Plan Review Details - Permit 23061338
Plan Review Stops For Permit 23061338 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-07-12 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-07-12 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2023-07-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-07-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-07-06 |
Time |
14:42 |
Sent To |
|
|
Notes |
2023-07-06 15:01:25 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE SPEC SHEET STATES: | | | | INSTALLATION GUIDELINES | | | | 1) EXHAUST IS AIMED AWAY FROM OR PARALLEL TO THE | | STRUCTURE. | | | | 2) EXHAUST IS NOT DIRECTED AT PLAY AREAS, PATIOS OR | | OTHER AREAS WHERE PEOPLE CONGREGATE. | | | | 3) THE NEAREST WINDOW, VENT, DOOR OR SIMILAR STRUCTURE | | OPENING IS AT LEAST 5 FEET FROM THE EXHAUST END OF THE | | GENERATOR. | | | | 4) GENERATOR SET MUST BE INSTALLED A MINIMUM OF 18 | | INCHES FROM STRUCTURE PER NFPA 37, HOWEVER, ACTUAL | | DISTANCE MAY DIFFER BASED ON STATE AND LOCAL CODES. | | | | 5) WINDOWS & DOORS ON ADJACENT WALLS ARE CLOSED. | | | | 6) FURNACE AND OTHER SIMILAR INTAKES ARE AT LEAST 10 | | FEET FROM EXHAUST END OF GENERATOR. | | | | | | THE FLOOR PLAN DOES NOT INDICATE DETAILS IN COMPLIANCE | | WITH THE INSTALLATION GUIDELINES. | | | | PLEASE REVIEW AND PROVIDE THE APPLICABLE SPECIFIC | | DETAILS/DIMENSIONS. | | | | | | | | 2) THERE ARE INDICATIONS OF A NG LINE HOWEVER, THERE | | ARE NO DETAILS PER NFPA 54, INCLUDING SERVICE LINE | | LEENGTH, DEPTH OF COVERAGE, NEW GAS METER DIMENSION | | FROM AN ELECTICAL SPARK SOURCE, ETC. | | | | PLEASE REVIEW, ENSURE COMPLIANCE AND PROVIDE ALL | | APPLICABLE AND REQUIRED DIMENSIONS. | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-07-03 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-07-03 |
Time |
06:11 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-07-03 |
Time |
06:10 |
Sent To |
|
|
Notes |
2023-07-03 06:15:02 | 1ST GAS REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMENDS 107.3.5.1.5 - PLEASE SUBMIT THE GAS | | DOCUMENTS. INCLUDE: | | A) A SITE PLAN SHOWING THE LOCATION OF THE GENERATOR. | | INCLUDE DETAILS THAT WOULD INDICATE SETBACKS FROM | | PROPERTY LINES AND DISTANCES FROM STRUCTURE OPENINGS | | AND AIR INTAKES. | | B) PLEASE SUBMIT A GAS RISER DIAGRAM THAT INCLUDES ANY | | OF THE FOLLOWING APPLICABLE ITEMS. LOCATION OF | | SHUT-OFFS, THE PIPING MATERIAL, GAS PIPE SIZING METHOD | | AND BTU LOADS, VENTING OF APPLIANCES, COMBUSTION AIR | | CALCULATIONS, APPLIANCE SCHEDULE, THE TYPE OF GAS | | PROPOSED, METER LOCATION, AND THE EXISTING GAS SYSTEM | | (LABELING EXISTING AND NEW FOR CLARITY). | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
amcgrego |
Date |
2023-06-30 |
Time |
12:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2023-07-20 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-07-20 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-07-20 |
Time |
12:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-07-03 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-07-03 |
Time |
06:10 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-07-03 |
Time |
06:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-07-17 |
|
|
Cont ID |
|
Sent By |
ecolon |
Date |
2023-07-17 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
ecolon |
Date |
2023-07-17 |
Time |
16:40 |
Sent To |
|
|
Notes |
2023-07-17 16:44:46 | SUBMIT A SITE PLAN ILLUSTRATING THE LOCATION OF THE | | PROPOSED GENERATOR. PLEASE INCLUDE DETAILS SUCH AS | | SETBACKS FROM THE PROPERTY LINE. AS PER SEC. 94-305 (4) | | - MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR | | FEET INTO A SETBACK. | | | | | | **** REVIEWED BY **** | | | | ERIK COLON | | 5618221398 | | [email protected] |
|
|
|