Plan Review Details - Permit 99060111
Plan Review Stops For Permit 99060111
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-16 Cont ID  
Sent By dpalmer Date 1999-06-16 Time 14:33 Rev Time 0.00
Received By dpalmer Date 1999-06-16 Time 14:33 Sent To  
Notes
2001-01-08 00:00:00****************PROVISO*****************
  
 NEED FAULT CURRENT CALCULATIONS AND
 AIC RATING TO BE DRAWN ON PLANS.
 ART.215-5
 NOTE:SMOKE DETECTORS REQ`D INSIDE
 AND OUTSIDE BEDROOMS.
 NOTE:GROUNDING ELECTRODE SYSTEM TO GO
 TO BLDG.STEEL ALSO.
  
 NEED THE ABOVE INFORMATION BEFORE
 ROUGH INSPECTION IS CALLED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-06-26 Cont ID  
Sent By jleech Date 1999-06-26 Time 14:44 Rev Time 0.50
Received By jleech Date 1999-06-26 Time 14:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-01-19 Cont ID  
Sent By tlarge Date 2000-01-19 Time 06:41 Rev Time 0.25
Received By tlarge Date 2000-01-19 Time 06:41 Sent To  
Notes
2001-01-08 00:00:00REVISED PLBG.RISER.

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-08-11 Cont ID  
Sent By tlarge Date 1999-08-11 Time 11:10 Rev Time 0.50
Received By tlarge Date 1999-08-11 Time 11:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-08-11 Cont ID  
Sent By tlarge Date 1999-06-30 Time 10:00 Rev Time 0.65
Received By tlarge Date 1999-06-30 Time 07:46 Sent To  
Notes
2001-01-08 00:00:00MAX.2 WATER CLOSETS PERMITTED ON 3"BLDG.
 DRAIN. SPC TABLE 714.1,FOOTNOTE #3.
  
 SUBMIT SANITARY RISER THAT COMPLIES W/
 STANDARD PLBG.CODE.
  
 LAYOUT OF SANITARY RISER SHALL CORRELATE
 W/THE FLOOR PLAN.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-08-03 Cont ID  
Sent By jcaloger Date 1999-08-03 Time 12:22 Rev Time 2.00
Received By jcaloger Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1999-06-07 Cont ID  
Sent By gjoyce Date 1999-06-07 Time 17:21 Rev Time  
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***