Plan Review Details - Permit 23050901
Plan Review Stops For Permit 23050901
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2023-07-10 Cont ID  
Sent By rmcphers Date 2023-07-10 Time 14:16 Rev Time 0.00
Received By rmcphers Date 2023-07-10 Time 14:16 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2023-06-15 Cont ID  
Sent By rmcphers Date 2023-06-15 Time 14:53 Rev Time 0.00
Received By rmcphers Date 2023-06-15 Time 14:53 Sent To  
Notes
2023-06-15 14:53:36AN ASBESTOS SURVEY IS NOT REQUIRED - PLEASE PROVIDE A
 SIGNED ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON
 LETTERHEAD, STATING THAT THE INSTRUCTIONS ON THE
 WEBSITE OF ASBESTOS PROGRAM COORDINATOR, FLORIDA
 DEPARTMENT OF HEALTH PALM BEACH COUNTY WILL BE
 FOLLOWED, AND THAT NOTIFICATION WILL BE GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-05-23 Cont ID  
Sent By rmcphers Date 2023-05-23 Time 14:37 Rev Time 0.00
Received By rmcphers Date 2023-05-23 Time 14:36 Sent To  
Notes
2023-05-23 14:37:27AN ASBESTOS SURVEY IS NOT REQUIRED - PLEASE PROVIDE A
 SIGNED ACKNOWLEDGEMENT FROM THE CONTRACTOR, ON
 LETTERHEAD, STATING THAT THE INSTRUCTIONS ON THE
 WEBSITE OF ASBESTOS PROGRAM COORDINATOR, FLORIDA
 DEPARTMENT OF HEALTH PALM BEACH COUNTY WILL BE
 FOLLOWED, AND THAT NOTIFICATION WILL BE GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-07-21 Cont ID  
Sent By rmcphers Date 2023-07-21 Time 09:28 Rev Time 0.00
Received By rmcphers Date 2023-07-21 Time 09:28 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-06-15 Cont ID  
Sent By rmcphers Date 2023-06-15 Time 15:04 Rev Time 0.00
Received By rmcphers Date 2023-06-15 Time 14:53 Sent To  
Notes
2023-06-15 15:03:07REMODEL AND ENTRY ADDITIONS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE THE FLORIDA STATE PRODUCT APPROVAL
 FRONT PAGES OF THE PRODUCT APPROVALS FOR PRODUCT
 APPROVALS - FL16554, FL14218, FL12400 - FBC WPB 107.1
  
 2) THE DRAWINGS SHOW PRODUCT APPROVAL (NOA 20-0401.14)
 TO BE USED - THE PROVIDED PRODUCT APPROVAL NOA
 20-0401.10 NEEDS TO BE REVIEWED AND MARKED APPROVED BY
 THE DESIGNER OF RECORD FBC WPB 107.3.4
  
 3) DRAWING A-700 NEEDS TO BE REVISED TO SHOW THE
 RESTROOM CEILING CHANGE - PLEASE SHOW THE RESTROOM
 CEILINGS TO BE IMPERVIOUS - FBC 468.3.5.10 CEILINGS.
 CEILINGS IN GROUP TOILET ROOMS, KITCHENS, SCULLERIES,
 CAN WASH AREAS, SHOWERS AND LOCKER ROOMS SHALL BE
 IMPERVIOUS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-23 Cont ID  
Sent By rmcphers Date 2023-05-23 Time 14:59 Rev Time 0.00
Received By rmcphers Date 2023-05-23 Time 08:54 Sent To  
Notes
2023-05-23 14:36:29REMODEL AND ENTRY ADDITIONS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE NEW EXTERIOR WINDOWS, DOORS
 AND ROOFING SYSTEMS - ALL PRODUCT APPROVALS NEED TO BE
 REVIEWED AND MARKED APPROVED BY THE BUILDING DESIGNER
 OF RECORD OR BE LISTED ON THE DRAWINGS BY THE PERMIT
 NUMBER - FBC 107.3.4
  
 EXTERIOR WINDOW, DOOR AND ROOFING SYSTEM PRODUCT
 APPROVALS MAY BE DEFERRED SUBMITTALS BY LISTING ITEMS
 TO BE DEFERRED ON THE CONSTRUCTION DOCUMENTS - FBC
 WPB107.3.4.1
  
 2) THE LIFE SAFETY DRAWINGS SHOW FIRE RATED WALLS AND
 POSSIBLE SMOKE RATED WALLS - PLEASE PROVIDE A LEGEND TO
 CLARIFY THE MARKINGS ON THE LIFE SAFETY DRAWINGS - FBC
 107.2.1
  
 3) DOOR NUMBER 201 SHOULD BE FIRE RATED - IT IS SHOWN
 AS NOT FIRE RATED ON THE DOOR SCHEDULE FBC 716
  
 4) PLEASE SHOW THE RESTROOM CEILINGS TO BE IMPERVIOUS -
 FBC 468.3.5.10 CEILINGS.
 CEILINGS IN GROUP TOILET ROOMS, KITCHENS, SCULLERIES,
 CAN WASH AREAS, SHOWERS AND LOCKER ROOMS SHALL BE
 IMPERVIOUS.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-07-17 Cont ID  
Sent By mpeterso Date 2023-07-17 Time 10:20 Rev Time 0.00
Received By mpeterso Date 2023-07-17 Time 10:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-06-12 Cont ID  
Sent By mpeterso Date 2023-06-12 Time 11:29 Rev Time 0.00
Received By mpeterso Date 2023-06-12 Time 10:55 Sent To  
Notes
2023-06-12 11:32:23ELECTRIC REVIEW FAILED
  
 1) ONE LINE RISER DIAGRAM ON SHEET E-401 DOES NOT
 DETAIL PANEL 2NH. PLEASE CORRECT AS APPLICABLE. NEC
 215.5
  
 2 )PLEASE PROVIDE A NOTE ON SHEET E-101 THAT CAMPUS
 MAIN ELECTRIC ROOM IS TO COMPLY WITH ALL APPLICABLE
 REQUIREMENTS IN ACCORDANCE WITH NEC 110.26 "SPACES
 ABOUT ELECTRICAL EQUIPMENT" WITH SPECIAL ATTENTION TO
 LARGE EQUIPMENT AND EGRESS REQUIREMENTS
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-05-24 Cont ID  
Sent By mpeterso Date 2023-05-24 Time 09:46 Rev Time 0.00
Received By mpeterso Date 2023-05-23 Time 10:13 Sent To  
Notes
2023-05-24 09:48:22ELECTRIC REVIEW FAILED
  
 PLEASE PROVIDE A NARRATIVE RESPONSE IN ADDITION TO ANY
 PLAN CHANGES TO EACH OF THE FOLLOWING COMMENTS:
  
 1) ELECTRICAL WORK SCOPE IS NOT CLEAR. PLEASE PROVIDE A
 NARRATIVE AS WELL AS PLANS INDICATING PROPOSED AND
 EXISTING WORK, INCLUDING ALL TYPE AND LOCATIONS WHERE
 WORK IS TO BE PERFORMED. I.E. NEW SWITCHGEAR AND PANEL
 BOARDS, DUCT BANKS. FBC 107.2 NEC 215.5
  
 2) SITE PLAN INDICATES NO WORK CAMPUS MAIN ELECTRIC
 ROOM. HOWEVER, IT APPEARS A NEW MAIN SWITCH BOARD IS TO
 BE INSTALLED IN THIS BUILDING. PLEASE CORRECT OR
 PROVIDE ADDITIONAL CLARITY ON EQUIPMENT LOCATIONS. IN
 ADDITION, IT APPEARS THIS CAMPUS MAIN ELECTRIC ROOM IS
 LOCATED IN A MAINTENANCE BUILDING, HOWEVER THERE IS NO
 LOCATION GIVEN FOR THIS BUILDING ON SITE PLAN. LOCATION
 DESIGNATIONS IN MANY AREAS ARE NOT CLEAR. FBC 107.2
  
 3) PLEASE USE THE PROPER IDENTIFYING NAMES ON ALL PLANS
 FOR ELECTRICAL EQUIPMENT. I.E. NOTE 4 ON SITE PLAN,
 MAIN ELECTRIC PANEL SHOULD BE CORRECTLY IDENTIFIED WITH
 PANEL DESIGNATION. FBC 107.2
  
