Plan Review Details - Permit 99071316
Plan Review Stops For Permit 99071316
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-08-25 Cont ID  
Sent By jcaloger Date 1999-08-25 Time 17:17 Rev Time 5.00
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-01-15 Cont ID  
Sent By dpalmer Date 2000-01-15 Time 07:21 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00************ UNSAT ********************
  
 1)NOTE:AS REQ`D BY ART;250-81 OF THE NEC
 ALL OF THE FOOLOWING ARE TO BE INCLUDED
 FOR THE GROUNDING ELECTRODE SYSTEM.
 1.GROUND ROD,COLD WATER PIPE AND BLDG.
 STEEL. ALL THREE NEED TO BE SHOWN ON
 THE RISER DIAGRAM.
  
 2)NOTE: IF CONDUIT BETWEEN MAIN DISC AND
 PANEL IS PVC THEN THERE NEEDS TO BE
 AN EQUIPMENT GROUNDING CONDUCTOR INSTALL
 -ED. SIZE PER 250-95

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-08-17 Cont ID  
Sent By dpalmer Date 1999-07-23 Time 08:04 Rev Time 0.00
Received By dpalmer Date 1999-08-17 Time 16:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-07-26 Cont ID  
Sent By ndenmark Date 1999-07-26 Time 10:36 Rev Time 0.50
Received By ndenmark Date 1999-07-26 Time 10:36 Sent To  
Notes
2001-01-08 00:00:00PROVISO: SMC 501.3 REQUIRES EXHAUST TO
 TERMINATE OUTDOORS. ATTIC DISCHARGE OF
 EXHAUST SHALL BE PROHIBITED

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-08-18 Cont ID  
Sent By tlarge Date 1999-08-18 Time 07:14 Rev Time 0.33
Received By tlarge Date 1999-08-18 Time 07:13 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-08-18 Cont ID  
Sent By tlarge Date 1999-07-23 Time 17:36 Rev Time 0.50
Received By tlarge Date 1999-07-23 Time 17:36 Sent To  
Notes
2001-01-08 00:00:00WASHING MACHINE IS "S" TRAPPED.COMPLY W/
 SPC SEC.901.2.
  
 SHOW FIXTURE CLEARANCES OF WATER CLOSETS
 PER SPC 403.4
  
 CONFIGURATION OF SHOWER ON A-1 DOESN'T
 MATCH SD-1. SPC 104.2.1.