Plan Review Details - Permit 99031479
Plan Review Stops For Permit 99031479 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2000-03-14 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
1999-07-21 |
|
|
Cont ID |
|
Sent By |
jcaloger |
Date |
1999-05-10 |
Time |
14:22 |
Rev Time |
0.25 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *****************DENIED**************** | | NEED TO GIVE MORE DETAILED INFORMATION | | ON ALL ELECTRICAL.DRAW IN SWITCH LEGS | | SMOKE DETECTORS REQ`D INSIDE AND OUTSIDE | | BEDROOMS. | | LIGHTS REQ`D BY 210-70 AT MEANS OF | | EGRESS. | | NOTE:210-8-A-6 RECEPTS.SERVING KITCHEN | | COUNTER SPACE. | | YOU SHOW 6-GANG BOX BUT ONLY SHOW ONE | | SWITCH. | | ALSO PLEASE HAVE ELECTRICAL RISER | | DIAGRAM AND LOAD CALCULATIONS DRAWN | | ON SAME PAGE. | | PLEASE DRAW IN NEW PANEL SCHED.WITH | | AIC RATING OF EQUIPMENT. | | 215-5 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
1999-07-21 |
|
|
Cont ID |
|
Sent By |
jcaloger |
Date |
1999-05-10 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
bstaples |
Date |
1999-07-19 |
Time |
16:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
1999-07-21 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
1999-07-02 |
Time |
13:44 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
1999-07-02 |
Time |
13:44 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | CLEARLY SHOW ALL SHOWER DIMENSIONS ON | | PLAN.(L X W).MIN.1024 SQ.IN.REQ'D & MIN. | | 30" WIDE.PER SPC SEC.408.8.1,409.8.2.1 | | OF COUNTYWIDE AMEND. | | | | SHOW LOCATION OF WASHING MACHINE OUTLET | | SPC 104.2.1. | | | | SHOW LOCATION OF WATER HEATERS.SPC | | 401.2.1 | | | | SUBMIT SANITARY RISER DIAGRAM THAT | | COMPLIES W/STD.PLBG.CODE. | | | | SHOW FIXTURE CLEARANCES OF W.C'S ON PLAN | | PER SPC SEC.403.4. | | | | VENTING OF WATER CLOSETS SHALL COMPLY | | W/COUNTYWIDE AMEND.TO PLBG.CODE SEC. | | 911.1.3. | | | | KIT.SINK NOT PROPERLY VENTED.SPC 901.2. | | | | SHOW ALL FIXTURES ON SAN.RISER.SPC 104.2 | | | | DRY VENTS NOT PERMITTED. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
1999-07-21 |
|
|
Cont ID |
|
Sent By |
jcaloger |
Date |
1999-05-10 |
Time |
14:22 |
Rev Time |
0.65 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ISOMETRTIC SHALL CLEARLY REFLECT SCOPE | | OF WORK BEING PERFORMED.(ALL AREAS ARE | | NOT SHOWN.)SPC 104.2.1. | | | | IDENTIFY ALL FIXTURES ON SAN.RISER. | | SPC 104.2.1. | | | | CLEARLY SHOW ALL DIMENSIONS OF TOILET | | AND BATH ROOMS AND SHOW ALL FIXTURE | | CLEARANCES.SPC 104.2.1,403.4. | | | | SHOW ALL SHOWER DIMENSIONS ON PLANS. | | SPC 408.8.1. | | | | CLEARLY SHOW ON THE PLANS WHAT PLBG.IS | | NEW AND WHAT IS EXISTING.SPC 104.2.1. | | | | SHOW LOCATION OF WASHING MACHINE PER | | TABLE 407 OF SPC. | | | | REJECTED AGAIN ON 6/18/99-CORRECTIONS | | NOT DONE. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
1999-07-21 |
|
|
Cont ID |
|
Sent By |
jcaloger |
Date |
1999-05-10 |
Time |
14:22 |
Rev Time |
1.50 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SEE PERMIT NOTES NO P, M OR E PERMITTED | | MUST SUBMIT PERMIT AND PLANS FOR P,E &E |
|
|
|