Plan Review Details - Permit 23060201
Plan Review Stops For Permit 23060201 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2023-07-06 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-07-06 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-07-05 |
Time |
08:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-06-27 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-06-27 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-06-27 |
Time |
07:52 |
Sent To |
|
|
Notes |
2023-06-27 11:24:53 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL1654-R31 SYSTEM NO. W-193 DOES NOT MEET THE | | MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -108.17 | | FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM THAT | | MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR | | EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED | | ENGINEERED NAILING CALCULATIONS WITH AN APPROVED | | SYSTEM. PLEASE NOTE: PRODUCT APPROVAL FL1654-R31 WAS | | REVISED ON 06/20/2023 TO FL1654-R32. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2023-06-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-15 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-15 |
Time |
08:34 |
Sent To |
|
|
Notes |
2023-06-15 08:40:38 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE A PRODUCT APPROVAL FOR THE FLAT DECK | | - PRODUCT APPROVAL FOR THE FLAT DECK ROOFING = NEED TO | | CHOOSE A ROOFING SYSTEM IN THE PRODUCT APPROVAL THAT | | SHOWS THE REQUIRED WIND DESIGN PRESSURE PER FBC R TABLE | | R301.2(2) - PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED | | IN THE PRODUCT APPROVAL - IF NEEDED PLEASE PROVIDE | | ADDITIONAL ATTACHMENT DETAILS FROM AN ARCHITECT OR | | ENGINEER FOR THE ROOF ZONES 1, 2 AND 3 WHICH MAY | | REQUIRE A HIGHER WIND PRESSURE THEN THE CHOSEN ROOFING | | SYSTEM - SEE NOTES ON THE PRODUCT APPROVAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-06-12 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-06-12 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-06-12 |
Time |
07:55 |
Sent To |
|
|
Notes |
2023-06-12 09:10:01 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1 SUBMITTED ROOF DIAGRAM/SKETCH APPEARS | | TO INDICATE REROOFING LOW/FLAT SLOPE AREA (CRICKET); IF | | NOT INDICATE BY PLACING AN X IN LOW/FLAT SLOPE AREAS | | (CRICKET); IF TO RECEIVE NEW ROOFING PROVIDE A COMPLETE | | SET OF 2020 CODE VERSION PRODUCT APPROVALS/NOA'S FOR | | THE PROPOSED FLAT ROOF SYSTEM TO BE USED. INCLUDE COVER | | PAGE, EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS | | FOR SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | ENGINEERING. PLEASE NOTE ADDRESS IS LOCATED IN AN | | EXPOSURE C CATEGORY AREA. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-07-06 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-07-06 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-06-28 |
Time |
10:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-06-27 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-06-27 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-06-16 |
Time |
08:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-06-15 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2023-06-15 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2023-06-13 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-06-12 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2023-06-12 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2023-06-09 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |