Plan Review Details - Permit 23061380
Plan Review Stops For Permit 23061380
Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2023-07-07 Time   Rev Time 0.00
Received By lmarchan Date 2023-06-29 Time 12:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-07-07 Cont ID  
Sent By ccole Date 2023-07-07 Time 12:31 Rev Time 0.00
Received By ccole Date 2023-07-07 Time 12:04 Sent To  
Notes
2023-07-07 12:32:061ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23061380
 7/7/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FAIR HOUSING DESIGN ACT MANUAL- FHDA
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) FAIR HOUSING ACT COMPLIANCE: THE FLAGLER POINTE
 CONDOMINIUMS ARE SUBJECT TO COMPLIANCE WITH FAIR
 HOUSING ACCESSIBILITY GUIDELINES WHICH CAME INTO EFFECT
 FOR MULTIFAMILY HOUSING BUILT FOR FIRST OCCUPANCY AFTER
 MARCH 13, 1991. THE SUBMITTED PLAN SHOWING BATHTUB TO
 SHOWER CONVERSIONS SHOWER MUST BE MODIFIED IN
 ACCORDANCE WITH COMMENTS #2 & #3 BELOW. PLEASE NOTE: AS
 AN ALTERNATIVE TO MEETING THE GUIDELINES FOR THE BATH
 ALTERATIONS, THE OWNER AND DESIGNER OF RECORD FOR THE
 PROPOSED PROJECT MAY PROVIDE A SIGNED AND NOTARIZED
 AFFIDAVIT WHICH WOULD INDICATE ACKNOWLEDGEMENT THAT THE
 PROPOSED DESIGN DOES NOT MEET THE REQUIREMENTS OF THE
 FAIR HOUSING ACCESSIBILITY GUIDELINES, BUT WILL ALSO
 REQUIRE THE OWNER TO AGREE TO REVERT THE UNIT BACK TO
 COMPLIANCE AT TIME OF SALE IF REQUESTED BY THE BUYER.
 IF THIS OPTION IS CHOSEN, PLEASE SEND AN EMAIL TO
 [email protected] AND I WILL SEND A COPY OF THE FAIR
 HOUSING AFFIDAVIT.
  
 2) REFER TO PAGES 7.56- 7.59 OF THE FHDA MANUAL AND
 PROVIDE A DRAWING FOR THE BATHROOM THAT SHOWS THE
 DIMENSIONS OF THE SHOWER AND THE REQUIRED 30X48-INCH
 CLEAR FLOOR SPACE DIAGRAM POSITIONED PARALLEL TO THE
 SHOWER AND FLUSH WITH THE CONTROL WALL. PLEASE NOTE
 THAT NO OTHER FIXTURES SHALL OBSTRUCT THE CLEAR FLOOR
 SPACE REQUIRED FOR THE SHOWER WITH THE EXCEPTION OF A
 LAVATORY WHICH MAY OVERLAP BY 6-INCHES. THE LAVATORY
 SHALL BE A WALL HUNG WITH KNEE AND TOE CLEARANCES OR
 HAVE A REMOVABLE CABINET.
  
 3) PROVIDE AN ELEVATION DETAIL FOR THE SHOWER THAT
 SHOWS THE LOCATIONS OF REQUIRED GRAB BAR REINFORCEMENTS
 IN ACCORDANCE WITH PAGE 6.13.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-07-07 Cont ID  
Sent By ccole Date 2023-07-07 Time 12:32 Rev Time 0.00
Received By ccole Date 2023-07-07 Time 12:04 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved