Plan Review Details - Permit 99020716
Plan Review Stops For Permit 99020716
Review Stop E ELECTRICAL
Rev No 1 Status P Date 1999-06-16 Cont ID  
Sent By jgomez Date 1999-06-16 Time 13:33 Rev Time 0.00
Received By jgomez Date 1999-10-07 Time 10:04 Sent To  
Notes
2001-01-08 00:00:00APPLICATION SIGNED BY JAKE

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-06-16 Cont ID  
Sent By ndenmark Date 1999-06-16 Time 13:22 Rev Time 0.50
Received By ndenmark Date 1999-06-16 Time 13:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-03-13 Cont ID  
Sent By pschmitz Date 1999-03-13 Time 09:36 Rev Time 0.75
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 7 Status P Date 2000-04-04 Cont ID  
Sent By jgomez Date 2000-04-04 Time 18:00 Rev Time 0.25
Received By jgomez Date 2000-04-04 Time 18:00 Sent To  
Notes
2001-01-08 00:00:00NOTES:
 PERMIT TYPE ON SCREEN #1 WAS CHANGED
 FROM BLD-RES TO MASTER TO ALLOW PERMITS
 TO BE PRINTED. ORIGINAL PERMIT
 APPLICATION WAS SUBMITTED FOR A BLD-RES
 AND LATER ON THE APPLICANT WANTED TO GET
 A MASTER PERMIT. SUCH CHANGE WAS NEVER
 REVISED ON THIS SCREEN. THEREFORE, I
 HAD TO CHANGE THE PERMIT TYPE TO AVOID
 MORE CONFUSION AND BE ABLE TO REFER TO
 THIS MASTER NUMBER AS THE MASTER FOR
 TYPE II MODEL, INCLUDING STORM PANELS.
 JG. 4-4-00.

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status F Date 1999-10-28 Cont ID  
Sent By jgomez Date 1999-10-28 Time 14:33 Rev Time 0.50
Received By jgomez Date 1999-10-28 Time 14:33 Sent To  
Notes
2001-01-08 00:00:00 
 CHECKLIST FOR PROVISO GIVEN ON 10/15/99:
 1-PROVIDE COMPLETE SPECIFICATIONS AND
 DETAILS FOR CONSTRUCTION OF CEILING AT
 PORCH. SEC. 104.2.2 CITY AMENDMENTS.
 NOTE: ALCOA RIGID VINYL SIDING AND
 SOFFIT PRODUCT APPROVAL DOESN'T
 INCLUDE INSTALLATION AT PORCHE'S
 CEILING.
 2-SPECIFY ATTIC VENTILATION FOR NEW
 SOFFIT SYSTEM AS PER SEC 2309.7 SBC/94

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 1999-10-15 Cont ID  
Sent By jgomez Date 1999-10-15 Time 14:35 Rev Time 0.25
Received By jgomez Date 1999-10-15 Time 14:31 Sent To  
Notes
2001-01-08 00:00:00VINYL SIDING PRODUCT APPROVAL PROVISO:
 1-PROVIDE MANUFACTURER'S INSTALLATION
 SPECIFICATIONS.
 2-PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR INSTALLATION AT
 PORCH'S CEILING.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 1999-10-07 Cont ID  
Sent By jgomez Date 1999-10-07 Time 17:51 Rev Time 0.30
Received By jgomez Date 1999-10-07 Time 17:51 Sent To  
Notes
2001-01-08 00:00:00APPROVED ENGINEERED TRUSSES. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 1999-10-07 Cont ID  
Sent By jgomez Date 1999-10-07 Time 10:05 Rev Time 0.25
Received By jgomez Date 1999-10-07 Time 10:05 Sent To  
Notes
2001-01-08 00:00:00ROOF SHINGLES PRODUCT APPROVAL. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 1999-09-20 Cont ID  
Sent By jgomez Date 1999-09-20 Time 12:53 Rev Time 1.30
Received By jgomez Date 1999-09-20 Time 12:53 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST - MODEL II:
 1-ENGINEER OF RECORD TO REVIEW ALL TRUSS
 DRAWINGS PRIOR TO SUBMITTAL.
 2-ENGINEERED TRUSSES:
 *REVISE MEAN ROOF HEIGHT.
 *CLARIFY NOTE SAYING THAT IF PORCHES
 EXIST, THEY ARE NOT EXPOSED TO WIND.
 WHY?
 WHAT DOES DOL STANDS FOR? DEFLECTION?
 *REVISE DESIGN CRITERIA DATA ON TRUSS
 LAYOUT. IT DOESN'T MATCH DESIGN
 CRITERIA ON ENGINEERED TRUSSES.
 *WHY NOT ALL ENGINEERED TRUSSES SHOW
 THE DESIGN CRITERIA USED TO DETERMINE
 ALL LOADS?.
 3-CHECK/REVISE ALL HURRICANE ANCHORS
 SPECIFIED. WILL THEY RESIST THE
 HORIZONTAL LOADS CALCULATED BY THE
 ENGINEERED TRUSSES.
 4-PROVIDE A COMPLETE DETAIL AND SPECS
 FOR ALUMINUM CEILING AT PORCH.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-04-06 Cont ID  
Sent By jgomez Date 1999-04-06 Time 14:07 Rev Time 0.00
Received By jgomez Date   Time   Sent To O
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO