Plan Review Details - Permit 99020713
Plan Review Stops For Permit 99020713
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-04-04 Cont ID  
Sent By jgomez Date 2000-04-04 Time 18:58 Rev Time 0.00
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE MASTER PLANS FOR APPROVAL BY JAKE,

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 1999-03-08 Cont ID  
Sent By ndenmark Date 1999-03-08 Time 13:47 Rev Time 0.50
Received By ndenmark Date 1999-03-08 Time 13:47 Sent To  
Notes
2001-01-08 00:00:00**********PROVISO***********************
 RETURN AIR LOCATION IS WITHIN 10 FEET OF
 COOKING EQUIPMENT, THIS IS ACCEPTABLE IN
 THE 1994 SMC, IT IS EXPECTED THAT THE
 1997 SMC WILL BE ADOPTED IN JUNE, 1999
 AND THIS LOCATION WILL NO LONGER BE AC-
 CEPTABLE PER 1997 SMC 409. ANY PERMITS
 ISSUED AFTER THIS WILL REQUIRE COMPLIANC
 WITH THIS SECTION OF THE CODE

Review Stop P PLUMBING
Rev No 1 Status P Date 1999-03-13 Cont ID  
Sent By pschmitz Date 1999-03-13 Time 09:41 Rev Time 0.75
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 8 Status P Date 2000-04-04 Cont ID  
Sent By jgomez Date 2000-04-04 Time 19:00 Rev Time 0.25
Received By jgomez Date 2000-04-04 Time 18:59 Sent To  
Notes
2001-01-08 00:00:00NOTES:
 PERMIT TYPE ON SCREEN #1 WAS CHANGED
 FROM BLD-RES TO MASTER TO ALLOW PERMITS
 TO BE PRINTED. ORIGINAL PERMIT
 APPLICATION WAS SUBMITTED FOR A BLD-RES
 AND LATER ON THE APPLICANT WANTED TO GET
 A MASTER PERMIT. SUCH CHANGE WAS NEVER
 REVISED ON THIS SCREEN. THEREFORE, I HAD
 TO CHANGE THE PERMIT TYPE TO AVOID MORE
 CONFUSION AND BE ABLE TO REFER TO THIS
 MASTER AS THE MASTER FOR TYPE V MODEL,
 INCLUDING STORM PANELS. J.G. 4-4-00.

Review Stop R ROOF PLAN REVIEW
Rev No 7 Status F Date 1999-10-28 Cont ID  
Sent By jgomez Date 1999-10-28 Time 18:42 Rev Time 0.50
Received By jgomez Date 1999-10-28 Time 18:41 Sent To  
Notes
2001-01-08 00:00:00 
 CHECKLIST FOR PROVISO GIVEN ON 10/15/99:
 1-PROVIDE COMPLETE SPECIFICATIONS AND
 DETAILS FOR CONSTRUCTION OF CEILING AT
 PORCH. SEC 104.2.2 CITY AMENDMENTS.
 NOTE: ALCOA RIGID VINYL SIDING AND
 SOFFIT PRODUCT APPROVAL DOESN'T
 INCLUDE INSTALLATION AT PORCHE'S
 CEILING.
 2-SPECIFY ATTIC VENTILATION FOR NEW
 SOFFIT SYSTEM AS PER SEC 2309.7 SBC/94

Review Stop R ROOF PLAN REVIEW
Rev No 6 Status P Date 1999-10-15 Cont ID  
Sent By jgomez Date 1999-10-15 Time 14:54 Rev Time 0.25
Received By jgomez Date 1999-10-15 Time 14:54 Sent To  
Notes
2001-01-08 00:00:00VINYL SIDING PRODUCT APPROVAL PROVISO:
 1-PROVIDE MANUFACTURER'S INSTALLATION
 SPECIFICATIONS.
 2-PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR INSTALLATION AT
 PORCH'S CEILING.

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 1999-10-08 Cont ID  
Sent By jgomez Date 1999-10-08 Time 13:24 Rev Time 0.75
Received By jgomez Date 1999-10-08 Time 13:24 Sent To  
Notes
2001-01-08 00:00:00APPROVED TRUSSES. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 1999-10-07 Cont ID  
Sent By jgomez Date 1999-10-07 Time 09:48 Rev Time 0.25
Received By jgomez Date 1999-10-07 Time 09:48 Sent To  
Notes
2001-01-08 00:00:00ROOF SHINGLES PRODUCT APPROVAL. JG.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 1999-09-30 Cont ID  
Sent By jgomez Date 1999-09-30 Time 13:43 Rev Time 0.25
Received By jgomez Date   Time   Sent To  
Notes
2001-01-08 00:00:00REVISIONS:
 TYPICAL FLOOR TO FLOOR TIE INSTALLATION
  
 MODEL V - PERMIT #S:
 99-06-0223
 0224
 0204
 0216
 0225
 0191
 0195
 0214

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 1999-09-25 Cont ID  
Sent By jgomez Date 1999-09-18 Time 14:21 Rev Time 1.30
Received By jgomez Date 1999-09-18 Time 14:20 Sent To  
Notes
2001-01-08 00:00:00CHECKLIST - MODEL V:
 1-ENGINEER OF RECORD TO REVIEW ALL TRUSS
 DRAWINGS PRIOR TO SUBMITTAL TO THIS
 OFFICE.
 2-ENGINEERED TRUSSES: REVISE MEAN ROOF
 HEIGHT.THIS IS A TWO STORY BUILDING.
 REMAINDER THERE IS ONLY ONE MEAN ROOF
 HEIGHT FOR ENTIRE BUILDING.
 3-PROVIDE COMPLETE DETAIL AND SPECS FOR
 LEDGER TO RECEIVE ROOF TRUSSES AT
 FRONT PORCH. SEC 104.2.2 CITY AMENDMEN
 4-PROVIDE COMPLETE SECTIONS/DETAILS FOR
 TWO STORY WALL SECTIONS. SPECIFY ALL
 CONNECTORS. SHEARWALLS. TRANSITION
 FROM FIRST FLOOR TO SECOND FLOOR. NOTE
 THAT THERE ARE TWO CONDITIONS: ONE
 WHEN EXTERIOR WALL IS PERPENDICULAR TO
 2ND FLOOR FRAMING AND ONE WHEN IT'S
 PARALLEL.
 5-CHECK/REVISE IF ALL HURRICANE ANCHORS
 SPECIFIED WILL BE ABLE TO RESIST THE
 HORIZONTAL LOADS SPECIFIED BY THE
 ENGINEERED TRUSSES.
 6-CLARIFY NOTE #1 ON ENGINEERED TRUSSES.
 FOR EXAMPLE, TRUSS JO5 AT FRONT PORCH
 SAYS IF PORCHES EXIST, THERE ARE NOT
 EXPOSED TO WIND. WHY?
 WHAT DOES DOL STANDS FOR?
 REVISE DESIGN CRITERIA DATA ON TRUSS
 LAYOUT. IT DOESN'T MATCH DESIGN
 CRITERIA SHOWN ON ENGINEERED TRUSSES.
 7-PROVIDE A COMPLETE DETAIL FOR ALUMINUM
 CEILINGS AT PORCH.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 1999-04-08 Cont ID  
Sent By jgomez Date 1999-04-08 Time 18:22 Rev Time 0.00
Received By jgomez Date   Time   Sent To O
Notes
2001-01-08 00:00:00APPROVED WITH PROVISO