Plan Review Details - Permit 99080266
Plan Review Stops For Permit 99080266
Review Stop E ELECTRICAL
Rev No 5 Status P Date 2000-06-29 Cont ID  
Sent By dpalmer Date 2000-06-29 Time 15:33 Rev Time 0.00
Received By dpalmer Date 2000-06-29 Time 15:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2000-06-16 Cont ID  
Sent By dpalmer Date 2000-06-16 Time 12:42 Rev Time 0.00
Received By dpalmer Date 2000-06-16 Time 12:42 Sent To  
Notes
2001-01-08 00:00:00PLANS RELINED FOR SD`S AND BATH GFI`S

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-04-11 Cont ID  
Sent By dpalmer Date 2000-04-11 Time 15:31 Rev Time 0.00
Received By dpalmer Date 2000-04-11 Time 15:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-02-18 Cont ID  
Sent By dpalmer Date 2000-02-18 Time 16:09 Rev Time 0.00
Received By dpalmer Date 2000-02-18 Time 16:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-09-03 Cont ID  
Sent By dpalmer Date 1999-09-03 Time 15:44 Rev Time 0.00
Received By dpalmer Date 1999-09-03 Time 15:44 Sent To  
Notes
2001-01-08 00:00:00**************PROVISO*******************
  
 1) NOTE:AS PER 1996 NFPA-72 2-2.1.1.1
 REQ`S FOR NEW CONSTRUCTION SMOKE
 DETECTORS INSIDE AND OUTSIDE ALL
 BEDROOMS.
 2) NOTE:AS PER 210-8-A-6 ALL RECEPTS.
 SERVING KITCHEN COUNTERSPACE ARE TO BE
 GFI/ GFI PROTECTED.
 3) NOTE:GOUNDING ELECTRODE CONDUCTOR
 TO GO TO BLDG.STEEL ALSO AS PER ART;
 250-81
 4) NOTE:NEED TO SUBMIT AIC RATING OF
 ALL EQUIPMENT AND RATING OF BREAKERS,
 AS PER 110-9 AND 215-5
  
 ALL THE ABOVE NEEDS TO BE SUBMITTED AND
 APPROVED BEFORE ELECTRICAL ROUGH
 INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-06-17 Cont ID  
Sent By cthirben Date 2000-06-17 Time 07:56 Rev Time 1.00
Received By cthirben Date 2000-06-17 Time 07:55 Sent To  
Notes
2001-01-08 00:00:00NOTES
 RE-STAMP ONLY.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-08-17 Cont ID  
Sent By jleech Date 1999-08-17 Time 12:12 Rev Time 0.50
Received By jleech Date 1999-08-17 Time 12:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-06-17 Cont ID  
Sent By tlarge Date 2000-06-17 Time 06:47 Rev Time 0.30
Received By tlarge Date 2000-06-17 Time 06:47 Sent To  
Notes
2001-01-08 00:00:00DUPLICATE PLAN.

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-08-20 Cont ID  
Sent By tlarge Date 1999-08-20 Time 18:20 Rev Time 0.50
Received By tlarge Date 1999-08-20 Time 18:20 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-09-17 Cont ID  
Sent By jcaloger Date 1999-09-17 Time 10:07 Rev Time 0.00
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-08-06 Cont ID  
Sent By gjoyce Date 1999-08-06 Time 09:24 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved