Plan Review Details - Permit 99080265
Plan Review Stops For Permit 99080265
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-02-28 Cont ID  
Sent By dpalmer Date 2000-02-28 Time 15:32 Rev Time 0.00
Received By dpalmer Date 2000-02-28 Time 15:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-02-26 Cont ID  
Sent By dpalmer Date 2000-02-26 Time 12:14 Rev Time 0.00
Received By dpalmer Date 2000-02-26 Time 12:14 Sent To  
Notes
2001-01-08 00:00:00PLEASE NOTE THAT YOU ARE SHOWING FOUR
 SMOKE DETECTORS OUTSIDE IN THE HALLWAY??
 THIS IS MORE THAN REQUIRED. THEY MAY BE
 INSTALLED HOWEVER. THIS IS JUST A NOTE
 IF ALL ARE SHOWN ON PLANS THEN ALL MUST
 BE INSTALLED.
  
 ALSO PLEASE NOTE THAT THE PLANS STILL
 SHOW A DISCONNECT NEXT TO THE WATER
 HEATER? MUST BE INSTALLED IF PLANS SHOW.
  
 PLEASE SUBMIT ANY CHANGES TO PLANS
 PRIOR TO ANY INSPECTIONS.
 IF THERE ARE ANY QUESTIONS PLEASE CALL
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-09-07 Cont ID  
Sent By dpalmer Date 1999-09-07 Time 16:30 Rev Time 0.00
Received By dpalmer Date 1999-09-07 Time 16:30 Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
  
 1)NOTE:AS PER 1996 NFPA-72 2-2.1.1.1
 SMOKE DETECTORS ARE REQD INSIDE AND
 OUTSIDE BEDROOMS.
 2)NOTE:GOUNDING ELECTRODE CONDUCTOR
 IS REQ`D TO GO TO GRND.ROD AND BLDG.
 STEEL ALSO AS PER 250-81
 3)NOTE:AS PER 210-8-A-6 ALL RECEPTS,
 SERVING KITCHEN COUNTER SPACE ARE TO BE
 GFI/GFI PROTECTED.
 4)NOTE:PLEASE DRAW IN LOCATION OF SECOND
 A/C COND. UNIT, DISC, AND WP GFI AS REQ`
 D BY 210-63.
 PLEASE SUBMIT THE AIC RATING OF ALL
 EQUIPMENT AND BREAKERS BEING USED, FIG-
 IURED FROM FAULT CURRNET CACULATIONS.
 AS PER 110-9 AND 215.
  
 PLEASE SUBMIT AND HAVE APPROVED FOR
 APPROVAL BEFORE FIRST ELECTRICAL ROUGH
 INSPECTION,

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-08-17 Cont ID  
Sent By jleech Date 1999-08-17 Time 15:44 Rev Time 0.50
Received By jleech Date 1999-08-17 Time 15:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-08-20 Cont ID  
Sent By tlarge Date 1999-08-20 Time 18:21 Rev Time 0.50
Received By tlarge Date 1999-08-20 Time 18:21 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-09-20 Cont ID  
Sent By jcaloger Date 1999-09-20 Time 16:03 Rev Time 2.50
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-08-09 Cont ID  
Sent By gjoyce Date 1999-08-09 Time 08:37 Rev Time 0.50
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***