|
 |
 |
 |
 |
 |
Plan Review Details - Permit 23061574
Plan Review Stops For Permit 23061574 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2023-07-26 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-26 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-26 |
Time |
11:59 |
Sent To |
|
|
Notes |
2023-07-26 12:00:59 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 23061574 | | | | REVIEWED:7.26.2023 | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC BUILDING | | FBC EXISTING BUILDING | | | | COMMENTS: | | | | ASBESTOS PLAN REVIEW: FAILED | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | QUALIFIER, ON CONTRACTOR???S LETTERHEAD, STATING: | | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | ES/ENVIRONMENTAL-HEALTH/AIR- | | QUALITY/ASBESTOS-DEMOLITION-RENOVATION.HTML | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | HESITATE TO CONTACT ME | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | | | NOTES: | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2023-07-26 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-26 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-26 |
Time |
12:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-07-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-07-27 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-07-27 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2023-07-17 |
|
|
Cont ID |
|
Sent By |
clfranci |
Date |
2023-07-17 |
Time |
|
Rev Time |
0.00 |
Received By |
clfranci |
Date |
2023-07-17 |
Time |
|
Sent To |
|
|
Notes |
2023-07-17 14:14:55 | THIS PLAN WAS REVIEWED AND FAILED BY CAITLIN L FRANCIS, | | FIRE INVESTIGATOR, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE INDICATIONS OF FLOORING RENOVATION ON THE | | APPLICATION BUT NO SPECIFICATIONS SHEETS THAT INDICATE | | MEETING THE REQUIREMENTS PER NFPA' | | | | PER NFPA 101, CH 10 | | SECTION 10.2. | | | | 10.2.7* INTERIOR FLOOR FINISH TESTING AND | | CLASSIFICATION. | | 10.2.7.1* CARPET AND CARPET LIKE INTERIOR FLOOR | | FINISHES SHALL | | COMPLY WITH ASTM D 2859, STANDARD TEST METHOD FOR | | IGNITION | | CHARACTERISTICS OF FINISHED TEXTILE FLOOR COVERING | | MATERIALS. | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | 10.2.2.2 | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | HAVE A | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | 10.2.7.4 INTERIOR FLOOR FINISHES SHALL BE GROUPED IN | | THE CLASSES SPECIFIED | | IN 10.2.7.4.1 AND 10.2.7.4.2 IN ACCORDANCE WITH THE | | CRITICAL RADIANT FLUX | | REQUIREMENTS. | | 10.2.7.4.1 CLASS I INTERIOR FLOOR FINISH. CLASS I | | INTERIOR FLOOR FINISH | | SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN | | 0.45 W/CM2, AS DETERMINED | | BY THE TEST DESCRIBED IN 10.2.7.3. | | 10.2.7.4.2 CLASS II INTERIOR FLOOR FINISH. CLASS II | | INTERIOR FLOOR FINISH | | SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN | | 0.22 W/CM2, BUT LESS | | THAN 0.45 W/CM2, AS DETERMINED BY THE TEST DESCRIBED IN | | 10.2.7.3. | | | | PLEASE REVIEW AND PROVIDE SPEC SHEETS. | | | | | | | | CAITLIN L FRANCIS | | FIRE INVESTIGATOR | | WEST PALM BEACH FIRE RESCUE | | 561.804.4728 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-07-27 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-07-27 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-07-11 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-07-24 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-07-24 |
Time |
13:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2023-07-18 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-07-18 |
Time |
06:17 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-07-18 |
Time |
06:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-07-26 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-26 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-26 |
Time |
12:02 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |