|
 |
 |
 |
 |
 |
Plan Review Details - Permit 23050727
Plan Review Stops For Permit 23050727 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:03 |
Sent To |
|
|
Notes |
2023-06-21 14:12:37 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) 1) SUBMIT GENERATOR PAD DRAWINGS WITH GENERATOR TO | | PAD ANCHORING DETAILS. IF A PREFABRICATED GENERATOR PAD | | WILL BE USED, SUBMIT SIGNED AND SEALED SITE SPECIFIC | | ENGINEERING FOR IT. FBC AMENDMENTS 107.2.1 | | | | 2) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | FEET FROM ANY OPENINGS INTO A BUILDING. SPECIFY THIS ON | | THE SURVEY. FBC-R303.5.1 INTAKE OPENINGS. MECHANICAL | | AND GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE | | LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM ANY | | HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | AND LOADING DOCKS. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2023-05-17 |
|
|
Cont ID |
|
Sent By |
jcooley |
Date |
2023-05-17 |
Time |
19:18 |
Rev Time |
0.00 |
Received By |
jcooley |
Date |
2023-05-17 |
Time |
18:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2023-05-18 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-18 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-18 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-05-15 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2023-05-18 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-18 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-18 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2023-06-21 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:03 |
Sent To |
|
|
Notes |
2023-06-21 14:20:56 | THE SIGNATURE WILL BE REVIEWED WHEN THE PAD AND | | ANCHORING DRAWINGS ARE SUBMITTED. | 2023-05-18 10:06:16 | GAS PAGE SIGNED BY CONTRACTOR |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2023-06-07 |
|
|
Cont ID |
|
Sent By |
gvolcy |
Date |
2023-06-07 |
Time |
17:21 |
Rev Time |
0.00 |
Received By |
avolcy |
Date |
2023-06-07 |
Time |
17:21 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |