Plan Review Stops For Permit 23060584 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-24 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-24 |
Time |
11:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2023-06-26 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-26 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-26 |
Time |
08:31 |
Sent To |
|
|
Notes |
2023-06-26 08:32:01 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 23060584 | | | | REVIEWED: 6.26.2023 | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC BUILDING | | FBC EXISTING BUILDING | | | | COMMENTS: | | | | ASBESTOS PLAN REVIEW: FAILED | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING: | | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | ES/ENVIRONMENTAL-HEALTH/AIR- | | QUALITY/ASBESTOS-DEMOLITION-RENOVATION.HTML | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | HESITATE TO CONTACT ME | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | | | NOTES: | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-24 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-24 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-06-26 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-26 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-26 |
Time |
08:39 |
Sent To |
|
|
Notes |
2023-06-26 08:44:53 | PERMIT- 23060584 | | 6.26.2023 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | FHDA- FAIR HOUSING DESIGN ACT MANUAL | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1. CLARIFY IF THE EXISTING TUB DRAIN WILL BE RE-USED OR | | IF A NEW DRAIN WILL BE INSTALLED IN THE CENTER OF THE | | SHOWER. PLEASE NOTE THE FOLLOWING FOR NEW DRAIN | | INSTALLATIONS: | | RELOCATING THE SHOWER DRAIN OUTLET MAY REQUIRE THE | | FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING | | STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A | | NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET- | | SECTION 107.2.1 WPB. | | NEW DRAINPIPE PENETRATIONS OF THE EXISTING SLAB WILL | | REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE AROUND | | THE PIPING. PROVIDE A UL TESTED AND APPROVED | | FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION 315.1 | | FBC P AND SECTION 714.4.1.2 FBC B. | | | | 2. [FBC 1207.3] STRUCTURE-BORNE SOUND. FLOOR/CEILING | | ASSEMBLIES | | BETWEEN DWELLING UNITS AND SLEEPING UNITS OR BETWEEN A | | DWELLING | | UNIT OR SLEEPING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN | | THE STRUCTURE SHALL HAVE AN IMPACT INSULATION CLASS | | RATING OF | | NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED, | | WHEN TESTED | | IN ACCORDANCE WITH ASTM E492. | | | | 3. [FBC 603.1] ALLOWABLE MATERIALS IN NON-COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. | | | | PROVIDE PROPOSED NEW FLOORING NOA OF FBC PRODUCT | | APPROVAL AND SPECS SAME FOR UNDERLAYMENT. FLAME SPREAD, | | ACCOUSTIC PROPERTY AND SOUND TEST DOCUMENTATION | | REQUIRED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
Sent By |
rperdomo |
Date |
2023-06-26 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
rperdomo |
Date |
2023-06-26 |
Time |
16:06 |
Sent To |
|
|
Notes |
2023-06-26 16:34:04 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | ELECTRICAL REVIEW STATUS: APPROVED, SEE COMMENTS BELOW | | | | 1. SEPARATE PERMIT IS REQUIRED FOR LOW VOLTAGE WIRING. | | | | END OF COMMENTS | | | | RUBEN P. PERDOMO, P.E. | | ELECTRICAL PLANS EXAMINER/ INSPECTOR | | 561-805-6738 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2023-07-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-07-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-07-24 |
Time |
10:45 |
Sent To |
|
|
Notes |
2023-07-24 10:51:59 | FIRE PREVENTION COMMENTS: | | | | PROTECT FIRE ALARM DEVICES AND EQUIPMENT. | | | | DO NOT PAINT OVER FIRE ALARM DEVICES/EQUIPMENT. | | | | THE FA SYSTEM SHALL BE MAINTAINED THROUGHOUT DEMO AND | | CONSTRUCTION. | | | | ANY WORK/DAMAGE ON THE FA SYSTEM SHALL BE | | CORRECTED/REPAIRED UNDER SEPARATE PERMIT AND SHOP | | DRAWING BY FA CONTRACTORS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-06-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-06-21 |
Time |
15:54 |
Sent To |
|
|
Notes |
2023-06-21 16:18:46 | FIRE PREVENTION COMMENTS: | | | | PROTECT FIRE ALARM DEVICES AND EQUIPMENT. | | | | DO NOT PAINT OVER FIRE ALARM DEVICES/EQUIPMENT. | | | | THE FA SYSTEM SHALL BE MAINTAINED THROUGHOUT DEMO AND | | CONSTRUCTION. | | | | ANY WORK/DAMAGE ON THE FA SYSTEM SHALL BE | | CORRECTED/REPAIRED UNDER SEPARATE PERMIT AND SHOP | | DRAWING BY FA CONTRACTORS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-07-21 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-07-10 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-07-10 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-16 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-07-10 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-07-10 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-07-10 |
Time |
10:03 |
Sent To |
|
|
Notes |
2023-07-10 11:02:20 | PLAN DENIED | | 1) SHOW BATHROOM EXHAUST ON THE MEP. PLAN. | | SHOW TERMINATION OF THE EXHAUST AND MATERIAL USED | | FOR EXHAUST PIPE. SECTION 403.3.2.3 BATHROOM EXHAUST | | 2020 FBC (M). | | 2) PLEASE PROVIDE MORE INFORMATION ON KITCHEN EXHAUST | | HOOD | | REFER TO SECTION C403.2.4.3. SHUT OFF DAMPERS 2020 | | FLORIDA ENERGY CODE. | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-07-24 |
Time |
06:06 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-07-24 |
Time |
06:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-06-21 |
Time |
06:17 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-06-21 |
Time |
06:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-24 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-24 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-26 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-26 |
Time |
08:30 |
Sent To |
|
|
Notes |
|
|