 4) PROVIDE A MAIN ELECTRICAL ROOM FLOOR PLAN AS
 REFERENCED BY NOTE 1 ON SHEET E-401. FBC 107.2
  
 5) PLEASE INDICATE PURPOSE OF REFERRING TO SWBD AS MAIN
 1 OF 1. PLEASE PROVIDE CLARITY OF THE PURPOSE OF THIS
 DESIGNATION. FBC 107.2
  
 6) PLEASE PROVIDE ADDITIONAL CLARITY OF RISER DIAGRAM
 FOR MULTIPLE FEEDS TO MODULAR SWITCHBOARD. NEC 215.5
  
 7) PLEASE ADD A NOTE STATING SEPARATE PERMITS ARE
 REQUIRED FOR ALL LOW VOLTAGE SYSTEMS SUCH AS BUT NOT
 LIMITED TO, FIRE ALARM, VOICE, DATA, SECURITY, ACCESS
 CONTROL ETC.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2023-07-17 Cont ID  
Sent By cseifer Date 2023-07-17 Time 12:01 Rev Time 0.00
Received By cseifer Date 2023-07-17 Time 12:01 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2023-07-13 Cont ID  
Sent By parking Date 2023-07-13 Time 13:11 Rev Time 0.00
Received By cseifer Date 2023-07-13 Time 13:10 Sent To  
Notes
2023-07-13 13:11:20UNDER FORMAL ENGINEERING REVIEW.
  
 THANKS,
 CHLOE SEIFER, PROJECT COORDINATOR, ENGINEERING SERVICES
 DEPARTMENT, [email protected], 561-494-1098
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2023-07-18 Cont ID  
Sent By pleduc Date 2023-07-18 Time   Rev Time 0.00
Received By pleduc Date 2023-07-18 Time 10:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-06-12 Cont ID  
Sent By pleduc Date 2023-06-12 Time   Rev Time 0.00
Received By pleduc Date 2023-06-12 Time 11:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-05-25 Cont ID  
Sent By pleduc Date 2023-05-25 Time   Rev Time 0.00
Received By pleduc Date 2023-05-25 Time 09:53 Sent To  
Notes
2023-05-25 12:46:31THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) SHEET A 402 & A 600 - THERE IS AN INDICATION OF DOOR
 201 AS BEING SMOKE RATED YET OTHER DOORS IN THE
 STAIRWELLS INCLUDING DOOR 220 AS BEING 45 MINUTE.
  
 PER NFPA 101, CH 14 EDUCATIONAL OCCUPANCIES.
  
 7..2.2.5 ENCLOSURE AND PROTECTION OF STAIRS
  
 7.2.2.5.1 ENCLOSURES
  
 7.2.2.5.1.1 ALL INSIDE STAIRS SERVING AS AN EXIT OR
 EXIT COMPONENT SHALL
 BE ENCLOSED IN ACCORDANCE WITH 7.1.3.2
  
 7.1.3.2 EXITS.
  
 7.1.3.2.1 WHERE THIS CODE REQUIRES AN EXIT TO BE
 SEPARATED FROM OTHER
 PARTS OF THE BUILDING, THE SEPARATING CONSTRUCTION
 SHALL MEET THE REQUIRE MENTS OF SECTION 8.2 AND THE
 FOLLOWING:
 (1)* THE SEPARATION SHALL HAVE A MINIMUM 1-HOUR FIRE
 RESISTANCE RATING
 WHERE THE EXIT CONNECTS THREE OR FEWER STORIES
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC CODE
 REFERENCES.
  
  
  
 1A) SHEET A 402 & A 600 - THERE ARE INDICATIONS OF NEW
 WALLS WITHIN THE STAIRWAYS SUPPORTING DOORS 201 AND 220
 THAT DO NOT APPEAR TO BE 1 - HR RATED AS REQUIRED
 PER THE CH 14 FIRE CODES ABOVE.
  
 PLEASE REVIEW AND PROVIDE FOR LISTED 1 HR FIRE RATED
 WALLS.
  
  
  
 2) LIFE SAFETY SHEETS - THERE IS AN INDICATION OF
 CLASSROOM DOORS OPENING OUT INTO THE CORRIDOR.
  
 PER NFPA 101, CH 14
  
 14.2.3.2 MINIMUM CORRIDOR WIDTH.
 14.2.3.2.1 EXIT ACCESS CORRIDORS SHALL HAVE NOT LESS
 THAN 6 FT (1830 MM)
 OF CLEAR WIDTH EXCEPT AS OTHERWISE PERMITTED IN
 14.2.3.2.2.
  
 NARRATIVE EXPLANATION: THE TERM CLEAR WIDTH MEANS A 6
 FT (1830 MM) WIDE CLEAR
 SPACE WITH NO OBSTRUCTIONS OTHER THAN THOSE PERMITTED
 BY 7.3.2.2
 AND DOORS AS PERMITTED BY 7.2.1.4.3. SUBSECTION 7.3.2
 DETAILS THE
 REQUIRED METHOD FOR MEASURING THE WIDTH OF A COMPONENT
 OF THE
 MEANS OF EGRESS. PARAGRAPH 7.3.2.2 PERMITS PROJECTIONS
 OF NOT
 MORE THAN 4 1???2 IN. (114 MM) ON EACH SIDE OF THE
 CORRIDOR. THE PROJECTIONS
 ARE PERMITTED TO BE LOCATED AT OR BELOW A HANDRAIL
 HEIGHT
 OF 38 IN. (965 MM), AND THE MAXIMUM 4 1???2 IN. (114
 MM)
 ENCROACHMENT IS TO BE IGNORED WHEN DETERMINING WIDTH
 FOR USE
 IN EGRESS CAPACITY CALCULATIONS
  
 7.2.1.4.3* DOOR LEAF ENCROACHMENT.
  
 A.7.2.1.4.3 THE REQUIREMENTS OF 7.2.1.4.3 ARE NOT
 INTENDED TO APPLY TO
 THE SWING OF CROSS-CORRIDOR DOORS, SUCH AS SMOKE
 BARRIER DOORS AND
 HORIZONTAL EXITS. NEITHER ARE THE REQUIREMENTS INTENDED
 TO APPLY TO DOORS
 FROM ROOMS THAT ARE TYPICALLY UNOCCUPIED, SUCH AS
 JANITOR???S CLOSETS,
 ELECTRICAL CLOSETS, OR TELECOMMUNICATIONS CLOSETS
  
 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL
 LEAVE NOT LESS THAN ONE-HALF OF THE REQUIRED WIDTH OF
 AN AISLE, A CORRIDOR,
 A PASSAGEWAY, OR A LANDING UNOBSTRUCTED, UNLESS BOTH OF
 THE FOLLOWING
 CONDITIONS ARE MET:
 (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN
 EXISTING
 BUILDING.
 (2) THE DOOR OPENING MEETS THE REQUIREMENT OF
 7.2.1.4.3.2.
  
 7.2.1.4.3.2 WHEN FULLY OPEN, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL
 NOT PROJECT MORE THAN 7 IN. (180 MM) INTO THE REQUIRED
 WIDTH OF AN AISLE,
 A CORRIDOR, A PASSAGEWAY, OR A LANDING, UNLESS THE DOOR
 LEAF IS EQUIPPED
 WITH AN APPROVED SELF-CLOSING DEVICE AND IS NOT
 REQUIRED BY THE PROVI SIONS
 OF 7.2.1.4.2 TO SWING IN THE DIRECTION OF EGRESS TRAVEL
  
