Plan Review Details - Permit 23060307
Plan Review Stops For Permit 23060307 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2023-07-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-07-14 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-07-14 |
Time |
14:18 |
Sent To |
|
|
Notes |
2023-07-14 14:19:41 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE ADDRESS, PERMIT NUMBER AND ???ASBESTOS??? | | IN THE SUBJECT LINE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-07-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-07-14 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-07-14 |
Time |
14:18 |
Sent To |
|
|
Notes |
2023-07-14 15:48:29 | PLAN REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT PRODUCT FOR EXTERIOR STOREFRONTS AND DOORS. | | FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS FOR | | THOSE PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001 | | PER FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA | | NUMBERS INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM | | DESIGN PRESSURES FOR EACH OF THE DIFFERENT ROOFING | | MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL MULLIONS | | AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE DEFERRED IF | | REQUESTED AND LISTED ON THE PLANS, HOWEVER, THE | | DOCUMENTS MUST BE SUBMITTED AND APPROVED BY THE | | BUILDING DEPARTMENT BEFORE THEY CAN BE INSTALLED. ONLY | | ONE SET IS REQUIRED TO BE UPLOADED FOR ELECTRONICALLY | | SUBMITTED DOCUMENTS. | | | | 2) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW THE | | REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-07-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-07-07 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-07-07 |
Time |
07:56 |
Sent To |
|
|
Notes |
2023-07-07 15:20:29 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | OUTLETS IN THE KITCHEN AND WITHIN 6" OF THE SINKS TO BE | | GFCI PROTECTED | | | | POS 5,11 | | PANEL A-4,39,2,33,31,29,27,23,25 | | PANEL B-37,6,4,17,28,16,26 | | PANEL C-17 | | PANEL D-2,37,31,25,36,19,13,7,1 | | PANEL E-19,8,2,10,31,32,46 | | PANEL F-26, 24,22,27,29,14 | | PANEL G-6,10,12,14,8,41,2,37,5,13,3,9,23,6,35,14,41 | | | | 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | PERSONNEL. | | | | GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | PERSONNEL SHALL BE PROVIDED AS REQUIRED IN 210.8(A) | | THROUGH (E). THE GROUND-FAULT CIRCUIT INTERRUPTER SHALL | | BE INSTALLED IN A READILY ACCESSIBLE LOCATION. | | (B) OTHER THAN DWELLING UNITS. | | ALL SINGLE-PHASE RECEPTACLES RATED 150 VOLTS TO GROUND | | OR LESS, 50 AMPERES OR LESS AND THREE-PHASE RECEPTACLES | | RATED 150 VOLTS TO GROUND OR LESS, 100 AMPERES OR LESS | | INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE | | GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | PERSONNEL. | | | | (2) | | KITCHENS | | | | (5) | | SINKS ??? WHERE RECEPTACLES ARE INSTALLED WITHIN 1.8 M | | (6 FT) FROM THE TOP INSIDE EDGE OF THE BOWL OF THE SINK | | EXCEPTION NO. 1 TO (5): IN INDUSTRIAL LABORATORIES, | | RECEPTACLES USED TO SUPPLY EQUIPMENT WHERE REMOVAL OF | | POWER WOULD INTRODUCE A GREATER HAZARD SHALL BE | | PERMITTED TO BE INSTALLED WITHOUT GFCI PROTECTION. | | | | EXCEPTION NO. 2 TO (5): FOR RECEPTACLES LOCATED IN | | PATIENT BED LOCATIONS OF GENERAL CARE (CATEGORY 2) OR | | CRITICAL CARE (CATEGORY 1) SPACES OF HEALTH CARE | | FACILITIES OTHER THAN THOSE COVERED UNDER 210.8(B)(1), | | GFCI PROTECTION SHALL NOT BE REQUIRED. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2023-06-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-06-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-06-13 |
Time |
15:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-07-17 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-07-17 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-07-17 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2023-07-17 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2023-07-17 |
Time |
13:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-06-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-30 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-30 |
Time |
06:58 |
Sent To |
|
|
Notes |
2023-06-30 17:28:05 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 23060307 | | 6/30/23 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS P2.1 & P5.2: THE PLANS DO NOT APPEAR TO SHOW | | A MEANS OF POTABLE WATER SUPPLY TO THE FILTERED WATER | | SYSTEM- SEC. 608.4 FBC P. | | | | 2) SHEETS P1.1 & P5.1: THE PLANS SHOW NON-GREASE-LADEN | | WASTE FROM HAND SINKS (P-5) AND TRENCH RECEIVING | | DISCHARGES FROM ICE MACHINES (P-29A, P-29B, P-29C) | | DRAINING INTO THE GREASE WASTE LINE WHICH IS PROHIBITED | | PER SEC. 1003.3.1 FBC P. THE DRAINAGE FROM THE FIXTURES | | SHALL BE RE-ROUTED TO THE SANITARY. PLEASE CLARIFY IF | | THE TRENCH DRAINS ARE ALSO CONVEYING OTHER WASTE WATER | | THAT IS GREASE-LADEN. | | | | 3) D-201: THERE IS NO CORRELATING TEXT FOR NOTE #17 | | WHICH IS SHOWN IN THE EXISTING RESTROOMS- SEC. 107.2.1 | | WPB. | | | | 4) G-002, A-201: IT APPEARS NEW BATHROOM FIXTURES AND | | COMPARTMENTS ARE BEING INSTALLED. PLEASE PROVIDE | | ENLARGED FLOOR PLAN DRAWINGS AND DETAILS SHOWING | | ACCESSIBLE WATER CLOSET DIMENSIONS AND THE CLEAR FLOOR | | SPACE DIAGRAMS AND DIMENSIONS FOR THE WATER CLOSETS AND | | LAVATORIES- SECS. 604.3 & 606.2 FBC ACC. | | | | 5) G-002: THE WATER CLOSET CENTERLINE MEASUREMENT IS | | NOT SHOWN IN THE DETAIL- SEC. 604.2 FBC ACC. | | | | 6) G-002: SHOW THE HEIGHTS OF THE GRAB BARS MEASURED | | FROM THE FINISHED FLOORS TO THE TOPS OF THE GRIPPING | | SURFACES- SEC. 609.4 FBC ACC. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-07-14 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-07-14 |
Time |
14:18 |
Sent To |
|
|
Notes |
2023-06-30 07:24:11 | PLUMBING DIG/SIGS PASSED. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-06-22 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-06-22 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
|