Plan Review Stops For Permit 99060720 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2001-05-18 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2001-05-18 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2001-03-02 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2001-03-02 |
Time |
06:53 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-03-02 00:00:00 | APPROVE NEW STAIR AT REAR OF BUILDING |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2001-01-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-01-18 |
Time |
11:13 |
Rev Time |
2.50 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-18 00:00:00 | SBC 104.2.2- ADDITIONAL INFORMATION | | REQUESTED, SHOP DRAWINGS OF STAIRS, | | SHOW ATTACHMENT TO FOUNDATION & STRUC- | | TURE. | | | | SHEET A-4 NORTH ELEVATION- SECOND FLOOR | | WINDOW & FIRST FLOOR FRENCH DOORS THAT | | DO NOT SHOW A 3/4 HR. RATING WILL | | REQUIRE APPROVED OPENING PROTECTION AS | | PER SBC 1006.2.4/1011.2.3. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | (561)659-8096 EX 8412 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2000-11-06 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2000-11-06 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
wlehnhar |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISION NOTES | | ---------------- | | | | EXTERIOR STAIR | | 1] | | STAIR SHALL BE PROTECTED FROM ADJACENT | | PROPERTY,SEE SECTION 1006.2.2 SBC. | | {SEE ATTACHED COPY} | | | | 2] | | PROVIDE CONNECTION DETAIL FOR STAIR AND | | BUILDING TIE IN. | | | | 3] | | SUBMIT HANDRAIL,GUARDRAIL DETAILS. | | | | 4] | | LANDINGS SHALL COMPLY WITH 1007.4 SBC | | {48" OR EQUAL TO WIDTH OF STAIRS} | | | | | | REVIEWED BY: | | LUIS MARTINEZ | | 659-8096 | | EXT. 8456 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2000-10-24 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2000-10-24 |
Time |
07:00 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISION NOT APPROVED | | | | PLANS ARE NOT CLEAR AS TO WHAT HAPPENED | | TO THE REAR ADDITION. | | | | PROVIDE SECOND SET OF ARCH. AND STRUCT. | | PAGES. | | | | STRUCTURAL NOTES,ASCE7-93 AND SBC1994 | | ARE NOT CURRENT. | | | | SUBMIT MANUFACTURES SPECIFICATIONS FOR | | 1HR. GLASS BLOCK. | | | | SUBMIT DETAILS FOR NEW STEEL STAIRS AT | | REAR,DETAILS FOR NEW TRELLIS ON SECOND | | FLOOR ROOF. | | | | REVIEWED BY: | | LUIS MARTINEZ | | 659 8096 | | EXT. 8456 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
1999-08-05 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
1999-07-14 |
Time |
17:45 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-03-29 |
Time |
19:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2001-02-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-02-28 |
Time |
17:52 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-02-28 |
Time |
17:52 |
Sent To |
|
|
Notes |
2001-02-28 00:00:00 | ***************** UNSAT *************** | | | | 1)NOTE: SAME NOTES FROM REVIEW ON | | 1/17/01. | | | | ALL BRANCH CIRCUITS ARE TO BE LABELED ON | | | | PLANS. CIRCUIT #`S ARE TO CORRELATE W/ | | PANEL SCHEDULES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2001-01-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-01-17 |
Time |
20:44 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-01-17 |
Time |
10:46 |
Sent To |
|
|
Notes |
2001-01-17 00:00:00 | ******************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SHOW ALL BRANCH CIRCUIT | | ~#SON PLANS AND CORRELATE WITH PANEL | | SCHEDULE. PLEASE NOTE THAT OUTLETS ARE | | SHOWN ON PLANS WITH NO CIRCUIT #`S?? | | IF OUTLETS BOXES ARE FOR FUTURE? THEN | | STILL MUST HAVE OUTLETS THAT MEET LOCAL | | CODE OF 210-50. PALM BCH COUNTY | | AMENDMENTS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2000-09-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-09-19 |
Time |
20:12 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-09-19 |
Time |
20:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-03-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-03-25 |
