Plan Review Details - Permit 23051030
Plan Review Stops For Permit 23051030
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-06-23 Cont ID  
Sent By rmcphers Date 2023-06-23 Time 14:51 Rev Time 0.00
Received By rmcphers Date 2023-06-23 Time 14:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-06-15 Cont ID  
Sent By rmcphers Date 2023-06-15 Time 14:30 Rev Time 0.00
Received By rmcphers Date 2023-06-15 Time 14:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-25 Cont ID  
Sent By rmcphers Date 2023-05-25 Time 10:00 Rev Time 0.00
Received By rmcphers Date 2023-05-25 Time 10:00 Sent To  
Notes
2023-05-25 10:01:03MANUFACTURED BUILDING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) UNABLE TO FIND THE PLANS ON THE STATE WEB SITE -
 PLEASE PROVIDE THE FLORIDA STATE PLAN TRACKING NUMBER -
 FBC 107.3 (1)
  
 2) PLEASE PROVIDE A FOUNDATION AND BUILDING TIE DOWN
 DRAWING SIGNED AND SEALED BY A DESIGN PROFESSIONAL -
 FBC 107.3 (1)
  
 3) THE MANUFACTURED BUILDING DRAWINGS APPROVAL FROM THE
 STATE HAS EXPIRED PER - FBC 107.3 (1) --- FAC 61-41.009
 (6) PLAN APPROVAL EXPIRATION - UPON REVISION OF THE
 BUILDING CODES ADOPTED HEREIN, PLAN APPROVALS SHALL
 EXPIRE UPON THE EFFECTIVE DATE OF THE REVISIONS UNLESS
 THE MANUFACTURER FILES WITH THE DEPARTMENT A SWORN
 STATEMENT BY AN AGENCY THAT THE PLANS AS PREVIOUSLY
 APPROVED HAVE BEEN REVIEWED AND ARE IN COMPLIANCE WITH
 THE REVISIONS TO THE ADOPTED CODES.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-06-26 Cont ID  
Sent By mpeterso Date 2023-06-26 Time 08:30 Rev Time 0.00
Received By mpeterso Date 2023-06-26 Time 08:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-05-24 Cont ID  
Sent By mpeterso Date 2023-05-24 Time 10:53 Rev Time 0.00
Received By mpeterso Date 2023-05-24 Time 10:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2023-06-28 Cont ID  
Sent By pleduc Date 2023-06-28 Time   Rev Time 0.00
Received By pleduc Date 2023-06-28 Time 09:00 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-06-09 Cont ID  
Sent By pleduc Date 2023-06-09 Time   Rev Time 0.00
Received By pleduc Date 2023-06-09 Time 15:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-05-24 Cont ID  
Sent By pleduc Date 2023-05-24 Time   Rev Time 0.00
Received By pleduc Date 2023-05-24 Time 11:43 Sent To  
Notes
2023-05-24 11:43:17THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE IS AN INDICATION OF A MODULE UNIT WITH A
 PROPOSED USE AS AN EDUCATIONAL OCCUPANCY, HOWEVER,
 THERE IS NO INDICATION OF A FIRE SPRINKLER PROTECTION,
  
 PER NFPA 101, CH 14, NEW EDUCATIONAL OCCUPANCIES.
  
 14.3.5 EXTINGUISHMENT REQUIREMENTS.
  
 14.3.5.1 EDUCATIONAL OCCUPANCY BUILDINGS SHALL BE
 PROTECTED THROUGHOUT
 BY AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM
 IN ACCORDANCE
 WITH SECTION 9.7 EXCEPT AS OTHERWISE PERMITTED BY
 14.3.5.2.
 14.3.5.2 THE REQUIREMENT OF 14.3.5.1 SHALL NOT APPLY TO
 ANY OF THE
 FOLLOWING:
 (1) NON-RELOCATABLE BUILDINGS HAVING AN AREA NOT
 EXCEEDING 1000 FT2
 (93 M2
 )
 (2) NON-RELOCATABLE BUILDINGS CONTAINING A SINGLE
 CLASSROOM
 (3) RELOCATABLE BUILDINGS COMPLYING WITH ALL OF THE
 FOLLOWING:
 (A) BUILDING AREA DOES NOT EXCEED 1000 FT2
 (93 M2
 )
 (B) BUILDING CONTAINS A SINGLE CLASSROOM
 (C) BUILDING IS LOCATED NOT LESS THAN 30 FT (9.1 M)
 FROM ANOTHER
 BUILDING
 14.3.5.3 EVERY PORTION OF EDUCATIONAL BUILDINGS BELOW
 THE LEVEL OF EXIT
 DISCHARGE SHALL BE PROTECTED THROUGHOUT BY AN APPROVED,
 SUPERVISED
 AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION
 9.7.
  
