Plan Review Stops For Permit 23070239 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-07-14 |
Time |
12:25 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-07-14 |
Time |
12:25 |
Sent To |
|
|
Notes |
2023-07-14 12:25:35 | REMODEL TO BUILDING AND ALL 8 UNITS |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2023-07-28 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-28 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-28 |
Time |
12:51 |
Sent To |
|
|
Notes |
2023-07-28 12:52:35 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 23070239 | | | | REVIEWED: 7.28.2023 | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC BUILDING | | FBC EXISTING BUILDING | | | | COMMENTS: | | | | ASBESTOS PLAN REVIEW: FAILED | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | QUALIFIER, ON CONTRACTOR???S LETTERHEAD, STATING: | | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | ES/ENVIRONMENTAL-HEALTH/AIR- | | QUALITY/ASBESTOS-DEMOLITION-RENOVATION.HTML | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | HESITATE TO CONTACT ME | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | | | NOTES: | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-07-28 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-28 |
Time |
13:02 |
Rev Time |
|
Received By |
lbond |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2023-07-28 13:03:59 | | | | | SEE FLORIDA STATUE | | 481.229 UNDER SIGNATURE REVIEW | | | | PLEASE COMPLY AND RESUBMIT, | | | | ANY QUESTIONS OR CONCERNS: | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-07-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-07-14 |
Time |
15:06 |
Sent To |
|
|
Notes |
2023-07-14 15:08:21 | FIRE PROVISO: | | | | ENSURE SMOKE ALARMS ARE EXISTING OR INSTALLED NEW & | | INTERCONNECTED PER NFPA 101 CH 31, EXISTING APARTMENT | | BUILDING. | | | | ENSURE ABC FIRE EXTINGUISHERS PER NFPA 10 ARE INSTALLED | | IN EACH UNIT OR AT 75' APART ON THE EXTERIOR | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
amcgrego |
Date |
2023-07-11 |
Time |
13:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2023-07-21 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-07-21 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-07-21 |
Time |
11:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-07-27 |
|
|
Cont ID |
|
Sent By |
dantoine |
Date |
2023-07-27 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
dantoine |
Date |
2023-07-27 |
Time |
15:19 |
Sent To |
|
|
Notes |
2023-07-28 13:01:42 | FLORIDA STATUTES | | 481.229 | | | | WORK ON COMMERCIAL PROPERTY EXCEEDING $25,000 IN VALUE | | MUST INVOLVE FLORIDA LICENSED ARCHITECT OR ENGINEER. | | RESUBMIT PLAN DIGITALLY SIGNED AND SEALED | | | | ANY QUESTIONS OR CONCERNED: | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | | 2023-07-27 15:58:59 | 107.2.1 FBC [AMENDED] SHEETS UPLOADED INTO DRAWINGS | | FOLDER ARE NOT DIGITALLY SIGNED. | | - PLEASE RE-LOAD SHEETS WITH DIGITAL SIGNATURE. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
cibaven |
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|