Plan Review Details - Permit 99081098
Plan Review Stops For Permit 99081098
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2000-04-13 Cont ID  
Sent By lmartine Date 2000-04-13 Time 06:59 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2000-03-28 Cont ID  
Sent By lmartine Date 2000-03-28 Time 09:33 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00OFFICE NOT ACCESSIBLE,REVISION DENIED
 3/28/00 LM

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-09-21 Cont ID  
Sent By lmartine Date 1999-09-21 Time 17:17 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-09-21 Cont ID  
Sent By lmartine Date 1999-09-21 Time 17:17 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-09-21 Cont ID  
Sent By lmartine Date 1999-09-21 Time 17:20 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-12-21 Cont ID  
Sent By tlarge Date 1999-12-21 Time 14:35 Rev Time 0.65
Received By tlarge Date 1999-12-21 Time 14:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 1999-12-21 Cont ID  
Sent By tlarge Date 1999-12-20 Time 07:07 Rev Time 0.65
Received By tlarge Date 1999-12-20 Time 07:07 Sent To  
Notes
2001-01-08 00:00:00SUBMIT A WATER RISER DIAGRAM FOR REVIEW.
 WATER SUPPLY CONTROL SHALL COMPLY W/SPC
 SEC.610.4.1,610.4.2.
  
 SUBMIT A REVISED SANITARY RISER DIAGRAM
 THAT CLEARLY REFLECTS THE SCOPE OF WORK
 BEING DONE.(SHOW FLOOR DRAINS AND
 CLARIFY IF UTILITY SINK WILL BE
 INSTALLED OR DELETED.)

Review Stop P PLUMBING
Rev No 1 Status N Date 1999-12-21 Cont ID  
Sent By tlarge Date 1999-09-09 Time 12:44 Rev Time 1.50
Received By tlarge Date 1999-09-09 Time 12:44 Sent To  
Notes
2001-01-08 00:00:00PLANS SHALL BE SIGNED AND SEALED BY A
 ESIGN PROFESSIONAL PER SPC SEC.104.2.3.
  
 SUBMIT A WATER RISER DIGRAM FOR REVIEW.
 WATER SUPPLY CONTROL SHALL COMPLY W/SPC
 SEC.610.4.1.,610.4.2.
  
 FLOOR DRAINS ARE REQ'D. IN THE TOILET
 ROOMS PER SPC SEC.409.4.1.1.
  
 FLOORS AND WALLS SHALL BE NONABSORBENT
 MATERIAL TO A HEIGHT OF 4' PER SBC
 1204.2.
  
 TOILET ROOMS SHALL COMPLY W/FACBC IN
 ALL RESPECTS FOR HANDICAP ACCESSIBILITY.
 SUBMIT ELEVATION DETAILS FOR ALL HANDI-
 CAP FIXTURES.
  
 PIPES EMBEDDED IN CONCRETE SHALL COMPLY
 W/SBC SEC.1907.3.5,1907.3.6.

Review Stop Z ZONING
Rev No 1 Status P Date 1999-08-25 Cont ID  
Sent By gjoyce Date 1999-08-25 Time 09:36 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***