Plan Review Stops For Permit 23060358 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2023-06-20 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-06-20 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-06-20 |
Time |
09:43 |
Sent To |
|
|
Notes |
2023-06-20 09:43:45 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2023-06-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-29 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-29 |
Time |
15:09 |
Sent To |
|
|
Notes |
2023-06-29 15:10:15 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-06-29 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-29 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-29 |
Time |
11:18 |
Sent To |
|
|
Notes |
2023-06-29 15:11:39 | REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE AN EXISTING FLOOR PLAN. FBC WPB 107.2 | | | | 2) PLEASE WRITE THE SCOPE OF WORK ON THE DRAWINGS - FBC | | WPB 107.2 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-06-28 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-06-28 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-06-26 |
Time |
13:18 |
Sent To |
|
|
Notes |
2023-06-28 17:07:01 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PLAN E-1 CALLS FOR NEW MAIN SWITCH GEAR AND SUBFEEDERS | | IS THIS CORRECT? IS THERE A PERMIT FOR THAT ? | | | | PLAN ON E-1 DOES NOT MATCH PLANS ON PAGES ID-101.1 AND | | ID-102.1 DIFFERENT LAYOUT OF KITCHEN. | | | | PLEASE IDENTIFY WHAT IS BEING DONE IN THE UNIT ON THE | | PLAN. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2023-06-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-06-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-06-21 |
Time |
13:14 |
Sent To |
|
|
Notes |
2023-06-21 13:15:24 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) THERE ARE SUBMITTED PLANS; HOWEVER, THERE ARE NO | | DETAILS ON THESE PALNS TO REVIEW FOR LIFE SAFETY CODE | | COMPLIANCE. | | | | THERE IS NO SCOPE OF WORK NOR ANY DETAILED PLAN SHEETS | | ON WHAT IS EXISTING OR WHAT IS NEW. | | | | PER NFPA 1 | | | | 1.7.12 PLANS AND SPECIFICATIONS. | | | | 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE | | PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH | | APPLICABLE CODES AND STANDARDS | | | | 1.7.12.6 PLANS SHALL BE SUBMITTED TO THE AHJ PRIOR TO | | THE ALTERATION OF THE MEANS OF EGRESS OR FIRE | | PROTECTION SYSTEMS OF ANY EXISTING BUILDING. | | | | PLEASE REVIEW AND PROVIDE THE REQUIRED PLAN SHEETS AND | | DETAILS TO CONDUCT A THOROUGH LIFE SAFETY REVIEW OF THE | | PROPOSED WORK. | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-07-05 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-07-05 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-07-05 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-07-05 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-07-05 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-07-05 |
Time |
13:30 |
Sent To |
|
|
Notes |
2023-07-05 13:31:00 | MECHANICAL PLAN NEEDS SUPPLY DUCT SIZES FBC 107 | | | | | | CHRIS MONTELLO | | 561-805-6733 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-06-22 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-06-22 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-06-22 |
Time |
14:04 |
Sent To |
|
|
Notes |
2023-06-22 14:04:21 | 1ST PLUMBING REVIEW | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2020 FPC 406.2 - THE SANITARY ISOMETRIC SHOWS AN 1 | | 1/2" STANDPIPE TO THE WASHING MACHINE. A 2" IS | | REQUIRED. | | | | 2. WPB ORD. SEC. 90 - 126 - PLEASE SHOW A DETAIL THAT | | INCLUDE THE DISCHARGE LOCATION OF THE AC CONDENSATE | | DRAIN TO VERIFY IT DOES NOT GO INTO THE SANITARY. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-06-28 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-06-28 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-06-28 |
Time |
17:07 |
Sent To |
|
|
Notes |
2023-06-28 17:08:24 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PLAN E-1 DIGITAL SIGNATURE IS NOT VERIFIABLE WPB | | 107.2.1 |
|
|