Plan Review Details - Permit 99080265
Plan Review Stops For Permit 99080265 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2000-02-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-02-28 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-02-28 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-02-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-02-26 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-02-26 |
Time |
12:14 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PLEASE NOTE THAT YOU ARE SHOWING FOUR | | SMOKE DETECTORS OUTSIDE IN THE HALLWAY?? | | THIS IS MORE THAN REQUIRED. THEY MAY BE | | INSTALLED HOWEVER. THIS IS JUST A NOTE | | IF ALL ARE SHOWN ON PLANS THEN ALL MUST | | BE INSTALLED. | | | | ALSO PLEASE NOTE THAT THE PLANS STILL | | SHOW A DISCONNECT NEXT TO THE WATER | | HEATER? MUST BE INSTALLED IF PLANS SHOW. | | | | PLEASE SUBMIT ANY CHANGES TO PLANS | | PRIOR TO ANY INSPECTIONS. | | IF THERE ARE ANY QUESTIONS PLEASE CALL | | 659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
1999-09-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-09-07 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
1999-09-07 |
Time |
16:30 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ***************PROVISO****************** | | | | 1)NOTE:AS PER 1996 NFPA-72 2-2.1.1.1 | | SMOKE DETECTORS ARE REQD INSIDE AND | | OUTSIDE BEDROOMS. | | 2)NOTE:GOUNDING ELECTRODE CONDUCTOR | | IS REQ`D TO GO TO GRND.ROD AND BLDG. | | STEEL ALSO AS PER 250-81 | | 3)NOTE:AS PER 210-8-A-6 ALL RECEPTS, | | SERVING KITCHEN COUNTER SPACE ARE TO BE | | GFI/GFI PROTECTED. | | 4)NOTE:PLEASE DRAW IN LOCATION OF SECOND | | A/C COND. UNIT, DISC, AND WP GFI AS REQ` | | D BY 210-63. | | PLEASE SUBMIT THE AIC RATING OF ALL | | EQUIPMENT AND BREAKERS BEING USED, FIG- | | IURED FROM FAULT CURRNET CACULATIONS. | | AS PER 110-9 AND 215. | | | | PLEASE SUBMIT AND HAVE APPROVED FOR | | APPROVAL BEFORE FIRST ELECTRICAL ROUGH | | INSPECTION, |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
1999-08-17 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
1999-08-17 |
Time |
15:44 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
1999-08-17 |
Time |
15:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
1999-08-20 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-08-20 |
Time |
18:21 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
1999-08-20 |
Time |
18:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
1999-09-20 |
|
|
Cont ID |
|
Sent By |
jcaloger |
Date |
1999-09-20 |
Time |
16:03 |
Rev Time |
2.50 |
Received By |
jcaloger |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
1999-08-09 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
1999-08-09 |
Time |
08:37 |
Rev Time |
0.50 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|