Plan Review Stops For Permit 23060023 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
2023-06-08 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-06-08 |
Time |
07:03 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-06-08 |
Time |
07:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
AFFIDAVIT |
PRIVATE PROVIDER AFFIDAVIT |
Rev No |
1 |
Status |
P |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-06-16 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-06-16 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-07-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-07-18 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-07-18 |
Time |
14:26 |
Sent To |
|
|
Notes |
2023-07-18 14:29:04 | PRIVATE PROVIDER AUDIT | | | | AUDIT STATUS FAILED | | | | 1) THE EXPOSURE CATEGORY FOR THIS PROJECT IS C. PLEASE | | REVISE THE DRAWINGS. FBC-R301.2.1.4.3 | | | | 2) SUBMIT A STRUCTURAL ANALYSIS OF THE EXISTING ROOF | | STRUCTURE SHOWING THAT IT IS CAPABLE OF SUPPORTING ALL | | LOADS TRANSFERRED TO IT BY THE PHOTOVOLTAIC SYSTEM. | | FBC-R324.4.1 STRUCTURAL REQUIREMENTS. ROOFTOP-MOUNTED | | PHOTOVOLTAIC PANEL SYSTEMS SHALL BE DESIGNED TO | | STRUCTURALLY SUPPORT THE SYSTEM AND WITHSTAND | | APPLICABLE GRAVITY LOADS IN ACCORDANCE WITH CHAPTER 3. | | THE ROOF ON WHICH THESE SYSTEMS ARE INSTALLED SHALL BE | | DESIGNED AND CONSTRUCTED TO SUPPORT THE LOADS IMPOSED | | BY SUCH SYSTEMS IN ACCORDANCE WITH CHAPTER 8. | | | | FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-06-28 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-06-28 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-06-28 |
Time |
08:56 |
Sent To |
|
|
Notes |
2023-06-28 08:57:21 | AUDIT OF ELECTRICAL PLANS PASSED. MP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-07-20 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-07-20 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-06-15 |
Time |
07:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2023-06-15 |
Time |
|
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2023-06-07 |
Time |
13:14 |
Sent To |
|
|
Notes |
2023-06-08 07:02:48 | B & E REMOVED |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2023-07-19 |
|
|
Cont ID |
|
Sent By |
jbaker |
Date |
2023-07-19 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
jbaker |
Date |
2023-07-19 |
Time |
09:08 |
Sent To |
|
|
Notes |
2023-07-19 09:10:56 | [email protected] | | | | IN THE BOX AT THE BOTTOM OF PAGE THE CERTIFICATE OF | | INSURANCE DOES NOT CONTAIN THE STATUTORY LANGUAGE FOUND | | IN 553.791 (4)(B) THAT A CERTIFICATE OF INSURANCE | | DEMONSTRATES PROFESSIONAL LIABILITY INSURANCE COVERAGE | | IS IN PLACE FOR THE PRIVATE PROVIDER???S FIRM, THE | | PRIVATE PROVIDER, AND ANY DULY AUTHORIZED | | REPRESENTATIVE IN THE AMOUNTS REQUIRED BY 553.791(17) |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-06-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-06-16 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-06-16 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2023-06-15 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-06-15 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-06-15 |
Time |
11:04 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy