Plan Review Details - Permit 99041194
Plan Review Stops For Permit 99041194
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-08-16 Cont ID  
Sent By bstaples Date 1999-08-16 Time 08:08 Rev Time 30.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00CHECK LIST ON PLANS ISSUED WITH
 PROVISO.

Review Stop E ELECTRICAL
Rev No 10 Status P Date 2000-09-18 Cont ID  
Sent By dpalmer Date 2000-09-18 Time 20:56 Rev Time 0.00
Received By dpalmer Date 2000-09-18 Time 20:56 Sent To  
Notes
2001-01-08 00:00:00REV #11

Review Stop E ELECTRICAL
Rev No 9 Status P Date 2000-09-18 Cont ID  
Sent By dpalmer Date 2000-09-18 Time 20:50 Rev Time 0.00
Received By dpalmer Date 2000-09-18 Time 20:50 Sent To  
Notes
2001-01-08 00:00:00REV #13

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2000-09-18 Cont ID  
Sent By dpalmer Date 2000-09-18 Time 20:45 Rev Time 0.00
Received By dpalmer Date 2000-09-18 Time 20:45 Sent To  
Notes
2001-01-08 00:00:00REV #14

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2000-07-06 Cont ID  
Sent By jleahy Date 2000-07-06 Time 15:34 Rev Time 2.30
Received By jleahy Date 2000-07-06 Time 15:33 Sent To  
Notes
2001-01-08 00:00:00PAGES CE401,02,04, AND 05 HAVE ONLY HALF
 OF THE NOTES SHOWING ON THE PLAN!!!!!!!

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2000-06-27 Cont ID  
Sent By jleahy Date 2000-06-27 Time ]':35 Rev Time 1.00
Received By jleahy Date 2000-06-27 Time 09:34 Sent To  
Notes
2001-01-08 00:00:00REV.#10

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2000-03-15 Cont ID  
Sent By jleahy Date 2000-03-15 Time 10:13 Rev Time 1.00
Received By jleahy Date 2000-03-15 Time 10:12 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 1999-12-20 Cont ID  
Sent By jleahy Date 1999-12-20 Time 12:37 Rev Time 0.00
Received By jleahy Date 1999-12-20 Time 14:08 Sent To  
Notes
2001-01-08 00:00:006-THIS PLAN IS OK BUT APPROVAL IS
 PENDING.CITY STILL NEEDS A PLAN
 THAT SHOWS THE BOUNDARIES FOR POWER
 DISTRIBUTION IN ALL THESE CITY PLACE
 BUILDINGS WITH MORE THAN ONE SERVICE
  
 2-PLAN WILL BE APPROVED UPON APPROVAL
 OF POWER DISTRIBUTION PLAN!!!!!!!!!
  
 3-POWER PLAN CAME IN ON 12-20-99 JL
  
  
  
  
  
  
  
  
  
  
  
  
  
 POWER PLAN CAME IN ON 12-20-.99

Review Stop E ELECTRICAL
Rev No 3 Status P Date 1999-12-01 Cont ID  
Sent By jleahy Date 1999-12-01 Time 13:53 Rev Time 1.30
Received By jleahy Date 1999-12-01 Time 13:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 1999-11-05 Cont ID  
Sent By jleahy Date 1999-11-05 Time 12:32 Rev Time 1.30
Received By jleahy Date 1999-11-05 Time 12:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-08-16 Cont ID  
Sent By bstaples Date 1999-08-16 Time 08:09 Rev Time 5.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLAN APPROVED BY JAKE LEAHY SEE PERMIT
 APPLICATION.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2000-09-27 Cont ID  
Sent By mcarsill Date 2000-09-27 Time 16:05 Rev Time 0.00
Received By mcarsill Date 2000-09-27 Time 16:05 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2000-09-18 Cont ID  
Sent By mcarsill Date 2000-09-18 Time 13:46 Rev Time 0.00
Received By mcarsill Date 2000-09-18 Time 13:46 Sent To  
Notes
2001-01-08 00:00:001) 3 HOUR FIRE DOORS REQUIRED BETWEEN
 C RETAIL AND MUVICO BUILDING. DOOR
 FRAMES ARE ALSO TO MEET THESE
 REQUIREMENTS.
 2) DOUBLE DOORS AT CORRIDOR 101 TO BE
 LABELED NO EXIT PER CODE REQUIREMENTS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-04-10 Cont ID  
Sent By bstaples Date 2000-04-10 Time 13:19 Rev Time 0.20
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00FIRE EXTINGUISHER CABNETS OK M. CARSILLO

