Plan Review Details - Permit 23060101
Plan Review Stops For Permit 23060101
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-06-20 Cont ID  
Sent By cpuell Date 2023-06-20 Time 10:10 Rev Time 0.00
Received By cpuell Date 2023-06-20 Time 10:10 Sent To  
Notes
2023-06-20 10:10:58ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-07-17 Cont ID  
Sent By rmcphers Date 2023-07-17 Time 11:44 Rev Time 0.00
Received By rmcphers Date 2023-07-17 Time 11:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-05 Cont ID  
Sent By rmcphers Date 2023-07-05 Time 16:31 Rev Time 0.00
Received By rmcphers Date 2023-07-05 Time 14:55 Sent To  
Notes
2023-07-05 16:22:34SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE STORM WATER FLOW AWAY FROM THE
 BUILDING AND AWAY FROM THE ADJACENT PROPERTIES ON THE
 SITE PLAN OR PROVIDE A SEPARATE STORM WATER DRAINAGE
 PLAN - FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION
 DOCUMENTS SUBMITTED WITH THE APPLICATION FOR PERMIT
 SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE
 THE SIZE AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS
 APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN
 FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE
 WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE
 SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED
 WATER RETAINING SWALES)
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-06-26 Cont ID  
Sent By rperdomo Date 2023-06-26 Time 12:14 Rev Time 0.00
Received By rperdomo Date 2023-06-26 Time 11:52 Sent To  
Notes
2023-06-26 12:18:31FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: APPROVED, SEE COMMENTS BELOW
  
 1. PLEASE SEE NEC 2017 TABLE 250.102(C)(1) FOR GROUNDED
 ELECTRICAL CONDUCTOR.
 2. SEPARATE PERMIT REQUIRED FOR LOW VOLTAGE WIRING.
  
 END OF COMMENTS
  
 RUBEN P. PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER/ INSPECTOR
 561-805-6738
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-14 Time 09:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-06 Cont ID  
Sent By ecolon Date 2023-07-06 Time 12:33 Rev Time 0.00
Received By aoliver Date 2023-06-15 Time 11:56 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-07-05 Cont ID  
Sent By rmcphers Date 2023-07-05 Time 16:31 Rev Time 0.00
Received By rmcphers Date 2023-07-05 Time 16:31 Sent To  
Notes
2023-07-05 16:33:27PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-05 Cont ID  
Sent By cmontell Date 2023-07-05 Time 12:56 Rev Time 0.00
Received By cmontell Date 2023-07-05 Time 12:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-06-20 Cont ID  
Sent By rwbrown Date 2023-06-20 Time 15:59 Rev Time 0.00
Received By rwbrown Date 2023-06-20 Time 15:58 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2023-07-05 Cont ID  
Sent By rmcphers Date 2023-07-05 Time 16:33 Rev Time 0.00
Received By rmcphers Date 2023-07-05 Time 16:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-07-05 Cont ID  
Sent By rmcphers Date 2023-07-05 Time 16:35 Rev Time 0.00
Received By rmcphers Date 2023-07-05 Time 16:35 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-07-06 Cont ID  
Sent By ecolon Date 2023-07-06 Time 12:32 Rev Time 0.00
Received By ecolon Date 2023-07-06 Time 12:27 Sent To  
Notes
2023-07-06 12:32:46SEPARATE PERMIT REQUIRED FOR: FENCE/WALL, DRIVEWAY,
 MECHANICAL/AC, LANDSCAPE. PROPOSED GUEST HOUSE NOT
 PERMITTED IN SF7


Account Summary | Usage Policy | Privacy Policy