  
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC CODE
 REFERENCES.
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By aoliver Date 2023-07-07 Time 11:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-26 Cont ID  
Sent By aoliver Date 2023-06-26 Time 09:32 Rev Time 0.00
Received By aoliver Date 2023-05-18 Time 16:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-09 Cont ID  
Sent By lmarchan Date 2023-06-09 Time 09:41 Rev Time 0.00
Received By shill Date 2023-05-18 Time 09:35 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-05-23 Cont ID  
Sent By rmcphers Date 2023-05-23 Time 14:37 Rev Time 0.00
Received By rmcphers Date 2023-05-23 Time 14:37 Sent To  
Notes
2023-05-23 14:38:09PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-06-14 Cont ID  
Sent By hmoser Date 2023-06-14 Time 13:15 Rev Time 0.00
Received By hmoser Date 2023-06-14 Time 06:53 Sent To  
Notes
2023-06-14 13:15:09PLAN DENIED
 REFER TO TABLE 403.3.1.1 MINIMUM VENTILATION RATES
 PROVIDE OUTDOOR CALCULATIONS ON PLAN 2020 FBC (M)
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-05-31 Cont ID  
Sent By hmoser Date 2023-05-31 Time 11:22 Rev Time 0.00
Received By hmoser Date 2023-05-31 Time 11:05 Sent To  
Notes
2023-05-31 11:21:26NO PLAN SUBMITTED FOR CHILLER OR DUCT WORK.
 REFER TO SHEET M-001 IN SUPPORTING DOCS.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status F Date 2023-07-19 Cont ID  
Sent By ccole Date 2023-07-19 Time 16:53 Rev Time 0.00
Received By ccole Date 2023-07-19 Time 15:34 Sent To  
Notes
2023-07-19 17:03:223RD REVIEW FBC-2020 PLUMBING
 PERMIT- 23050901
 7/19/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. COMMENT #2 FROM THE 1ST
 AND 2ND REVIEWS COPIED BELOW HAS NOT BEEN RESOLVED.
  
 2) P-001, P-202, P-204, & P-302: REFER TO 468.3.5.6 FBC
 B AND PROVIDE HOSE BIBS IN EACH MALE AND FEMALE GROUP
 TOILET ROOM.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-06-12 Cont ID  
Sent By ccole Date 2023-06-12 Time 08:07 Rev Time 0.00
Received By ccole Date 2023-06-09 Time 13:45 Sent To  
Notes
2023-06-12 08:07:572ND REVIEW FBC-2020 PLUMBING
 PERMIT- 23050901
 6/9/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED C0MMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES.
  
 1) COMMENT #1 FROM THE 1ST REVIEW FAILED.
  
 A) THE NEW FIXTURE CALCULATIONS ON SHEET A-101 DO NOT
 INCLUDE THE BUSINESS OCCUPANCY REQUIREMENTS.
  
 B) BASED ON TABLE 403.1 A TOTAL OF (4) HI-LO DRINKING
 FOUNTAINS ARE REQUIRED. THE PLANS SHOW ONLY ONE HI-LO
 ON THE SECOND FLOOR PLEASE REFER TO SEC. 410.3 FBC P
 AND SEC. 211.2 FBC ACC. EACH OF THESE CODE SECTIONS
 REQUIRE THE HI-LO TYPE OF DRINKING FOUNTAIN. THE SINGLE
 FOUINTAIN WITH BOTTLE FILLER DOES NOT MEET COMPLIANCE
 WITH THE EXCEPTIONS LISTED UNDER THE SECTIONS.
  
 2) COMMENT #2 FROM THE 1ST REVIEW FAILED. SHEETS P-001,
 P-202, P-204, & P-302: A HOSE BIB IS SHOWN IN THE 2ND
 FLOOR GIRLS RESTROOM HOWEVER HOSE BIBS ARE NOT SHOWN IN
 THE OTHER GROUP RESTROOMS.
  
 3) COMMENT #4 FROM THE 1ST REVIEW FAILED. SHEETS P-001,
 P-202, P-204, & P-302: THE REQUIRED ASSE 1071 MIXING
 VALVE FOR THE EMERGENCY SHOWER AND EYE WASH STATIONS
 WAS NOT PROVIDED.
  
 7) COMMENT #7 FROM THE 1ST REVIEW FAILED. SHEET A-212:
 THE DIMENSIONS OF THE CLEAR FLOOR SPACES WERE NOT
 PROVIDED. THE DIMENSIONS OF THE AMBULATORY COMPARTMENTS
 WERE NOT PROVIDED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-05-24 Cont ID  
Sent By ccole Date 2023-05-24 Time 08:50 Rev Time 0.00
Received By ccole Date 2023-05-23 Time 13:15 Sent To  
Notes
2023-05-24 08:54:091ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23050901
 5/23/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET LS-101: PROVIDE THE OCCUPANT LOAD OF THE
 BUILDING AND PLUMBING FIXTURE CALCULATIONS IN
 ACCORDANCE WITH TABLE 403.1 FBC P. INDICATE THE
 REQUIRED AND PROVIDED NUMBER OF FIXTURES.
 A) THE PLANS SHOW NUMEROUS SINGLE DRINKING FOUNTAINS.
 PLEASE NOTE WHERE DRINKING FOUNTAINS ARE REQUIRED NOT
 FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH THE
 REQUIREMENTS FOR PEOPLE WHO USE A WHEELCHAIR AND ONE
 DRINKING FOUNTAIN SHALL COMPLY WITH THE REQUIREMENTS
 FOR STANDING PERSONS. PLEASE REFER TO EXCEPTION 1 WHICH
 ALLOWS A SINGLE FOUNTAIN WITH TWO SEPARATE HI AND LO
 SPOUTS TO MEET COMPLIANCE
  
 2) P-001, P-202, P-204, & P-302: REFER TO 468.3.5.6 FBC
 B AND PROVIDE HOSE BIBS IN EACH MALE AND FEMALE GROUP
 TOILET ROOM.
 A) VERIFY THE FLOORS ARE SLOPED TO THE FLOOR DRAINS IN
 THE GROUP TOILET ROOMS.
  
 3) P-001, P-202, P-204, & P-302: REFER TO SEC.
 468.3.5.1.2 FBC B AND VERIFY POINT OF USE MIXING VALVES
 SHALL BE INSTALLED AT ALL HANDWASH SINKS AND LAVATORIES
 TO LIMIT THE HOT WATER DELIVERY TEMPERATURE TO 110
 DEGREES F. PLEASE ADD THE LISTING NUMBERS OF THE VALVES
 SPECIFIED IN THE SCHEDULE.
  
 4) P-001, P-202, P-204, & P-302: PROVIDE AN ASSE 1071
 MIXING VALVE TO THE WATER SUPPLY LINES TO THE EMERGENCY
 SHOWER AND EYE WASH STATIONS IN ACCORDANCE WITH TO ISEA
 Z358.1 SPECIFICATIONS- SEC. 411.1 FBC P.
  
 5) P-201, P-203, P-302: BASED ON SEC. 803.1 FBC P THE
 DRAINAGE FROM THE LAB SINKS AND THE EMERGENCY SHOWERS
 AND EYEWASH STATIONS SHALL PASS THROUGH A DILUTION OR
 NEUTRALIZING DEVICE BEFORE DISCHARGING INTO THE
 SANITARY SYSTEM.
  
 6) P-402: THE UTILITY CONTROL DETAIL FOR THE SCIENCE
 CLASSROOMS APPEARS TO INDICATE NATURAL OR LP GAS
 SERVICE IS BEING PROVIDED TO THE ROOMS. PLEASE CLARIFY
 AND IF APPLICABLE PROVIDE GAS PLANS INCLUDING A RISER
 DIAGRAM, EQUIPMENT SPECIFICATIONS, COMBUSTION AIR
 CALCULATIONS AND APPLIANCE VENTING DIAGRAMS AND
 SPECIFICATIONS- SEC. 107.2.1 & 107.3.5.1.5 WPB.
  
 7) A-212: PROVIDE ENLARGED DIMENSIONED DRAWINGS OF THE
 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENTS SHOWING THE
 CLEAR FLOOR SPACE DIAGRAMS FOR THE FIXTURES- SECS.
 604.3 & 604.8 FBC ACC.
 A) PROVIDE THE DIMENSIONS AMBULATORY COMPARTMENTS AND
 ACCESSORY INSTALLATION DETAILS- SEC. 604.8.2- 604.8.2.3
 FBC ACC.
 B) SHOW THE CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS
 FOR THE REQUIRED ACCESSIBLE URINALS- SECS. 213.3.3 &
 605.3 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2023-06-21 Cont ID  
Sent By jbaker Date 2023-06-21 Time 14:23 Rev Time 0.00
Received By jbaker Date 2023-06-21 Time 14:23 Sent To  
Notes
2023-06-21 14:26:20[email protected]
  
 PROVIDE 553.791 REQUIRED COMPLETE NTBO PACKAGE
 INCLUDING RESUMES AND COI. PLEASE PROVIDE
 QUALIFICATIONS/RESUMES FOR INSPECTORS WITH THEIR
 LICENSES.
  
 PROVIDE VERBIAGE IN COI BLANK AT BOTTOM OF PAGE SIMILAR
 TO EXAMPLE BELOW:
  
 IN ACCORDANCE WITH SECTION 553.791(4)(B), (17), FLORIDA
 STATUTES, THERE IS PROFESSIONAL LIABILITY INSURANCE
 COVERAGE I PLACE WITH ___________ INSURANCE COMPANY FOR
 THE PRIVATE PROVIDER???S FIRM, THE PRIVATE PROVIDER,
 AND ANY AND ALL DULY AUTHORIZED REPRESENTATIVES IN THE
 AMOUNTS REQUIRED BY SECTION 553.791(17). THE POLICY IS
 A CLAIMS-MADE POLICY, FOR WHICH THE INSURED WILL
 MAINTAIN COVERAGE FOR A MINIMUM OF FIVE YEARS
 SUBSEQUENT TO THE BUILDING CODE INSPECTION SERVICES IN
 THE CITY OF WEST PALM BEACH, THE CARRIER IS AUTHORIZED
 TO DO BUSINESS IN THIS STATE, AND THE CARRIER HAS A
 MINIMUM A.M. BEST???S RATING OF A.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2023-07-10 Cont ID  
Sent By rmcphers Date 2023-07-10 Time 14:17 Rev Time 0.00
Received By rmcphers Date 2023-07-10 Time 14:17 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2023-06-15 Cont ID  
Sent By rmcphers Date 2023-06-15 Time 15:05 Rev Time 0.00
Received By rmcphers Date 2023-06-15 Time 15:05 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2023-05-23 Cont ID  
Sent By rmcphers Date 2023-05-23 Time 15:24 Rev Time 0.00
Received By rmcphers Date 2023-05-23 Time 15:24 Sent To  
Notes
2023-05-23 15:25:06SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-07-10 Cont ID  
Sent By rmcphers Date 2023-07-10 Time 14:19 Rev Time 0.00
Received By rmcphers Date 2023-07-10 Time 14:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-06-09 Cont ID  
Sent By shill Date 2023-06-09 Time 09:42 Rev Time 0.00
Received By shill Date 2023-06-09 Time 09:42 Sent To  
Notes
2023-06-09 09:43:10DIGITALLY SIGNED PLANS IN SIGNATURE FOLDER.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-05-23 Cont ID  
Sent By rmcphers Date 2023-05-23 Time 14:58 Rev Time 0.00
Received By rmcphers Date 2023-05-23 Time 14:58 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2023-07-19 Cont ID  
Sent By llouie Date 2023-07-19 Time   Rev Time 0.00
Received By llouie Date 2023-07-19 Time   Sent To  
Notes
2023-07-19 15:36:48** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR IN ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE PROPOSED SCOPE OF WORK REQUIRES A DEVELOPMENT
 OF SIGINIFICANT IMPACT (DSI) AMENDMENT, TO BE REVEIWED
 AND APPROVED BY THE DEVELOPOMENT SERVICES
 DEPARTMENT-PLANNING DIVISION PRIOR TO BUILDING PERMIT.
 PLEASE CONTACT PLANNING STAFF FOR MORE INFORMATION.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTATC LINDA LOUIE @ 561.822.1458 IF THERE ARE
 QUESTIONS.
  
 * REFERENCE: CARDINAL NEWMAN DSI (PB 1489).
  

Review Stop Z ZONING
Rev No 1 Status F Date 2023-06-26 Cont ID  
Sent By llouie Date 2023-06-26 Time   Rev Time  
Received By llouie Date 2023-06-26 Time   Sent To  
Notes
2023-06-26 08:30:22** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR IN ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE PROPOSED SCOPE OF WORK REQUIRES A DEVELOPMENT
 OF SIGINIFICANT IMPACT (DSI) AMENDMENT, TO BE REVEIWED
 AND APPROVED BY THE DEVELOPOMENT SERVICES
 DEPARTMENT-PLANNING DIVISION PRIOR TO BUILDING PERMIT.
 PLEASE CONTACT PLANNING STAFF FOR MORE INFORMATION.
  
  
 NOTES:
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTATC LINDA LOUIE @ 561.822.1458 IF THERE ARE
 QUESTIONS.
  
 * REFERENCE: CARDINAL NEWMAN DSI (PB 1489).
  