Plan Review Stops For Permit 99071834 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2000-02-04 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2000-02-02 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
1999-08-30 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
1999-08-30 |
Time |
13:29 |
Rev Time |
99.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
1999-12-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-12-16 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SAME AS ORIGINAL NOTES, BEFORE ROUGH!!!! |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
1999-11-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-11-29 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SAME AS FIRST NOTES. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
1999-08-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
1999-08-17 |
Time |
07:45 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
1999-08-17 |
Time |
07:45 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************PROVISO****************** | | | | PLEASE SUBMIT AIC RATING OF EQUIPMENT | | BEING USED, FIGURED FROM FAULT CURRENT | | CALCULATIONS. | | | | ABOVE NEDDS TO BE SUBMITTED AND APPROVED | | BEFORE ROUGH ELECTRICAL INSPECTION. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
1999-10-14 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
1999-08-30 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED PER RHETT TURNQUIST |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2000-01-28 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-01-28 |
Time |
14:31 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2000-01-28 |
Time |
14:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
1999-12-16 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
1999-12-16 |
Time |
14:06 |
Rev Time |
0.25 |
Received By |
ndenmark |
Date |
1999-12-16 |
Time |
14:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
1999-08-30 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
1999-08-30 |
Time |
09:41 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
1999-08-30 |
Time |
09:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2000-02-02 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-02-02 |
Time |
07:19 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
2000-02-02 |
Time |
07:19 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISE GAS DWG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
1999-12-17 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
1999-12-17 |
Time |
14:18 |
Rev Time |
0.75 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REWISION SEE SHT A-6 PROVISO ON GAS | | VALVES,PIPE SIZING. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
1999-11-29 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-11-29 |
Time |
07:44 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
1999-11-29 |
Time |
07:44 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SIZING OF GAS LINES TO APPLIANCES SHALL | | COMPLY W/S.G.C. TABLE 305.4A. | | | | SUBMIT CORRECT BTU LOAD FOR FRYERS AND | | CORRECT TOTAL BTU LOAD FOR SYSTEM.(PLANS | | SHOW FRYERS AS 45,000 AND 90,000 BTU'S. | | | | LOCATION OF S.O.V. AND UNION ON GAS LINE | | SHALL COMPLY W/NFPA 54 SEC.5.5.4. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
1999-10-13 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-10-13 |
Time |
13:10 |
Rev Time |
0.75 |
Received By |
tlarge |
Date |
1999-10-13 |
Time |
13:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
1999-10-14 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-08-14 |
Time |
08:58 |
Rev Time |
1.25 |
Received By |
fknapp |
Date |
1999-08-14 |
Time |
08:58 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | | | WATER HEATER SHALL BE READILY ACCESSIBLE | | (REFER TO DEFINITIONS IN CHAPT.2 OF | | STANDARD PLUMBING CODE,AND SEC.501.7. | | | | A PAN AND DRAIN ARE REQ'D.FOR THE WATER | | HEATER PER SPC SEC.507.8.1--5O7.8.4. | | | | SHT.A-6.NOTE 11."M"COPPER IS NOT | | PERMITTED FOR U/G USE PER SPC COUNTYWIDE | | AMENDMENTS TO SPC SEC.611.3. | | | | INDICATE TYPE OF GAS AND PIPING BEING | | UTILIZED.STD.GAS CODE SEC.302. | | | | SIZE ALL SECTIONS OF THE GAS RISER | | DIAGRAM.STD. GAS CODE SEC.302. | | | | COMPLY W/TABLES 305.4A, 305.4B OF STD. | | GAS CODE FOR PROPER SIZING OF GAS | | SYSTEM. | | | | THERE ARE 2 COPIES OF SHT.A-6 SHOWING | | DIFFERENT PLBG.DRAWINGS.CLARIFY.SPC | | 104.2.1. | | | | SUBMIT AMOUNT OF TOILET FACILITIES IN | | THE BUILDING.COMPLY W/TABLE 407 OF SPC. | | | | DISHWASHER SHALL BE INDIRECTLY WASTED | | PER SPC SEC.804.2. | | | | FLOOR DRAINS & HANDSINKS SHALL DISCHARGE | | TO GREASY WASTE SYSTEM PER SPC SEC. | | 1004.4. | | | | FLOOR DRAINS ARE NOT PROPERLY VENTED & | | SHALL NOT EXCEED DISTANCES FROM VENT | | PER SPC TABLE 908. | | | | SUBMIT MANUF.SHEETS FOR GAS EQUIP.PER | | STD.GAS CODE SEC.402.1. |
|
|