Plan Review Details - Permit 23051233
Plan Review Stops For Permit 23051233 |
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-09 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-09 |
Time |
12:21 |
Sent To |
|
|
Notes |
2023-06-09 13:17:01 | 2ND REVIEW FBC-2020 RES. GAS | | PERMIT- 23051233 | | 6/9/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) GAS RISER: DUE TO THE INCREASED BTUH LOAD OF THE | | GENERATOR, THE 3/4-INCH PE PIPE MUST BE INCREASED TO | | 1-INCH FROM THE METER TO THE TEE AT THE WATER HEATER- | | TABLE G2413.8 [402.4(22)] FBC RES & FBC FG. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-30 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-30 |
Time |
16:29 |
Sent To |
|
|
Notes |
2023-05-30 16:46:22 | 1ST REVIEW FBC-2020 RES. GAS | | PERMIT- 23051233 | | 5/30/23 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SUBMIT A REVISED GAS RISER WITHOUT THE CITY | | APPROVAL STAMP ON IT. AN ORIGINAL DRAWING IS REQUIRED- | | SEC. 107.2.1 WPB. | | | | A) ON THE LEFT SIDE OF THE DRAWING PLEASE REVISE THE | | NEW GENERATOR BTU LOAD (486,000) AND THE TOTAL BTU LOAD | | (790,000). | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2023-06-09 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-06-08 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2023-05-30 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-05-25 |
Time |
13:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-09 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-09 |
Time |
12:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-30 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-30 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-09 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-09 |
Time |
13:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-05-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-05-30 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-05-30 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
|