Plan Review Stops For Permit 23050966 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2023-06-14 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2023-06-14 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2023-06-14 |
Time |
11:50 |
Sent To |
|
|
Notes |
2023-06-14 11:52:28 | CONFLICTING ADDRESSES SUBMITTED, THE PLANS LIST 595 S | | ROSEMARY AVE SUITE 575A AND THE PERMIT APPLICATION | | LISTS 635 HIBISCUS STREET SUITE 575A. ALL THE ADDRESSES | | FOR THIS SITE ARE NEWLY CREATED, NO SUITE HAS AN | | ADDRESSES OF 575A, PLEASE CONTACT [email protected] | | OR CALL 561-805-6659 TO DISCUSS THE ADDRESSING ISSUES. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
N |
Date |
2023-06-22 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-22 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-22 |
Time |
10:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-22 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-22 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-06-09 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-06-09 |
Time |
09:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-06-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-06-09 |
Time |
09:24 |
Sent To |
|
|
Notes |
2023-06-09 14:36:44 | FIRE PROVISO: | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | DRAWINGS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-07-19 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-07-19 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-06-08 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2023-06-22 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-06-22 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-06-22 |
Time |
10:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2023-06-22 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-06-22 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-06-22 |
Time |
07:40 |
Sent To |
|
|
Notes |
2023-06-22 10:07:00 | PLAN DENIED | | 1) PROVIDE OUTDOOR AIR CALCULATIONS TO MEET | | TABLE 403.1.1 FBC (M) 2020 | | 2) NOT SHOWING DUCTWORK ON UNITS 2, 3, OR 4 | | PLEASE EXPLAIN WHY. SECTION 107 FBC. | | 3) PLEASE LABEL ALL ROOMS FOR THIS REVIEW. | | 107 FBC | | 4) REFER TO SECTION C403.2.1 CALCULATIONS | | OF HEATING AND COOLING LOADS. FBC (ENERGY) | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-06-09 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-06-09 |
Time |
10:11 |
Sent To |
|
|
Notes |
2023-06-09 12:08:07 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 23050966 | | 6/9/23 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020FS- | | FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) P-001: A SERVICE SINK IS A REQUIRED FIXTURE FOR M | | OCCUPANCIES- TABLE 403.1 FBC P. PLEASE SHOW THE | | LOCATION OF THE SINK. | | | | 2) SHEET P-201: SHOW THE SOURCE OF THE HOT WATER- SEC. | | 607.1 FBC P. | | | | 3) P-201: SHOW THE LOCATIONS OF THE METER AND THE PIPE | | CAP LOCATION- SEC. 107.2.1 WPB. | | | | 4) P-201: SHOW THE MEANS OF PROVIDING TEMPERED WATER | | DELIVERY FROM THE LAVATORY- SECS. 419.5 & 607.1.2 FBC | | P. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-06-09 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-06-09 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2023-07-18 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2023-07-18 |
Time |
16:58 |
Rev Time |
0.75 |
Received By |
eschneid |
Date |
2023-07-18 |
Time |
16:58 |
Sent To |
|
|
Notes |
2023-07-18 17:33:41 | FAILED | | | | 1) THE INSTALLATION OF THE NEW ALUMINUM METAL PANEL AT | | THE ENTRY DOOR TRANSOM REDUCES THE AMOUNT OF GLAZING | | ALONG THE EASTERN STOREFRONT. PROVIDE VERIFICATION THAT | | THE MINIMUM PERCENTAGE OF GLAZING (50 PERCENT OF THE | | FRONTAGE) IS STILL BEING PROVIDED. | | | | 2) SHEET S-002 SHOWS A STAIR DETAIL. WHERE IS THIS TO | | BE LOCATED AS THE FLOOR PLANS DO NOT SHOW A STAIR? | | PLEASE NOTE, NO MEZZANINE IS PERMITTED IN THIS UNIT. | | | | CONTACT ERIC SCHNEIDER @ 561-822-1446 | | [email protected] | | |
|
|