:45 |
Rev Time |
0.75 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NEEDS SITE PLAN, PASSED TO BUILDING | | CALLED JIM 9-9-99 |
|
|