Plan Review Details - Permit 99061517
Plan Review Stops For Permit 99061517
Review Stop E ELECTRICAL
Rev No 4 Status P Date 1999-10-26 Cont ID  
Sent By dpalmer Date 1999-10-26 Time 12:55 Rev Time 0.00
Received By dpalmer Date 1999-10-26 Time 12:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 1999-10-18 Cont ID  
Sent By dpalmer Date 1999-10-18 Time 12:16 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE FIRST SET OF NOTES.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 1999-08-19 Cont ID  
Sent By dpalmer Date 1999-08-19 Time 12:41 Rev Time 0.00
Received By dpalmer Date 1999-08-19 Time 12:41 Sent To  
Notes
2001-01-08 00:00:00SEE FIRST REVISION

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-08-19 Cont ID  
Sent By dpalmer Date 1999-07-06 Time 19:28 Rev Time 0.00
Received By dpalmer Date 1999-07-06 Time 19:28 Sent To P
Notes
2001-01-08 00:00:00*************DENIED*******************
  
 NOTE:NEED TO SUBMIT NEW LOAD
 CACULATIONS AS PER ART:220-3-D-1
 NEED TO SUBMIT EXISTING RISER DIAGRAM
 TO INCLUDE WIRE SIZE,CONDUIT SIZES,
 PANEL SIZE AND GROUNDING SYSTEM.
 NOTE:ART:210-70 WHICH REQ`S LIGHT AT
 MEANS OF EGRESS FROM THE STUDY.
 SAME OUTSIDE LIGHT MAY BE SWITCHED ON
 3-WAY FROM ADJOINING ROOM.
  
 ***************PROVISO******************
  
 1)NOTE:FIRST SET OF PLANS HAD CORRECTION
 FOR MEANS OF EGRESS LIGHTING ART:210-70
 STILL SHOWS NO MEANS OF EGRESS LIGHTING
 AND HOW THEY ARE BEING SWITCHED.
 2)NOTE;1996 NFPA 2-2.1.1.1 REQ`S
 SMOKE DETECTORS INSIDE AND OUTSIDE
 BEDROOMS FOR ANY NEW BUILDING.
 3)NOTE:ART;210-63 REQ`S RECEPTS.FOR A/C
 EQUIPMENT.NOTE LOCATION DRAWN ON PLANS.
 4)NOTE:FIRST SET OF PLANS DID NOT SHOW
 SERVICE CHANGE.THE SUBMITTED RISER
 DIAGRAM IS NOT COMPLETE AS TO THE
 FOLLOWING CODE ARTS;215-5 AND 110-9
 PLEASE SUBMIT TO SHOW RISER CONDUIT
 SIZE,WIRE SIZESUFFICIENT FOR SERVICE.
 NOTE:GROUNDING ELECTRODE CONDUCTOR TO
 GROUND ROD,COLD WATER PIPE AND NEW
 BLDG.STEEL AS PER ART:250-81
 NOTE:SUBMIT AIC RATING OF NEW SERVICE
 FIGURED FROM FAULT CURRENT CALCULATIONS.
  
 PLEASE HAVE ALL THE ABOVE ITEMS DONE
 AND SUBMITTED FOR APPROVAL BEFORE FIRST
 ELECTRICAL INSPECTION.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 1999-11-09 Cont ID  
Sent By jleech Date 1999-11-09 Time 15:46 Rev Time 0.35
Received By jleech Date 1999-11-09 Time 15:46 Sent To  
Notes
2001-01-08 00:00:00REVISED DRAWING.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 1999-11-03 Cont ID  
Sent By jleech Date 1999-10-07 Time 08:42 Rev Time 0.75
Received By jleech Date 1999-10-07 Time 08:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 1999-08-12 Cont ID  
Sent By jleech Date 1999-08-12 Time 15:15 Rev Time 0.50
Received By jleech Date 1999-08-12 Time 15:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-08-18 Cont ID  
Sent By ndenmark Date 1999-07-08 Time 13:47 Rev Time 0.25
Received By jleech Date 1999-07-08 Time 13:47 Sent To  
Notes
2001-01-08 00:00:00NO MECHANICAL INCLUDED, PROVIDE MECH.
 PLANS WITH MECH. PERMIT APPLICATION

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-10-06 Cont ID  
Sent By dpalmer Date 1999-10-26 Time 12:46 Rev Time 0.33
Received By tlarge Date 1999-10-06 Time 07:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-08-19 Cont ID  
Sent By tlarge Date 1999-08-19 Time 17:35 Rev Time 0.50
Received By tlarge Date 1999-08-19 Time 17:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-08-19 Cont ID  
Sent By dpalmer Date 1999-08-19 Time 12:22 Rev Time 0.50
Received By tlarge Date 1999-07-07 Time 07:16 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SANITARY RISER DIAGRAM FOR ALL
 RELOCATED PLBG.WORK.SPC SEC.104.2.1.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-08-18 Cont ID  
Sent By bstaples Date 1999-07-20 Time 13:57 Rev Time 0.75
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00FLORIDA ENERGY SHEETS
 PRODUCT APPROVAL FOR WIDOWS DOORS AND
 ROOF SYSTEMS
 IMPACT RROTECTION INFORMATION GLAZING
 DETAIL STRUCTURAL; CONNEDTION TO OLD BLD
 PLANS DO NOT SCALE REDRAW TO SCALE

Review Stop Z ZONING
Rev No 1 Status P Date 1999-08-16 Cont ID  
Sent By gjoyce Date 1999-06-30 Time 09:13 Rev Time 0.50
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***