Time |
19:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-03-25 |
Time |
19:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
1999-07-13 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
1999-07-13 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2001-02-22 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-02-22 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-02-22 |
Time |
15:48 |
Sent To |
|
|
Notes |
2001-02-22 00:00:00 | 1) EXTERIOR STAIRS TO BE SLIP RESISTANT | | TO PREVENT ACCIDENTS FROM INCLEMENT | | WEATHER. | | 2) THE FIRE RATED WINDOWS AND DOORS | | WHEN INSTALLED MUST BE LABELED AND | | BE INSTALLED IN ACCORDANCE WITH | | NFPA 80, FIRE DOORS AND WINDOWS. | | STAIRS AND FIRE RATED WINDOWS AFTER | | INSTALLATION ARE TO BE INSPECTED BY | | CONSTRUCTION SERVICES AND FIRE RESCUE. | | | | CAPTAIN MIKE CARSILLO | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
F |
Date |
2001-01-26 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-01-26 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-01-26 |
Time |
09:16 |
Sent To |
|
|
Notes |
2001-01-26 00:00:00 | 1) PLEASE PROVIDE INFORMATION ON HOW THE | | STAIR WILL BE CONNECTED AND SUPPORTED. | | 2) PLEASE PROVIDE PRODUCT INFORMATION | | ON THE RATED FIRE DOORS AND WINDOWS | | THAT ARE PLANNED FOR THE SITE. | | 3) PLEASE SUBMIT SHOP DRAWINGS FOR | | STAIR. | | 4) THE BUILDING WILL REQUIRE A FIRE | | ALARM SYSTEM. SEPARATE PLANS AND PERMIT | | REQUIRED PRIOR TO STARTING WORK. | | | | CAPTAIN MIKE CARSILLO | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2000-11-03 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2000-11-02 |
Time |
19:00 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2000-11-02 |
Time |
19:00 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | THIS PLAN REVIEW WAS FOR THE EXIT STAIRS | | PLANNED FOR THE SOUTH SIDE OF THE | | BUILDING. | | | | 1) PLEASE PROVIDE DETAILS ON FIRE RATED | | WINDOWS AND FRAMES TO THIS OFFICE. | | 2) STAIRS ARE TO BE SLIP RESISTANT. | | 3) STAIRS TO MEET ALL OF THE | | REQUIREMENTS FOR NEW STAIRS PER NFPA | | 101, THE LIFE SAFETY CODE, 1985 | | EDITION. THE STAIRS ARE ALLOWED TO BE | | 36" WIDE BASED ON OCCUPANT LOADS OF | | LESS THAN 50 PERSONS. | | 4) PLEASE SUBMIT SHOP DRAWINGS FOR THE | | STAIRS. | | 5) ANY AND ALL OPENINGS WITHIN 10 FEET | | OF THE STAIRS ARE TO BE PROTECTED BY | | FIRE RATED WINDOWS AND DOORS. | | 6) HOW IS STAIR SUPPORTED AND FASTENED | | TO THE BUILDING. | | 7) HANDRAILS AND GUARDS TO COMPLY WITH | | NFPA 101, THE LIFE SAFETY CODE,1985 | | EDITION. | | | | PLANS REVIEWED BY CAPTAIN MIKE CARSILLO | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2000-10-03 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2000-10-03 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2000-10-03 |
Time |
11:32 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1) NO SECOND MEANS OF EGRESS SHOWN FROM | | THIRD FLOOR. PLEASE PROVIDE A SECOND | | MEANS OF EGRESS FROM THE THIRD FLOOR. | | SEVERAL TELEPHONE CONVERSATIONS HAVE | | OCCURRED WITH THE OWNER AND AT LEAST | | TWO MEETINGS HAVE TAKEN PLACE TO | | DISCUSS THIS MATTER. | | 2) PLANS DO NOT SHOW EXIT SIGNS OR | | EMERGENCY LIGHTING EQUIPMENT. | | 3) PLANS DO NOT SHOW RATED WALLS OR | | RATED DOORS. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
1999-07-13 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
1999-07-13 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2001-08-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-08-07 |
Time |
15:47 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2001-08-07 |
Time |
15:47 |
Sent To |
|
|
Notes |
2001-08-07 00:00:00 | AS BUILT DRAWING. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2001-04-27 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-04-27 |
Time |
11:29 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2001-04-27 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
ndenmark |
Date |
2001-01-24 |
Time |
09:40 |
Sent To |
|
|
Notes |
2001-01-24 00:00:00 | REVISION DATED 12-10-00 AS SHOWN M-1, | | M-2 AND M-3 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2000-10-03 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-10-03 |
Time |
13:54 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2000-10-03 |
Time |
13:54 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | THIS MECH APPROVAL IS FOR FUTURE A/C | | EQUIPMENT AND HAS NOT BEEN REVIEWED FOR | | OUTSIDE AIR REQUIREMENTS OR FAN SHUT | | DOWN REQUIREMENTS THIS IS FOR EXHAUST | | FANS AND RELATED DUCT AS SHOWN ON M-1 | | M-2 AND M-3 DATED JUNE 8, 2000 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2000-03-14 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
2000-03-14 |
Time |
15:32 |
Rev Time |
1.00 |
Received By |
cthirben |
Date |
2000-03-14 |
Time |
15:27 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NO A/C PLAN SUBMITTED FOR REVIEW | | MECHANICAL PLANS TO BE SUBMITTED AT TIME | | OF APPLICATION | | * LOOK FOR FIRE RATED WALLS |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
1999-06-14 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
1999-06-14 |
Time |
11:47 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
1999-06-14 |
Time |
11:47 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NO A/C PLANS INCLUDED FOR PLAN REVIEW | | SUBMIT MECHANICAL PLANS AT TIME OF MECH | | PERMIT APPLICATION LOOK FOR RATED WALLS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
8 |
Status |
P |
Date |
2001-04-30 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-04-30 |
Time |
17:12 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2001-04-30 |
Time |
17:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
7 |
Status |
F |
Date |
2001-03-20 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-03-20 |
Time |
09:53 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2001-03-20 |
Time |
09:53 |
Sent To |
|
|
Notes |
2001-03-20 00:00:00 | MINIMUM PLUMBING FIXTURES SHOULD BE FROM | | THE 94 SPC NOT THE 97. MINIMUM BATHROOM | | FACILITYS FOR FEMALES IS 2 W/C AND 2 LAV | | TABLE 407. | | | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT. 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-02-27 |
Time |
17:55 |
Rev Time |
1.50 |
Received By |
jleech |
Date |
2001-02-27 |
Time |
17:55 |
Sent To |
|
|
Notes |
2001-02-27 00:00:00 | DENIED; | | | | 1. MINIMUM PLUMBING FICTURES NOT MET. | | 94 SPC 407. | | BATHROOM FIXTURES REQUIRED ON ALL | | FLOORS AS SHOWN ON ORIGINAL PLANS. | | | | 2.P-4 WATER RISER SHOWS BATHROOMS ON | | SECOND FLOOR. WHATS UP? | | | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT. 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2001-01-19 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-01-19 |
Time |
11:47 |
Rev Time |
2.50 |
Received By |
jleech |
Date |
2001-01-19 |
Time |
11:47 |
Sent To |
|
|
Notes |
2001-01-19 00:00:00 | DENIED; | | | | THE FOLLOWING REVIEW NOTES FROM | | TIMOTHY LARGE HAVE NOT BEEN ADDRESSED. | | | | 1.SUBMIT SQUIRE FOOTAGE OF SPACE FOR | | OCCUPANT LOAD TO ENSURE COMPLIANCE | | WITH SPC TABLE 407. SEE SPC SEC. | | 407.1.3 FOR ALLOWABLE DEDUCTIBLE AREAS | | | | 2.SHOW DIMENSIONS OF TOILET ROOMS COMPLY | | WITH FIG. 28 OFSACBC AND SHOW REQUIRED | | WHEELCHAIR TURNING SPACE IN TOILET | | ROOMS PER FACBC SEC. 4.2.3. | | | | 3.SHOW FIXTURE CLEARANCES FOR HANDICAP | | FIXTURES PER SACBC SEE SEC. 4.15-4.19. | | | | 4.URINAL SHALL BE INSTALLED AT HANDICAP | | HEIGHT AND COMPLY WITH SACBC SEC. 4.18. | | SHOW DETAILS OF ON DRAWINGS. | | | | 5.A MAX. OF 4 FIXTURE UNITS ARE | | PERMITTED ON WET VENTS PER SPC 911.1 | | (SEE URINAL / LAV.) | | SHTS. P-1 AND P-2 WHERE NOT WITH PLANS | | | | 6.INDICATE SLOPE OF STORMWATER PIPING ON | | PLAN. COMPLY WITH TABLES 1108.1 AND | | 1108.2 OF SPC. | | | | NOTE ON PAGE A-1 (PLUMBING ROUGH HAS | | BEEN INSTALLED) DOES NOT ALLOW | | CONTRACTOR TO CIRCUMVENT CODES. | | | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT. 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2000-09-16 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-09-16 |
Time |
05:47 |
Rev Time |
1.00 |
Received By |
tlarge |
Date |
2000-09-16 |
Time |
05:23 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1)SUBMIT SQUARE FOOTAGE OF SPACE FOR | | OCCUPANT LOAD TO ENSURE COMPLIANCE WITH | | SPC TABLE 407.SEE SPC SEC.407.1.3.FOR | | ALLOWED DEDUCTIBLE AREAS. | | | | 2)SHOW DIMENSIONS OF TOILET ROOMS.COMPLY | | W/FIG.28 OF FACBC AND SHOW REQD.WHEEL- | | CHAIR TURNING SPACE IN TOILET ROOMS PER | | FACBC SEC.4.2.3. | | | | 3)SHOW FIXTURE CLEARANCES FOR HANDICAP | | FIXTURES PER FACBC.SEE SECS.4.15-4.19. | | | | 4)URINAL SHALL BE INSTALLED AT H.C. | | HEIGHT AND COMPLY W/FACBC SEC.4.18. | | | | 5)A MAX.OF 4 FIXTURE UNITS ARE PERMITTED | | ON WET VENTS PER SPC 911.1(SEE URINAL/ | | LAV.) | | | | 6)SHOW COMPLETE SIZE OF SCUPPERS AND | | SUBMIT DETAIL.COMPLY W/SPC APPENDIX"A" | | FOR SECONDARY DRAINAGE REQS. | | | | 7)INDICATE SLOPE OF STORMWATER PIPING ON | | PLAN.COMPLY W/TABLES 1108.1 & 1108.2 OF | | SPC. | | | | 8)ROOF DRAINAGE CALCULATIONS SHALL | | INCLUDE 1/2 THE AREA OF ANY VERTICAL | | WALLPER SPC SEC.1108.3. | | | | 9)A DRINKING FOUNTAIN IS REQD.ON THE 2ND | | FLOOR PER SPC TABLE 407. | | | | 10)COMPILE PLANS INTO 2 SETS.IT APPEARS | | THE ARCH. DRAWINGS ARE ONLY IN ONE SET. | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 | | | | 11)VOID OLD PLUMBING SHEETS. | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | QUESTIONS. | | TIMOTHY LARGE | | PLUMBING PLANS EXAMINER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2000-03-18 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-03-18 |
Time |
06:54 |
Rev Time |
1.00 |
Received By |
tlarge |
Date |
2000-03-18 |
Time |
06:53 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SHOW SQ.FOOTAGE OF SPACE FOR OCCUPANT | | LOAD TO ENSURE COMPLIANCE W/SPC TABLE | | 407.SHT.A-1 SHOWS FUTURE FIXTURES. | | | | DRINKING FOUNTAIN SHALL COMPLY W/FACBC | | SEC.4.1.3.(10)(A),4.15.CLEARLY SHOW | | COMPLIANCE W/ABOVE NOTED CODE SECS.ON | | THE PLANS. | | | | SHOW DIMENSIONS OF TOILET ROOMS.COMPLY | | W/FIG.28 OF FACBC AND SHOW REQD.WHEEL- | | CHAIR TURNING SPACE IN TOILET ROOMS PER | | FACBC SEC.4.2.3. | | | | 3" SOIL/WASTE STACKS TO UPPER FLOORS MAY | | BE UNDERSIZED FOR FUTURE BUILDOUT PER | | SPC TABLES 714.1,714.2. | | | | SHOW FIXTURE CLEARANCES FOR H.C.FIXTURES | | PER FACBC. | | | | URINAL SHALL BE INSTALLED AT H.C.HEIGHT | | AND COMPLY W/FACBC SEC.4.18. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
1999-07-28 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
1999-07-28 |
Time |
07:41 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PROVISO | | (1) WATER HEATER TP 3/4", PAN DRAIN 1" | | RUN SEPERATELY TO THE OUT SIDE 6" | | ABOVE GRADE.SEC.507.8.4&507.8.2. | | (2) ALL PUBLIC REST RM'S TO HAVE HOT | | WATERFEC 97 SEC412.1 ABD.2.3.2 | | (3) REVISIONS TO FOLLOW AS PER | | JAY SAUNDRERS ARCH. | | END OF COMMENTS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
1999-08-05 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-07-13 |
Time |
13:01 |
Rev Time |
1.00 |
Received By |
sgraham |
Date |
1999-08-05 |
Time |
11:07 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | INSTALLATION OF HANDICAP PLBG.FIXTURES | | SHALL COMPLY W/F.A.C.B.C.1997 EDITION. | | | | SIZE OF HANDICAP STALLS IN RESTROOMS | | SHALL COMPLY W/F.A.C.B.C.SEC.4.17.3.1997 | | EDITION.(SEE EXCEPTION:NEW CONSTRUCTION) | | | | INDICATE OCCUPANT LOAD ON PLAN TO | | DETERMINE MIN.PLBG.FIXTURE REQ'S.PER | | SEC.407 AND TABLE 407 OF STD.PLBG.CODE. | | | | SUBMIT SANITARY AND WATER ISOMETRICS | | THAT REFLECT ENTIRE SCOPE OF PLBG.WORK | | TO BE DONE PER SPC SEC.104.2.1. | | | | FLOOR DRAINS ARE REQ'D.IN TOILET ROOMS | | PER SPC SEC.409.4.1.1. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
1999-07-19 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
1999-07-19 |
Time |
10:20 |
Rev Time |
0.75 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|