Plan Review Stops For Permit 99020714 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2000-04-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2000-04-04 |
Time |
18:40 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2000-04-04 |
Time |
18:40 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SEE MASTER PERMIT PLANS FOR APPROVAL | | BY JAKE LEAHY. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
1999-03-08 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
1999-03-08 |
Time |
14:34 |
Rev Time |
0.25 |
Received By |
ndenmark |
Date |
1999-03-08 |
Time |
14:34 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ****************PROVISO***************** | | RETURN AIR LOCATION IS WITHIN 10 FEET OF | | THE COOKING EQUIPMENT. THIS IS ACCEPT- | | ABLE IN THE CURRENT CODE, IT IS EXPECTED | | THAT THE 1997 SMC WILL BE ADOPTED JUNE | | 1999, AND THIS LOCATION WILL NOT BE AC- | | CEPTED AT THAT TIME. ANY PERMITS ISSUED | | AFTER WIL NEED TO COMPLY WITH 1997 SMC | | 409 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
1999-03-13 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
1999-03-13 |
Time |
09:40 |
Rev Time |
0.75 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
7 |
Status |
P |
Date |
2000-04-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2000-04-04 |
Time |
18:35 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2000-04-04 |
Time |
18:35 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NOTES: | | PERMIT TYPE ON SCREEN #1 WAS CHANGED | | FROM BLD-RES TO MASTER TO ALLOW PERMITS | | TO BE PRINTED. ORIGINAL PERMIT | | APPLICATION WAS SUBMITTED FOR A BLD-RES | | AND LATER ON THE APPLICANT WANTED TO GET | | A MASTER PERMIT. SUCH CHANGE WAS NEVER | | REVISED ON THIS SCREEN. THEREFORE, I | | HAD TO CHANGE THE PERMIT TYPE TO AVOID | | MORE CONFUSION AND BE ABLE TO REFER TO | | THIS MASTER NUMBER AS THE MASTER FOR | | TYPE IV MODEL, INCLUDING STORM PANELS. | | J.G. 4-4-00. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
6 |
Status |
F |
Date |
1999-10-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
1999-10-28 |
Time |
18:39 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
1999-10-28 |
Time |
18:39 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | | | CHECKLIST FOR PROVISO GIVEN ON 10/15/99: | | 1-PROVIDE COMPLETE SPECIFICATIONS AND | | DETAILS FOR CONSTRUCTION OF CEILING | | AT PORCH. | | NOTE:ALCOA RIGID VINYL SIDING AND | | SOFFIT PRODUCT APPROVAL DOESN'T | | INCLUDE INSTALLATION AT PORCHE'S | | CEILING. | | 2-SPECIFY ATTIC VENTILATION FOR NEW | | SOFFIT SYSTEM AS PER SEC 2309.7 SBC/94 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
P |
Date |
1999-10-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
1999-10-15 |
Time |
14:50 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
1999-10-15 |
Time |
14:49 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | VINYL SIDING PRODUCT APPROVAL PROVISO: | | 1-PROVIDE MANUFACTURER'S INSTALLATION | | SPECIFICATIONS. | | 2-PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS FOR INSTALLATION AT | | PORCH'S CEILING. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
P |
Date |
1999-10-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
1999-10-07 |
Time |
18:18 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
1999-10-07 |
Time |
18:18 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED ENGINEERED TRUSSES. JG. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
1999-09-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
1999-09-30 |
Time |
13:53 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISIONS: | | DELETION OF INTERIOR BEARING WALL, | | REVISION OF GIRDER TRUSS SUPPORT. | | MODEL V - PERMIT #S: | | 99-06-0200 | | 0197 | | 0234 | | 0238 | | 0188 | | 0219 | | 0202 | | 0237 | | 0217 | | 0220 | | 0218 | | 0211 | | 0236 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
1999-09-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
1999-09-20 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
1999-09-20 |
Time |
10:25 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | CHECKLIST - MODEL IV: | | 1-ENGINEER OF RECORD TO REVIEW ALL TRUSS | | DRAWINGS PRIOR TO SUBMITTAL. | | 2-ENGINEERED TRUSSES: | | *CHECK/REVISE MEAN ROOF HEIGHT. | | *CLARIFY NOTE #1 ON ENGINEERED ROOF | | TRUSSES. EG: IF PORCHES EXIST, THEY | | ARE NOT EXPOSED TO WIND. WHY? | | WHAT DOES DOL STANDS FOR?DEFLECTION? | | *REVISE DESIGN CRITERIA DATA ON TRUSS | | LAYOUT. IT DOESN'T MATCH DESIGN | | CRITERIA ON ENGINEERED TRUSSES. | | *REVISE DIMENSIONS OF BUILDINGS SHOWN | | ON ENGINEERED TRUSSES. | | *WHY NOT ALL ENGINEERED TRUSSES SHOW | | THE DESIGN CRITERIA USED TO DETERMINE | | ALL THE LOADS. | | 3-CHECK/REVISE ALL HURRICANE ANCHORS | | SPECIFIED. WILL THEY RESIST THE | | HORIZONTAL LOADS CALCULATED BY THE | | ENGINEERED TRUSSES. | | 4-PROVIDE A COMPLETE DETAIL FOR ALUMINUM | | CEILINGS AT PORCH. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
1999-04-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
1999-04-08 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
|
Time |
|
Sent To |
O |
|
Notes |
2001-01-08 00:00:00 | APPROVED WITH PROVISO |
|
|