 PLEASE REVIEW AND PROVIDE AN APPLICABLE NOTE OF
 ACKNOWLEDGMENT TO PROVIDE A SEPARATE PERMIT & SHOP
 DRAWINGS.
  
  
  
 2) THERE IS AN INDICATION OF A MODULE UNIT WITH A
 PROPOSED USE AS AN EDUCATIONAL OCCUPANCY, HOWEVER,
 THERE IS NO INDICATION OF A FIRE ALARM PROTECTION.
  
 PER NFPA 101, CH 14, NEW EDUCATIONAL OCCUPANCIES.
  
 14.3.4 DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.
 14.3.4.1 GENERAL.
 14.3.4.1.1 EDUCATIONAL OCCUPANCIES SHALL BE PROVIDED
 WITH A FIRE ALARM
 SYSTEM IN ACCORDANCE WITH SECTION 9.6.
 14.3.4.1.2 THE REQUIREMENT OF 14.3.4.1.1 SHALL NOT
 APPLY TO BUILDINGS
 MEETING ALL OF THE FOLLOWING CRITERIA:
 (1) BUILDINGS HAVING AN AREA NOT EXCEEDING 1000 FT2
 (93 M2
 )
 (2) BUILDINGS CONTAINING A SINGLE CLASSROOM
 (3) BUILDINGS LOCATED NOT LESS THAN 30 FT (9.1 M) FROM
 ANOTHER
 BUILDING
  
 PLEASE REVIEW AND PROVIDE AN APPLICABLE NOTE OF
 ACKNOWLEDGMENT TO PROVIDE A SEPARATE PERMIT & SHOP
 DRAWINGS.
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-29 Cont ID  
Sent By dbattles Date 2023-06-29 Time 09:56 Rev Time 0.00
Received By dbattles Date 2023-06-09 Time 14:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-07 Cont ID  
Sent By hmoser Date 2023-06-07 Time 13:20 Rev Time 0.00
Received By lmarchan Date 2023-05-23 Time 08:55 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-07-12 Cont ID  
Sent By aoliver Date 2023-07-12 Time 18:54 Rev Time 0.00
Received By aoliver Date 2023-07-07 Time 11:53 Sent To  
Notes
2023-07-12 18:53:13NO IMPACT FEES DUE, SEE EMAIL UPLOADED
2023-07-07 11:53:517/7/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-05-25 Cont ID  
Sent By rmcphers Date 2023-05-25 Time 10:02 Rev Time 0.00
Received By rmcphers Date 2023-05-25 Time 10:02 Sent To  
Notes
2023-05-25 10:02:52PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2023-05-31 Cont ID  
Sent By hmoser Date 2023-05-31 Time 10:40 Rev Time 0.00
Received By hmoser Date 2023-05-31 Time 10:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-06-23 Cont ID  
Sent By ccole Date 2023-06-23 Time 12:57 Rev Time 0.00
Received By ccole Date 2023-06-23 Time 12:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-06-12 Cont ID  
Sent By ccole Date 2023-06-12 Time 10:06 Rev Time 0.00
Received By ccole Date 2023-06-12 Time 10:06 Sent To  
Notes
2023-06-12 10:07:312ND REVIEW FBC-2020 PLUMBING
 PERMIT- 23051030
 6/12/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) IN RESPONSE TO THE 1ST REVIEW COMMENTS CONCERNING
 WATER SERVICE AND SANITARY FACILITIES THE ARCHITECT IS
 STATING THE MODULE UNITS ARE "DRY" UNITS THAT THE
 STUDENTS WILL USE THE FACILITIES IN THE SOUTH BUILDING.
 IN ORDER TO VERIFY THE REQUIRED NUMBER OF PLUMBING
 FIXTURES WILL BE PROVIDED PLEASE PROVIDE FIXTURE
 CALCULATIONS FOR THE COMBINED STUDENT AND STAFF
 OCCUPANT LOAD OF THE TEMPORARY MODULE UNITS AND THE
 SOUTH BUILDING- SEC. 108.2 WPB, SEC. 403.3 & TABLE
 403.1 FBC P. PROVIDE A SCHEDULE THAT INDICATES THE
 REQUIRED NUMBER OF FIXTURES AND THE EXISTING NUMBER OF
 FIXTURES IN THE SOUTH BUILDING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-05-24 Cont ID  
Sent By ccole Date 2023-05-24 Time 11:48 Rev Time 0.00
Received By ccole Date 2023-05-24 Time 11:48 Sent To  
Notes
2023-05-24 11:48:481ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23051030
 5/24/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) AS-002 SITE PLAN: PROVIDE POTABLE WATER SERVICE LINE
 DETAILS FOR THE TEMPORARY MODULAR CLASSROOM UNIT- SECS.
 301.4, 602.1, 602.2, & 605.3 FBC P. SHOW THE TYPE AND
 SIZE OF SERVICE LINE, SERVICE LINE RUN, POINT OF
 CONNECTION TO THE CITY MAIN, AND THE LOCATIONS OF THE
 WATER METER AND BACKFLOW PREVENTER. INDICATE THE TYPE
 AND SIZE OF BACKFLOW PREVENTER TO BE INSTALLED- SEC.
 608.3 FBC P AND SEC. E WPB UTILITIES CROSS CONNECTION
 MANUAL. PLEASE NOTE A SEPARATE PLUMBING OR CIVIL PLAN
 MAY SUBMITTED AS ALTERNATES TO REVISING THE SITE PLAN-
 SEC. 107.2.1 WPB.
 A) CONCERNING THE BACKFLOW PREVENTER PLEASE NOTE A
 PERMIT APPLICATION SHALL BE SUBMITTED FOR THE
 INSTALLATION PRIOR TO APPROVAL OF THE PLUMBING PLAN
 REVIEW. YOU CAN SUBMIT AN APPLICATION TBD (TO BE
 DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY
 EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected]. YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT GENERATED, NOTIFY ME VIA EMAIL AND I WILL CHANGE
 THE REVIEW STATUS TO PASS.
  
 2) AS-002 SITE PLAN: PROVIDE A SANITARY DRAINAGE PLAN
 FOR THE MODULAR UNIT- SEC 701.2 & 701.3 FBC P. PROVIDE
 EITHER A DIRECT PIPE CONNECTION TO THE CITY SEWER LINE
 OR AN ONSITE SYSTEM SUCH AS A HOLDING TANK WITH
 PUMP-OUT CAPABILITY.
 A) SEWER CONNECTION- SHOW THE TYPE AND SIZE OF BUILDING
 DRAIN PIPE, THE DRAIN PIPE RUN, POINT OF CONNECTION TO
 THE SEWER LINE, AND CLEANOUT LOCATIONS.
 B) PUMP TANK- SHOW THE LOCATION OF THE TANK ON THE
 PLAN, PROVIDE A PIPING DIAGRAM, AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2023-06-29 Cont ID  
Sent By dbattles Date 2023-06-29 Time 09:55 Rev Time 0.00
Received By dbattles Date 2023-06-29 Time 09:55 Sent To  
Notes
2023-06-29 09:56:29DOCUMENTS APROVED IN MASTER PERMIT 23050901

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-06-23 Cont ID  
Sent By rmcphers Date 2023-06-23 Time 14:52 Rev Time 0.00
Received By rmcphers Date 2023-06-23 Time 14:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-06-15 Cont ID  
Sent By rmcphers Date 2023-06-15 Time 14:30 Rev Time 0.00
Received By rmcphers Date 2023-06-15 Time 14:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-05-25 Cont ID  
Sent By rmcphers Date 2023-05-25 Time 10:03 Rev Time 0.00
Received By rmcphers Date 2023-05-25 Time 10:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-06-28 Cont ID  
Sent By llouie Date 2023-06-28 Time   Rev Time  
Received By llouie Date 2023-06-28 Time   Sent To  
Notes
2023-06-28 09:17:11** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR IN ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE PROPOSED SCOPE OF WORK REQUIRES A DEVELOPMENT
 OF SIGINIFICANT IMPACT (DSI) AMENDMENT, TO BE REVEIWED
 AND APPROVED BY THE DEVELOPOMENT SERVICES
 DEPARTMENT-PLANNING DIVISION PRIOR TO BUILDING PERMIT.
 PLEASE CONTACT PLANNING STAFF FOR MORE INFORMATION.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTATC LINDA LOUIE @ 561.822.1458 IF THERE ARE
 QUESTIONS.
  
 * REFERENCE: CARDINAL NEWMAN DSI (PB 1489).
  