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1999-09-10 Cont ID  
Sent By bstaples Date 1999-09-10 Time 13:40 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2001-02-08 Cont ID  
Sent By ndenmark Date 2001-02-08 Time 13:30 Rev Time 0.50
Received By ndenmark Date 2001-02-08 Time 13:30 Sent To  
Notes
2001-02-08 00:00:00FINAL AS BUILTS

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-05-22 Cont ID  
Sent By ndenmark Date 2000-05-22 Time 07:48 Rev Time 1.00
Received By ndenmark Date 2000-05-22 Time 07:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-01-31 Cont ID  
Sent By ndenmark Date 2000-01-31 Time 07:11 Rev Time 1.00
Received By ndenmark Date 2000-01-31 Time 07:11 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 ALL RECIRCULATING AIR SYSTEMS WITH A FAN
 CAPACITY OF 2000 CFM OR LESS, BUT SERV-
 ING AN AREA USED FOR EGRESS, SHALL AUTO-
 MATIC SHUTDOWN 1997 SMC 406.2

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-08-16 Cont ID  
Sent By bstaples Date 1999-08-16 Time 08:12 Rev Time 5.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00PERMIT APPROVED BY NANCY DENMARK SEE
 PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 8 Status P Date 2000-11-04 Cont ID  
Sent By tlarge Date 2000-11-04 Time 11:20 Rev Time 1.00
Received By tlarge Date 2000-11-04 Time 11:20 Sent To  
Notes
2001-01-08 00:00:00FINAL AS-BUILTS.

Review Stop P PLUMBING
Rev No 7 Status P Date 2000-10-01 Cont ID  
Sent By tlarge Date 2000-10-01 Time 08:57 Rev Time 1.00
Received By tlarge Date 2000-10-01 Time 07:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status P Date 2000-05-06 Cont ID  
Sent By tlarge Date 2000-05-06 Time 12:05 Rev Time 1.50
Received By tlarge Date 2000-05-06 Time 12:05 Sent To  
Notes
2001-01-08 00:00:00*******************PROVISO**************
 SHT.P3.06-COL.10 BETWEEN F & G.-CONDEN-
 SATE SHALL NOT CONNECT TO STORM SYSTEM
 INSIDE BLDG.SPC SEC.804.3,807.2.
  
 SHT.CMP-3.01-VTR IS LOCATED WITHIN 10'OF
 OIA #3.COMPLY W/SPC SEC 905.5.

Review Stop P PLUMBING
Rev No 5 Status P Date 2000-03-21 Cont ID  
Sent By tlarge Date 2000-03-21 Time 11:02 Rev Time 1.00
Received By tlarge Date 2000-03-21 Time 11:02 Sent To  
Notes
2001-01-08 00:00:00******************PROVISO***************
 DESIGN OF GREASE INTERCEPTOR SHALL
 COMPLY W/ CITY OF WEST PALM BEACH
 UTILITIES REQS.CONTACT R.COMPO AT
 (561) 835-7423.
  
 SHT.CP-3.06-CONNECTION OF CONDENSATE TO
 STORM DRAIN SHALL BE BY INDIRECT
 CONNECTION PER SPC SEC.804.3,807.2.
  
 FLOOR DRAINS AT COMPACTOR SHALL BE A
 MAXIMUM OF 15' FROM THE VENT,NOT A MIN.
 OF 15'.COUNTYWIDE AMENDMENTS TO SPC SEC.
 908.1,FOOTNOTE #1.
  
 SUBMIT DETAIL OF GAS MANIFOLD.THE
 MANIFOLD IS LOCATED NEXT TO A
 TRANSFORMER PAD THAT WILL SERVE EQUIP-
 MENT THAT MAY BE CONSIDERED A SOURCE OF
 IGNITION.SUBMIT INFO ON EQUIPMENT BEING
 LOCATED ON PAD.COMPLY W/NFPA 54,SEC.1.7.
  
 SHT.CMP-3.01-VTR IS LOCATED WITHIN 10'
 OF OAI-COMPLY W/SPC SEC.905.5.

Review Stop P PLUMBING
Rev No 4 Status F Date 2000-03-17 Cont ID  
Sent By tlarge Date 2000-03-17 Time 08:40 Rev Time 2.75
Received By tlarge Date 2000-03-17 Time 08:39 Sent To  
Notes
2001-01-08 00:00:00DESIGN OF GREASE INTERCEPTOR SHALL
 COMPLY W/CITY OF WPB UTILITIES REQS.
 CONTACT RODNEY COMPO AT (561)835-7423.
  
 SHT.CP-3.06.CONNECTION OF CONDENSATE TO
 STORM DRAIN SHALL BE BY INDIRECT
 CONNECTIONS PER SPC 804.3.,807.2,
  
 FLOOR DRAINS AT COMPACTOR SHALL BE A
 MAXIMUM OF 15' FROM THE VENT,NOT A MIN.
 OF 15'.COUNTYWIDE AMENDMENTS TO SPC SEC.
 908.1,FOOTNOTE #1.
  
 SUBMIT DETAIL OF GAS MANIFOLD.THE
 MANIFOLD IS LOCATED NEXT TO A
 TRANSFORMER PAD THAT WILL SERVE
 EQUIPMENT THAT MAY BE CONSIDERED A
 SOURCE OF IGNITION.SUBMIT INFO ON EQUIP.
 BEING LOCATED ON PAD.COMPLY W/NFPA 54
 SEC.1.7.
  
 SHT.CMP-3.01-VTR IS LOCATED WITHIN 10'
 OF OAI-3 .COMPLY W/SPC SEC.905.5.
  
 NOTE:EARLIER REVISIONS OF THESE PLANS
 HAVE BEEN APPROVED W/PROVISOS ON 3/21/00
 BY T.LARGE AND THE LATER REVISIONS SHALL
 BE CORRECTED PRIOR TO APPROVAL.

Review Stop P PLUMBING
Rev No 3 Status F Date 2000-01-28 Cont ID  
Sent By tlarge Date 2000-01-28 Time 12:16 Rev Time 1.50
Received By tlarge Date 2000-01-28 Time 12:16 Sent To  
Notes
2001-01-08 00:00:00CAPACITY OF GREASE INTERCEPTOR SHALL BE
 DETERMINED BY CITY OF WPB UTILITIES.
 CONTACT RODNEY COMPO AT (561)835-7423
 FOR INFORMATION.
  
 DESIGN OF GREASE INTERCEPTOR SHALL
 COMPLY W/BOARD OF HEALTH REQS.
 (561)355-3022.(SEE SHT.C-MP3.04)
  
 SHT.C-P3.03-VENT FOR FLOOR DRAIN
 BY COMPACTOR SHALL RISE 6" ABOVE FLOOD
 RIM LEVEL OF FIXTURE BEFORE OFF SETTING
 PER SPC 906.2.1
  
 SUBMIT DETAIL OF GAS MANIFOLD.THE
 MANIFOLD IS LOCATED NEXT TO A
 TRANSFORMER PAD.COMPLY W/NFPA 54 SECS.
 (SOURCES OF IGNITION)1.7,(NFPA HAS BEEN
 CONTACTED FOR A CODE EXPLANATION TO
 DETERMINE IF A CODE VIOLATION EXISTS.)

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-11-18 Cont ID  
Sent By tlarge Date 1999-11-18 Time 20:33 Rev Time 1.50
Received By tlarge Date 1999-11-18 Time 20:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-05-13 Cont ID  
Sent By pschmitz Date 1999-05-13 Time 15:46 Rev Time 2.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO:GREASE TRAP,DETAIL7-C-MP3.04
 2 MAN HOLE COVERS REQUIRED.

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By bstaples Date 1999-08-16 Time 13:29 Rev Time 0.25
Received By bstaples Date   Time   Sent To  
Notes
***NONE***