Plan Review Details - Permit 98100735
Plan Review Stops For Permit 98100735
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 1999-01-05 Cont ID  
Sent By tlarge Date 1999-08-25 Time 10:13 Rev Time 1.00
Received By hpiskura Date 1999-01-05 Time 10:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 1998-11-06 Cont ID  
Sent By jleahy Date 1998-11-06 Time 14:45 Rev Time 1.30
Received By jleahy Date 1998-11-06 Time 14:45 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 1999-02-19 Cont ID  
Sent By hpiskura Date 1999-01-05 Time 10:14 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 1998-11-02 Cont ID  
Sent By hpiskura Date 1998-11-16 Time 16:14 Rev Time 0.00
Received By hpiskura Date 1998-11-16 Time 16:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 1999-08-25 Cont ID  
Sent By tlarge Date 1999-08-25 Time 10:05 Rev Time 0.65
Received By tlarge Date 1999-08-25 Time 10:05 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 1999-08-25 Cont ID  
Sent By tlarge Date 1999-08-05 Time 11:56 Rev Time 0.75
Received By tlarge Date 1999-08-05 Time 11:56 Sent To  
Notes
2001-01-08 00:00:00SANITARY AND WATER RISER SHALL CORRELATE
 W/FLOOR PLAN.SPC 104.2.1.
  
 FIXTURES DISCHARGING DOWNSTREAM OF WATER
 CLOSETS SHALL BE VENTED PER SPC SEC.
 913.2.
  
 WASHING MACHINES SHALL BE TRAPPED PER
 SPC 1001.2.
  
 MIN.SIZE OF U/G DRAINAGE SHALL BE 2" PER
 SPC SEC.714.4.
  
 MAIN VENT REQUIRED IN DRAINAGE SYSTEM
 PER SPC SEC.904.3.
  
 INDICATE SLOPE OF PIPE FOR SANITARY
 SYSTEM ON PLANS.COMPLY W/SPC SEC.714.1,
 714.2.
  
 HEAT TRAPS ARE REQ'D. ON THE WATER
 HEATER PER FLA.ENERGY CODE SEC.
 612.1ABC.2.2.
  
 SUBMIT SYSTEM LISTING NUMBER FOR FIRE
 RESISTANCE INTEGRITY OF PIPE PENETRATION
 THROUGH RATED WALLS.COMPLY W/SBC.SEC.
 104.2.4.
  
 SANITARY ISOMETRIC SHOWS DRY VENTS.
 CLARIFY.SPC.104.2.1.

Review Stop P PLUMBING
Rev No 2 Status P Date 1999-08-25 Cont ID  
Sent By pschmitz Date 1999-07-24 Time 11:41 Rev Time 0.75
Received By tlarge Date   Time   Sent To  
Notes
2001-01-08 00:00:00UNSAT:RISER FOR DWV, WATER PIPE.
 (1) PIPE SIZES FOR DWV.
 (2) DRAWINGS TO MATCH LAY-OUT.
 )3)WATER RISER TO SHOW HOT/COLD WITH
 LOCATION OF WTR HTR FOR LAUNDRY.

Review Stop P PLUMBING
Rev No 1 Status P Date 1998-10-27 Cont ID  
Sent By gjoyce Date 1998-10-16 Time 12:06 Rev Time 0.75
Received By pschmitz Date 1998-10-27 Time 16:05 Sent To  
Notes
2001-01-08 00:00:00PLUMBER TO FURNISH ISOMETRIC AT TIME OF
 PERMIT.

Review Stop Z ZONING
Rev No 2 Status P Date 1999-12-15 Cont ID  
Sent By gjoyce Date 1999-12-15 Time 15:28 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 1998-10-16 Cont ID  
Sent By gjoyce Date 1998-10-16 Time 12:06 Rev Time  
Received By gjoyce Date   Time   Sent To P
Notes
***NONE***