Plan Review Details - Permit 23061099
Plan Review Stops For Permit 23061099
Review Stop AFFIDAVIT PRIVATE PROVIDER AFFIDAVIT
Rev No 1 Status P Date 2023-07-10 Cont ID  
Sent By jgomez Date 2023-07-10 Time 13:13 Rev Time 0.00
Received By jgomez Date 2023-07-10 Time 12:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-08-02 Cont ID  
Sent By jgomez Date 2023-08-02 Time 17:44 Rev Time 0.00
Received By jgomez Date 2023-08-02 Time 11:22 Sent To  
Notes
2023-08-02 17:45:04RESIDENTIAL(R3) SOLAR PANELS BUILDING AUDIT.
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23061099
 800 44TH ST
  
 1- THE ROOF PRESSURES SPECIFIED ON SHEET S-1 ARE TOO
 LOW FOR A BUILDING LOCATED IN EXPOSURE C.
 SEC. R301.2.1 FBC-RESIDENTIAL.
 NOTE: COORDINATE REVISED PRESSURES WITH CROSSRAIL
 SYSTEM STRUCTURAL EVALUATION ON SHEETS S-11 AND S-12.
  
 2- ROOF DIMENSION "A" NEEDS TO BE 4" NOT 3" AS REQUIRED
 BY NOTE "A" ON FIGURE R301.2(7) FBC-RESIDENTIAL. REVISE
 AS REQUIRED.
  
 3- SHEET S-2 SHOWS A "TYPICAL SHINGLE ROOF LAYOUT".
 ENGINEER OF RECORD NEEDS TO SHOW ROOF PLAN SHOWING
 SPECIFIC LOCATION OF MODULES AND SPECIFIC ANCHORING
 POINTS.
 SEC. R301.2.1 FBC-RESIDENTIAL. SEC. 107.2.1.2 CITY
 AMENDMENTS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-07-21 Cont ID  
Sent By jleahy Date 2023-07-21 Time 18:00 Rev Time 0.00
Received By jleahy Date 2023-07-21 Time 17:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By shill Date 2023-07-06 Time 08:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-11 Cont ID  
Sent By shill Date 2023-07-06 Time 08:31 Rev Time 0.00
Received By shill Date 2023-06-27 Time 08:43 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-07-21 Cont ID  
Sent By jleahy Date 2023-07-21 Time 18:00 Rev Time 0.00
Received By jleahy Date 2023-07-21 Time 18:00 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-07-06 Cont ID  
Sent By vbroglia Date 2023-07-06 Time 09:16 Rev Time 0.00
Received By vbroglia Date 2023-07-06 Time 09:16 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved