Plan Review Stops For Permit 99081314 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
1999-12-01 |
Time |
09:20 |
Rev Time |
2.00 |
Received By |
fknapp |
Date |
1999-12-01 |
Time |
05:58 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ****************PROVISO***************** | | | | SBC 104.2.2 | | | | 1)PROVIDE STORM PANEL INSTALLATION | | SCHEDULE AND KEY PLAN WITH SPECIFIC | | MOUNTING AND ANCHORS TO BE USED UNDER | | SEPERATE PERMIT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
1999-11-18 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
1999-11-18 |
Time |
08:30 |
Rev Time |
2.00 |
Received By |
fknapp |
Date |
1999-11-18 |
Time |
08:30 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************PROVISO******************* | | | | SBC 104.2.2 | | | | 1)PROVIDE 2 CURRENT COPIES OF PRODUCT | | APPROVALS FOR DOUBLE OUTSWING DOORS. | | | | 2)PROVIDE STORM PANEL INSTALLATION | | SCHEDULE AND KEY PLAN WITH SPECIFIC | | MOUNTING AND ANCHORS TO BE USED. | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH CO., THE PERMIT PLANS STAMPED BY | | THEM AND THE PINK RECIEPT ATTACHED TO | | THE PERMIT APPLICATION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
1999-10-05 |
Time |
15:41 |
Rev Time |
5.00 |
Received By |
fknapp |
Date |
1999-10-05 |
Time |
09:05 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | DENIED SEE CHECKLIST |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
1999-11-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
1999-11-18 |
Time |
15:00 |
Rev Time |
0.45 |
Received By |
dpalmer |
Date |
1999-11-18 |
Time |
14:59 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1- NEED TO KNOW HOW PANELS ARE FED | | | | 2- HOW MANY CKTS TO CABANA | | | | 3- WHERE ARE THE MAINS? |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-11-03 |
Time |
06:46 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
1999-11-03 |
Time |
06:46 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ************DENIED********************** | | | | 1)NOTE:SERVICE ENTRANCE CONDUCTORS NEED | | TO BE SIZED FOR ATLEAST THE LOAD OF THE | | SERVICE!!!!!! | | 2)NOTE:PLEASE REVISE LOAD CALCULATION | | COMBINING BOTH PANELS FOR SERVICE | | CALCULATION. | | 3)NOTE:RISER ONLY SHOWS 4/0 WHICH IS | | RATED FOR 230 AMPS AND CAN BE PROTECTED | | AT 250A BUT THE LOAD EXCEEDS THAT RATING | | OF THE WIRE.AS PER 310-16!!!!! | | SIZE SERVICE ENTRANCE CONDUCTORS ACCORD. | | 4)NOTE:PLANS SHOW 2 WATER HEATERS AND | | 2 DRYERS???? PANEL SCHEDULES AND LOAD | | CALCULATIONS ONLY SHOW ONE OF EACH | | BEING FIGURED???? PLEASE VERIFY!!! | | 5)NOTE: PLEASE ADD CIRCUT(S) ON PANEL | | SCHD.THAT ARE REQ`D BY 210-52D FOR BATHS | | 6)NOTE:NEED TO HAVE GROUNDING ELECTRODE | | CONDUCTOR GOING TO STEEL OF NEW | | STRUCTURES.AS PER 250-81 | | 7)NOTE:AT DETACHED STRUCTURE BACK YARD,, | | IF FED BY MORE THAN ONE BRANCH CIRCUT | | THEN MUST MEET CODE AS TO PROPER GROUND- | | -ING. AS PER 250-24 C-3 | | 8)NOTE:ON PLANS,,,SHEET 5 OF 15 SHOW | | 4 A/C COND. UNITS AND 9 OF 15 SHOW ONLY | | 2 A/C COND. UNITS??? ALSO PLANS 3 AHU`S | | ??WHAT ARE THE CORRECT AMOUNT OF UNITS?? | | 9)NOTE:AS REQ`D BY ART;210-8-A-6 ALL | | OUTLETS SERVING KITCHEN COUNTERSPACE ARE | | TO BE GFI/GFI PROTECTED. PLEASE LABEL. | | 10)NOTE:PLEASE NOTE SOME MISSING OUTLETS | | THAT ARE REQ`D BY 210-52 | | 11)NOTE:NEED TO SUBMIT THE AIC RATING OF | | EQUIPMENT MAINS AND BRKRS.AIC RATING IS | | IGURED FROM FAULT CURRENT CALCULATIONS. | | AS REQ`D BY 110-9/10 AND 215-5 | | NOTE ALL THE ABOVE SERVICE INFORMATION | | REQ`D BY 215-5 | | | | PLEASE SUBMIT ALL THE ABOVE INFORNATION | | REQ`STED FOR REVIEW AND APPROVAL!! | | ELEC WILL NOT PRINT |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-10-05 |
Time |
07:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
1999-10-05 |
Time |
07:13 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ****************DENIED****************** | | | | 1)NOTE:AS PER ART210-8-A-6 ALL RECEPTS. | | SERVING KITCHEN COUNTER SPACE ARE TO BE | | GFI/GFI PROTECTED, TO INCLUDE KITCHEN | | AREA. | | 2)NOTE;IF DETACHED CABANA HAS NORE THAN | | ONE CIRCUT TO THAT STUCTURE,THEN IT REQ` | | S A MEANS OF DISC. ST THAT STRUCTURE. | | 3)AS PER 310-16 SERVICE ENTRANCE CONDS. | | ARE NOT OF SUFFICENT SIZE.LOAD CALCS. | | SHOW LOAD ON PANEL'A' AT 186.22 AND LOAD | | ON PANEL'B'AT 80.54 THATS 266.76 ON 4/0 | | WIRE WHICH IS ONLY RATED FOR 230AMPS!!! | | SIZE CONDUCTORS AS PER 310-16 TO GUTTER | | TAPS MAY BE SIZED TO PANEL RATING. | | 4)NOTE:AS PER ARTS;110-9/215-5 NEED TO | | SUBMIT AIC RATING OF ALL EQUIPMENT | | BEING USED TO INCLUDE AIC RATING OF | | MAINS, | | 5)NOTE;SIZE GUTTER TO NEW SERVICE | | CONDUCTORS | | 6)NOTE;SIZE GROUNDING ELECTRODE COND- | | -UCTOR TO NEW SERVICE ENTRANCE CONDUCTOR | | 7)NOTE;AS PER ART 250-81,GROUNDING ELEC- | | -TRODE CONDUCTOR TO GOT TO TO BLDG. | | STEEL OF NEW ADDITIONS. | | | | NEED TO SUBMIT THE ABOVE INFORMATION | | FOR APPROVAL. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
1999-12-01 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | JHL:PROVISO 11/13/99 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
1999-10-04 |
Time |
15:27 |
Rev Time |
0.35 |
Received By |
jwitmer |
Date |
1999-10-04 |
Time |
15:27 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NO A/C PLANS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
1999-11-30 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-11-30 |
Time |
12:58 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
1999-11-30 |
Time |
12:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
N |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-11-23 |
Time |
15:29 |
Rev Time |
0.33 |
Received By |
jwitmer |
Date |
1999-11-23 |
Time |
15:28 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PLUMBING RISER SHALL MATCH FLOOR PLAN AS | | TO LOCATION OF FIXTURES.COUNTYWIDE | | AMENDMENTS TO STD.PLBG.CODE SEC.104.2.2 | | | | FIXTURES DOWNSTREAM OF WATER CLOSETS | | SHALL BE VENTED PER SPC SEC.913.2. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-11-05 |
Time |
09:45 |
Rev Time |
0.65 |
Received By |
jwitmer |
Date |
1999-11-05 |
Time |
09:45 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PLUMBING RISER SHALL MATCH THE FLOOR | | PLAN AS TO LOCATION OF FIXTURES. | | | | FIXTURES DOWNSTREAM OF WATER CLOSETS | | SHALL BE VENTED.SPC 913.2 | | | | SIZE ALL SECTIONS OF THE PLUMBING RISER. | | | | TUB AND SHOWER ON 2ND FLR.NOT PROPERLY | | VENTED.SPC 901.2. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-09-22 |
Time |
07:50 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
1999-09-22 |
Time |
07:50 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SUBMIT SANITARY ISOMETRICS FOR PLBG.WORK | | TO BE DONE IN EACH STRUCTURE.SPC SEC. | | 104.2.1. | | | | FIXTURES LOCATED DOWNSTREAM OF WATER | | CLOSETS SHALL BE VENTED PER SPC SEC. | | 913.2 | | | | WASHING MACHINE NOT PERMITTED ON 2"CROSS | | PER SPC SEC.409.12.3. | | | | VEGGIE SINK,BAR SINK,AND 2ND FLR.LAV.ARE | | SHOWN ON THE FLOOR PLAN BUT NOT ON THE | | SANITARY ISOMETRIC.SPC 104.2.1. | | | | SHOW FIXTURE CLEARANCES OF WATER CLOSETS | | COMPLY W/SPC SEC.403.4. | | | | WATER CLOSET AND SHOWER ARE NOT PROPERLY | | VENTED.COMPLY W/SPC SEC.901.2.(SEE TUB | | AND SHOWER ON 2ND.FLR.ALSO.) | | | | SANITARY ISOMETRIC SHALL CORRELATE W/ | | THE FLOOR PLAN.SPC 104.2.1. | | | | DIMENSIONS REQD.FOR GARAGE SHOWER.COMPLY | | W/COUNTYWIDE AMENDMENTS SEC.409.8.2.1. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-08-30 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
1999-12-01 |
Time |
13:37 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SUBMIT SANITARY ISOMETRIC FOR ALL NEW | | PLUMBING BEING INSTALLED.SPC 104.2.1. | | | | SEPARATE PERMITS ARE REQUIRED FOR EACH | | STRUCTURE.104.1.1. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
1999-12-01 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
1999-10-02 |
Time |
09:15 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PLUMBING PLAN REVIEW UNSAT | | (1) SHT 3 LABEL VEG. & BAR SINK ON PLAN | | DRAWING,ISOMETRIC DOES NOT MATCH. | | (2) WATER CLOSES NOT WET VENTED, | | MAJOR OVER A MINOR. (* TYPICAL) | | (3) VENT TUB & SHOWER. | | (4) GARAGE APT. KITCHEN SINK NOT SHOWN | | ON ISOMETRIC. | | (5) SIZE & LOCATION OF ALL WATER HEATERS | | STD PLBG. CODE 94 SEC 104.2.1 | | SEE SHT A-3 END OF COMMENTS |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
1999-11-17 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
1999-11-17 |
Time |
15:24 |
Rev Time |
0.25 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
1999-08-31 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
1999-08-31 |
Time |
08:48 |
Rev Time |
0.25 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | CONS SIGNED PERMIT OUT |
|
|